4,619 research outputs found

    Retrospective correction of Rigid and Non-Rigid MR motion artifacts using GANs

    Full text link
    Motion artifacts are a primary source of magnetic resonance (MR) image quality deterioration with strong repercussions on diagnostic performance. Currently, MR motion correction is carried out either prospectively, with the help of motion tracking systems, or retrospectively by mainly utilizing computationally expensive iterative algorithms. In this paper, we utilize a new adversarial framework, titled MedGAN, for the joint retrospective correction of rigid and non-rigid motion artifacts in different body regions and without the need for a reference image. MedGAN utilizes a unique combination of non-adversarial losses and a new generator architecture to capture the textures and fine-detailed structures of the desired artifact-free MR images. Quantitative and qualitative comparisons with other adversarial techniques have illustrated the proposed model performance.Comment: 5 pages, 2 figures, under review for the IEEE International Symposium for Biomedical Image

    Motion-Corrected Simultaneous Cardiac PET-MR Imaging

    Get PDF

    Dual gated PET/CT imaging of heart

    Get PDF
    Coronary artery disease (CAD) resulting from atherosclerotic arterial changes, plaques, is a progressive process, which can be asymptomatic for many years. Asymptomatic CAD can cause a heart attack that leads to sudden death if the vulnerable coronary plaque ruptures and causes artery occlusion. The plaque inflammation plays an important role in the rupture susceptibility. Reliable anticipation of rupture is still clinically impossible for a single patient. Detection of the vulnerable coronary plaques before clinical signs remains a significant scientific challenge where positron emission tomography (PET) can play an important role. The aim of this dissertation was to find out whether a small, coronary plaque size, heart structures could be detected by a clinically available positron emission tomography and computed tomography (PET/CT) hybrid camera in realistically moving cardiac phantoms, a minipig model, and patients with CAD. Due to cardiac motions accurate detection of small heart structures are known to be problematic in PET imaging. Due to absence of commercial application at the beginning of the study, new dual gating method for cardiac PET imaging was developed and programmed that takes into account both contraction and respiratory induced cardiac motions. Cardiac phantom PET studies showed that small, active and moving plaques can be distinguished from myocardium activity and the gating methods improved the detection sensitivity and resolution of the plaques. In minipig and CAD patient cardiac PET studies small structures of myocardium and coronary arteries was detected more sensitive and accurately when using dual gating method than manufacturer gating methods. In cardiac patient PET study respiratory induced cardiac motions were shown to be linearly dependent with spirometry-measured respiratory volumes. Standard 3-lead electrocardiogram (ECG) measurement can be filtered by anesthesia monitor to detect lung impedance signal. In cardiac patient PET study this lung impedance signal were applied for respiratory gating. In this study was observed that the 3-lead ECG derived impedance signal gating method detects respiratory induced cardiac motion in PET as well as other externally used respiratory gating methods. In summary, the dual gated cardiac PET method is more sensitive and accurate to detect small cardiac structures, as coronary vessel wall pathology, than the commercial methods used in the study.Sydämen kaksoisliiketahdistettu PET/CT kuvantaminen Ateroskleroottisten valtimomuutosten, plakkien, seurauksena asteittain kehittyvä sepelvaltimotauti voi olla vuosia oireeton. Oireeton sepelvaltimotauti voi aiheuttaa äkkikuolemaan johtavan sydäninfarktin, mikäli sepelvaltimon seinämäplakin repeytymisestä aiheutuu verisuonen tukkiva hyytymä. Tutkimuksissa on osoitettu, että plakin tulehduksella on merkittävä rooli repeytymisalttiudelle. Repeytymisen luotettava ennakointi on yksittäisen potilaan kohdalla edelleen kliinisesti mahdotonta. Tulehtuneiden ja repeytymisalttiiden sepelvaltimoplakkien toteaminen ennen kliinisiä oireita on edelleen merkittävä tieteellinen haaste, missä positroniemissiotomografia (PET) kuvantamisella voi olla merkittävä rooli. Väitöskirjan tavoitteena oli selvittää, voidaanko kliinisessä käytössä olevalla positroniemissiotomografia ja tietokonetomografia (PET/TT) yhdistelmäkameralla havaita pieniä, sepelvaltimoplakkien kokoisia, sydämen rakenteita koneellisesti toimivissa todenmukaisissa sydänmalleissa, eläinmallissa ja sepelvaltimotautia sairastavilla potilailla. Sydämen pienten rakenteiden tarkka havaitseminen PET/TTkameroilla on haasteellista sydämen liikkumisen vuoksi. Tutkimuksessa kehitettiin ja ohjelmoitiin uusi sydämen PET-kuvantamisen liiketahdistusmenetelmä, joka ottaa huomioon sekä sydämen supistusliikkeen että hengitysliikkeen vaikutuksen sydämen PET kuvantamissa. Koneellisilla sydänmalleilla osoitettiin, että PET on riittävän herkkä havaitsemaan pieniä ja liikkuvia radioaktiivisia ”sepelvaltimoplakkeja”, ja että liiketahdistusmenetelmät parantavat plakkien havaitsemisherkkyyttä ja tarkkuutta. Eläinmallissa ja sepelvaltimotautipotilailla kaksoisliiketahdistusmenetelmän herkkyys ja tarkkuus havaita pieniä sydänlihaksen ja sepelvaltimoiden rakenteita todettiin kaupallisia tahdistusmenetelmiä paremmaksi. Potilastutkimuksissa todettiin hengityksen aiheuttama sydämen liike PET-kuvissa lineaarisesti riippuvaiseksi spirometrialla mitattujen hengitystilavuuksien kanssa. Tavallisesta 3-johtoisesta sydänsähkökäyrästä voidaan anestesiamonitorin avulla suodattaa keuhkojen impedanssisignaalia. Hengitysliikkeen aiheuttama potilaiden sydämen liike PETkuvissa havaittiin yhtä hyvin käyttämällä tätä keuhkojen impedanssisignaalia kuin muita yleisesti käytettäviä ulkoisia hengitystahdistussignaaleja. Todetaan, että kaksoisliiketahdistettu sydämen PET-kuvantamismenetelmä on tutkimuksessa käytettyjä kaupallisia menetelmiä herkempi ja tarkempi havaitsemaan sydämen pieniä rakenteita sekä sepelvaltimon seinämän tulehdusplakkeja

    Synthesis of Realistic Simultaneous Positron Emission Tomography and Magnetic Resonance Imaging Data

    Get PDF
    The investigation of the performance of different positron emission tomography (PET) reconstruction and motion compensation methods requires accurate and realistic representation of the anatomy and motion trajectories as observed in real subjects during acquisitions. The generation of well-controlled clinical datasets is difficult due to the many different clinical protocols, scanner specifications, patient sizes, and physiological variations. Alternatively, computational phantoms can be used to generate large data sets for different disease states, providing a ground truth. Several studies use registration of dynamic images to derive voxel deformations to create moving computational phantoms. These phantoms together with simulation software generate raw data. This paper proposes a method for the synthesis of dynamic PET data using a fast analytic method. This is achieved by incorporating realistic models of respiratory motion into a numerical phantom to generate datasets with continuous and variable motion with magnetic resonance imaging (MRI)-derived motion modeling and high resolution MRI images. In this paper, data sets for two different clinical traces are presented, ¹⁸F-FDG and ⁶⁸Ga-PSMA. This approach incorporates realistic models of respiratory motion to generate temporally and spatially correlated MRI and PET data sets, as those expected to be obtained from simultaneous PET-MRI acquisitions

    Motion estimation and correction for simultaneous PET/MR using SIRF and CIL

    Get PDF
    SIRF is a powerful PET/MR image reconstruction research tool for processing data and developing new algorithms. In this research, new developments to SIRF are presented, with focus on motion estimation and correction. SIRF's recent inclusion of the adjoint of the resampling operator allows gradient propagation through resampling, enabling the MCIR technique. Another enhancement enabled registering and resampling of complex images, suitable for MRI. Furthermore, SIRF's integration with the optimization library CIL enables the use of novel algorithms. Finally, SPM is now supported, in addition to NiftyReg, for registration. Results of MR and PET MCIR reconstructions are presented, using FISTA and PDHG, respectively. These demonstrate the advantages of incorporating motion correction and variational and structural priors. This article is part of the theme issue 'Synergistic tomographic image reconstruction: part 2'

    Aortic valve imaging using 18F-sodium fluoride: impact of triple motion correction

    Get PDF
    BACKGROUND: Current (18)F-NaF assessments of aortic valve microcalcification using (18)F-NaF PET/CT are based on evaluations of end-diastolic or cardiac motion-corrected (ECG-MC) images, which are affected by both patient and respiratory motion. We aimed to test the impact of employing a triple motion correction technique (3 × MC), including cardiorespiratory and gross patient motion, on quantitative and qualitative measurements. MATERIALS AND METHODS: Fourteen patients with aortic stenosis underwent two repeat 30-min PET aortic valve scans within (29 ± 24) days. We considered three different image reconstruction protocols; an end-diastolic reconstruction protocol (standard) utilizing 25% of the acquired data, an ECG-gated (four ECG gates) reconstruction (ECG-MC), and a triple motion-corrected (3 × MC) dataset which corrects for both cardiorespiratory and patient motion. All datasets were compared to aortic valve calcification scores (AVCS), using the Agatston method, obtained from CT scans using correlation plots. We report SUV(max) values measured in the aortic valve and maximum target-to-background ratios (TBR(max)) values after correcting for blood pool activity. RESULTS: Compared to standard and ECG-MC reconstructions, increases in both SUV(max) and TBR(max) were observed following 3 × MC (SUV(max): Standard = 2.8 ± 0.7, ECG-MC = 2.6 ± 0.6, and 3 × MC = 3.3 ± 0.9; TBR(max): Standard = 2.7 ± 0.7, ECG-MC = 2.5 ± 0.6, and 3 × MC = 3.3 ± 1.2, all p values ≤ 0.05). 3 × MC had improved correlations (R(2) value) to the AVCS when compared to the standard methods (SUV(max): Standard = 0.10, ECG-MC = 0.10, and 3 × MC = 0.20; TBR(max): Standard = 0.20, ECG-MC = 0.28, and 3 × MC = 0.46). CONCLUSION: 3 × MC improves the correlation between the AVCS and SUV(max) and TBR(max) and should be considered in PET studies of aortic valves using (18)F-NaF. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s40658-022-00433-7

    Motion estimation and correction for simultaneous PET/MR using SIRF and CIL

    Get PDF
    SIRF is a powerful PET/MR image reconstruction research tool for processing data and developing new algorithms. In this research, new developments to SIRF are presented, with focus on motion estimation and correction. SIRF's recent inclusion of the adjoint of the resampling operator allows gradient propagation through resampling, enabling the MCIR technique. Another enhancement enabled registering and resampling of complex images, suitable for MRI. Furthermore, SIRF's integration with the optimization library CIL enables the use of novel algorithms. Finally, SPM is now supported, in addition to NiftyReg, for registration. Results of MR and PET MCIR reconstructions are presented, using FISTA and PDHG, respectively. These demonstrate the advantages of incorporating motion correction and variational and structural priors. This article is part of the theme issue 'Synergistic tomographic image reconstruction: part 2'
    corecore