682 research outputs found

    The LOST Algorithm: finding lines and separating speech mixtures

    Get PDF
    Robust clustering of data into linear subspaces is a frequently encountered problem. Here, we treat clustering of one-dimensional subspaces that cross the origin. This problem arises in blind source separation, where the subspaces correspond directly to columns of a mixing matrix. We propose the LOST algorithm, which identifies such subspaces using a procedure similar in spirit to EM. This line finding procedure combined with a transformation into a sparse domain and an L1-norm minimisation constitutes a blind source separation algorithm for the separation of instantaneous mixtures with an arbitrary number of mixtures and sources. We perform an extensive investigation on the general separation performance of the LOST algorithm using randomly generated mixtures, and empirically estimate the performance of the algorithm in the presence of noise. Furthermore, we implement a simple scheme whereby the number of sources present in the mixtures can be detected automaticall

    Hyperspectral Unmixing Overview: Geometrical, Statistical, and Sparse Regression-Based Approaches

    Get PDF
    Imaging spectrometers measure electromagnetic energy scattered in their instantaneous field view in hundreds or thousands of spectral channels with higher spectral resolution than multispectral cameras. Imaging spectrometers are therefore often referred to as hyperspectral cameras (HSCs). Higher spectral resolution enables material identification via spectroscopic analysis, which facilitates countless applications that require identifying materials in scenarios unsuitable for classical spectroscopic analysis. Due to low spatial resolution of HSCs, microscopic material mixing, and multiple scattering, spectra measured by HSCs are mixtures of spectra of materials in a scene. Thus, accurate estimation requires unmixing. Pixels are assumed to be mixtures of a few materials, called endmembers. Unmixing involves estimating all or some of: the number of endmembers, their spectral signatures, and their abundances at each pixel. Unmixing is a challenging, ill-posed inverse problem because of model inaccuracies, observation noise, environmental conditions, endmember variability, and data set size. Researchers have devised and investigated many models searching for robust, stable, tractable, and accurate unmixing algorithms. This paper presents an overview of unmixing methods from the time of Keshava and Mustard's unmixing tutorial [1] to the present. Mixing models are first discussed. Signal-subspace, geometrical, statistical, sparsity-based, and spatial-contextual unmixing algorithms are described. Mathematical problems and potential solutions are described. Algorithm characteristics are illustrated experimentally.Comment: This work has been accepted for publication in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensin

    Single-channel source separation using non-negative matrix factorization

    Get PDF

    A review of blind source separation in NMR spectroscopy

    No full text
    27 pagesInternational audienceFourier transform is the data processing naturally associated to most NMR experiments. Notable exceptions are Pulse Field Gradient and relaxation analysis, the structure of which is only partially suitable for FT. With the revamp of NMR of complex mixtures, fueled by analytical challenges such as metabolomics, alternative and more apt mathematical methods for data processing have been sought, with the aim of decomposing the NMR signal into simpler bits. Blind source separation is a very broad definition regrouping several classes of mathematical methods for complex signal decomposition that use no hypothesis on the form of the data. Developed outside NMR, these algorithms have been increasingly tested on spectra of mixtures. In this review, we shall provide an historical overview of the application of blind source separation methodologies to NMR, including methods specifically designed for the specificity of this spectroscopy

    Nonlinear mixture-wise expansion approach to underdetermined blind separation of nonnegative dependent sources

    Get PDF
    Underdetermined blind separation of nonnegative dependent sources consists in decomposing set of observed mixed signals into greater number of original nonnegative and dependent component (source) signals. That is an important problem for which very few algorithms exist. It is also practically relevant for contemporary metabolic profiling of biological samples, such as biomarker identification studies, where sources (a.k.a. pure components or analytes) are aimed to be extracted from mass spectra of complex multicomponent mixtures. This paper presents method for underdetermined blind separation of nonnegative dependent sources. The method performs nonlinear mixture-wise mapping of observed data in high-dimensional reproducible kernel Hilbert space (RKHS) of functions and sparseness constrained nonnegative matrix factorization (NMF) therein. Thus, original problem is converted into new one with increased number of mixtures, increased number of dependent sources and higher-order (error) terms generated by nonlinear mapping. Provided that amplitudes of original components are sparsely distributed, that is the case for mass spectra of analytes, sparseness constrained NMF in RKHS yields, with significant probability, improved accuracy relative to the case when the same NMF algorithm is performed on original problem. The method is exemplified on numerical and experimental examples related respectively to extraction of ten dependent components from five mixtures and to extraction of ten dependent analytes from mass spectra of two to five mixtures. Thereby, analytes mimic complexity of components expected to be found in biological samples
    corecore