3,752 research outputs found

    Implementation of a mobile 0.15-T intraoperative MR system in pediatric neuro-oncological surgery: feasibility and correlation with early postoperative high-field strength MRI

    Get PDF
    INTRODUCTION: We analyze our preliminary experience using the PoleStar N20 mobile intraoperative MR (iMR) system as an adjunct for pediatric brain tumor resection. METHODS: We analyzed 11 resections in nine children between 1 month and 17 years old. After resection, we acquired iMR scans to detect residual tumor and update neuronavigation. We compared final iMR interpretation by the neurosurgeon with early postoperative MR interpretation by a neuroradiologist. RESULTS: Patient positioning was straightforward, and image quality (T1 7-min 4-mm sequences) sufficient in all cases. In five cases, contrast enhancement suspect for residual tumor was noted on initial postresection iMR images. In one case, a slight discrepancy with postoperative imaging after 3 months was no longer visible after 1 year. No serious perioperative adverse events related to the PoleStar N20 were encountered, except for transient shoulder pain in two. CONCLUSIONS: Using the PoleStar N20 iMR system is technically feasible and safe for both supra- and infratentorial tumor resections in children of all ages. Their small head and shoulders favor positioning in the magnet bore and allow the field of view to cover more than the area of primary interest, e.g., the ventricles in an infratentorial case. Standard surgical equipment may be used without significant limitations. In this series, the use of iMR leads to an increased extent of tumor resection in 45 % of cases. Correlation between iMR and early postoperative MR is excellent, provided image quality is optimal and interpretation is carefully done by someone sufficiently familiar with the system

    Transcranial Magnetic Resonance Imaging-Guided Focused Ultrasound Treatment at 1.5 T: A Retrospective Study on Treatment- and Patient-Related Parameters Obtained From 52 Procedures

    Get PDF
    Objective: To present a retrospective analysis of patient- and sonication-related parameters of a group of patients treated with a transcranial magnetic resonance imaging (MRI)-guided focused ultrasound (tcMRgFUS) system integrated with a 1.5-T MRI unit. Methods: The data obtained from 59 patients, who underwent the tcMRgFUS procedure from January 2015 to April 2019, were retrospectively reviewed for this study. The following data, among others, were mainly collected: skull density ratio (SDR), skull area (SA), number of available transducer elements (Tx), and estimated focal power at target (FP). For each of the four different treatment stages, we calculated the number of sonication processes (S-n), user-defined sonication power (S-p), effective measured power (S-mp), sonication duration (S-d), user-defined energy (E), effective measured energy (E-m), maximum temperature (T-max), and MR thermometry plane orientation. Furthermore, the time delay between each sonication (S-t) and the total treatment time (T-t) were recorded. Results: Fifty-two patients (40 males and 12 females; age 64.51 +/- SD 11.90 years; range 26-86 years), who underwent unilateral Vim thalamotomy (left = 50, 96.15%; right = 2, 3.85%) for medication-refractory essential tremor (n = 39; 78%) or Parkinson tremor (n = 13; 22%) were considered. A total of 1,068 (95.10%) sonication processes were included in our final analysis (average S-n per treatment: 20.65 +/- 6.18; range 13-41). The energy released onto the planned target was found to decrease with the SDR for all temperature ranges. A positive correlation was observed between the slope of T-max vs. E-m plot and the SDR (R-2 = 0.765; p < 0.001). In addition, the T-max was positively correlated with SDR (R-2 = 0.398; p < 0.005). On the contrary, no significant correlation was found between SDR and SA or Tx. An analysis of the MR thermometry scanning plane indicated that, at our site, the axial and the coronal planes were used (on average) 10.4 (SD +/- 3.8) and 7.7 (SD +/- 3.0) times, respectively, whereas the sagittal plane was used only 2.5 (SD +/- 3.0) times per treatment. Conclusion: Our results confirm the factors that significantly influence the course of a tcMRgFUS procedure even when a 1.5-T MRI scanner is used for procedure guidance. The experience we gained in this study indicates that the SDR remains one of the most significant technical parameters to be considered in a tcMRgFUS procedure. The possibility of prospectively setting the sonication energy according to the presented curves of energy delivery as a function of SDR for each treatment stage could provide a further understanding and a greater awareness of this emerging technology

    Surgical management of Glioma Grade 4: technical update from the neuro-oncology section of the Italian Society of Neurosurgery (SINch®): a systematic review

    Get PDF
    Purpose: The extent of resection (EOR) is an independent prognostic factor for overall survival (OS) in adult patients with Glioma Grade 4 (GG4). The aim of the neuro-oncology section of the Italian Society of Neurosurgery (SINch®) was to provide a general overview of the current trends and technical tools to reach this goal. Methods: A systematic review was performed. The results were divided and ordered, by an expert team of surgeons, to assess the Class of Evidence (CE) and Strength of Recommendation (SR) of perioperative drugs management, imaging, surgery, intraoperative imaging, estimation&nbsp;of EOR, surgery at tumor progression and surgery in elderly patients. Results: A total of 352 studies were identified, including 299 retrospective studies and 53 reviews/meta-analysis. The use of Dexamethasone and the avoidance of prophylaxis with anti-seizure medications reached a CE I and SR A. A preoperative imaging standard protocol was defined with CE II and SR B and usefulness of an early postoperative MRI, with CE II and SR B. The EOR was defined the strongest independent risk factor for both OS and tumor recurrence with CE II and SR B. For intraoperative imaging only the use of 5-ALA reached a CE II and SR B. The estimation of EOR was established to be fundamental in planning postoperative adjuvant treatments with CE II and SR B and the stereotactic image-guided brain biopsy to be the procedure of choice when an extensive surgical resection is not feasible (CE II and SR B). Conclusions: A growing number of evidences evidence support the role of maximal safe resection as primary OS predictor in GG4 patients. The ongoing development of intraoperative techniques for a precise real-time identification of peritumoral functional pathways enables surgeons to maximize EOR minimizing the post-operative morbidity

    Intraoperative Fluorescence Imaging for Personalized Brain Tumor Resection: Current State and Future Directions

    Get PDF
    abstract: Introduction: Fluorescence-guided surgery is one of the rapidly emerging methods of surgical “theranostics.” In this review, we summarize current fluorescence techniques used in neurosurgical practice for brain tumor patients as well as future applications of recent laboratory and translational studies. Methods: Review of the literature. Results: A wide spectrum of fluorophores that have been tested for brain surgery is reviewed. Beginning with a fluorescein sodium application in 1948 by Moore, fluorescence-guided brain tumor surgery is either routinely applied in some centers or is under active study in clinical trials. Besides the trinity of commonly used drugs (fluorescein sodium, 5-aminolevulinic acid, and indocyanine green), less studied fluorescent stains, such as tetracyclines, cancer-selective alkylphosphocholine analogs, cresyl violet, acridine orange, and acriflavine, can be used for rapid tumor detection and pathological tissue examination. Other emerging agents, such as activity-based probes and targeted molecular probes that can provide biomolecular specificity for surgical visualization and treatment, are reviewed. Furthermore, we review available engineering and optical solutions for fluorescent surgical visualization. Instruments for fluorescent-guided surgery are divided into wide-field imaging systems and hand-held probes. Recent advancements in quantitative fluorescence-guided surgery are discussed. Conclusion: We are standing on the threshold of the era of marker-assisted tumor management. Innovations in the fields of surgical optics, computer image analysis, and molecular bioengineering are advancing fluorescence-guided tumor resection paradigms, leading to cell-level approaches to visualization and resection of brain tumors.View the article as published at http://journal.frontiersin.org/article/10.3389/fsurg.2016.00055/ful

    Full Issue: Volume 13, Issue 1 - Winter 2018

    Get PDF
    Full Issue: Volume 13, Issue 1 - Winter 201

    Methods for interventional magnetic resonance imaging

    Get PDF
    This thesis has as its central aim to demonstrate, develop, discuss and promote new methods and technology for improving interventional low field magnetic resonance imaging. The work addresses problems related to accurate localization of minimally invasive surgical tools by describing novel devices and improvements to prior art techniques, such as optical tracking. In addition to instrument guidance, ablative treatment of liver tumours is discussed in connection with low field temperature measurement and the work describes suitable sequences for qualitative temperature imaging. For instrument localization, a method utilising ex vivo Overhauser enhancement of a catheter like structure was demonstrated. An enhancement factor of 10 was achieved, proving that a substantial signal gain is possible through the use of ex vivo-enhanced liquid. Similarly, a method for biopsy needle tip tracking was developed; where the position of the tip was tracked with a signal from a miniaturized electron spin resonance sample and gradient pulses. At an update rate of 10 samples per second, the accuracy was measured to be better than ±2 mm within a homogeneous sphere of 300 mm. Optical tracking methods concentrated on new indications of use for the developed optical tracking system and associated software: The system was applied to guide the needle 35 times into first sacral root foramina, with a success rate of 97%. It was also used in five bone biopsies, all of which were performed successfully, the samples allowed for a pathologic diagnosis, and the percutaneous procedures could be performed in less than 40 minutes. A new patient tracker device was developed for staged neurosurgical procedures and demonstrated with two patient cases. In the temperature measurement study, spin echo, gradient echo and completely balanced steady-state free precession sequences were optimized for maximal temperature sensitivity and the optimized sequences compared. The steady-state sequence seemed the most promising for the prediction of ablated volume in liver.reviewe

    Neuronavigation and intraoperative imaging system in orbital tumor surgery: a review of recent literature

    Get PDF
    Orbit is a small complex anatomic space that contains important structures, ocular globe, extrinsic muscles, cranial nerves, blood vessels, fat, lacrimal gland. In presence of orbital tumors it is mandatory to use a surgical approach that allows to achieve an adequate surgical field while preserving neurological function. Neuronavigation is the set of computer-assisted technologies used to guide or "navigate” the edges of the tumor to allow the surgeon during resection or biopsy. This technology started with use of CT data to get some landmarks of human anatomy defined “targets” that could be readily used in surgery. Finally, the evolution of modern neuroimaging technologies such intraoperative CT and MRI boosted the surgery accuracy. In order to identify advantages and practical use of these technologies we performed a nonsystematic review of the current literature using the keywords “orbital tumor or orbital neoplasia or orbital mass or orbital lesion” and “neuronavigation or navigation” published in last 10 years. We evaluated 29 papers and we can conclude that navigation in orbital surgery helps to reduce surgical damage while at the same time, allowing a more radical tumor resection. CT and MRI scans are complementary in diagnosing and in intraoperative navigation allow the surgeon to avoid and preserve vital structures, particularly in a complex surgical procedure without real anatomical landmarks for intraoperative orientation. Future is going towards rapid changes and the integration with intraoperative procedures is carrying on to new technologies further our contemporary bounds

    Frameless stereotactic biopsy for precision neurosurgery : diagnostic value, safety, and accuracy

    Get PDF
    BACKGROUND: Stereotactic biopsy is consistently employed to characterize cerebral lesions in patients who are not suitable for microsurgical resection. In the past years, technical improvement and neuroimaging advancements contributed to increase the diagnostic yield, the safety, and the application of this procedure. Currently, in addition to histological diagnosis, the molecular analysis is considered essential in the diagnostic process to properly select therapeutic and prognostic algorithms in a personalized approach. The present study reports our experience with frameless stereotactic brain biopsy in this molecular era. METHODS: One hundred forty consecutive patients treated from January 2013 to September 2018 were analyzed. Biopsies were performed using the Brainlab Varioguide\uae frameless stereotactic system. Patients' clinical and demographic data, the time of occupation of the operating room, the surgical time, the morbidity, and the diagnostic yield in providing a histological and molecular diagnosis were recorded and evaluated. RESULTS: The overall diagnostic yield was 93.6% with nine procedures resulting non-diagnostic. Among 110 patients with glioma, the IDH-1 mutational status was characterized in 108 cases (98.2%), resulting wild-type in all subjects but 3; MGMT methylation was characterized in 96 cases (87.3%), resulting present in 60 patients, and 1p/19q codeletion was founded in 6 of the 20 cases of grade II-III gliomas analyzed. All the specimens were apt for molecular analysis when performed. Bleeding requiring surgical drainage occurred in 2.1% of the cases; 8 (5.7%) asymptomatic hemorrhages requiring no treatment were observed. No biopsy-related mortality was recorded. Median length of hospital stay was 5 days (IQR 4-8) with mean surgical time of 60.77 min (\ub1\u200923.12) and 137.44\u2009\ub1\u200924.1 min of total occupation time of the operative room. CONCLUSIONS: Stereotactic frameless biopsy is a safe, feasible, and fast procedure to obtain a histological and molecular diagnosis
    • …
    corecore