    Power Management Techniques for Data Centers: A Survey

    Full text link
    With growing use of internet and exponential growth in amount of data to be stored and processed (known as 'big data'), the size of data centers has greatly increased. This, however, has resulted in significant increase in the power consumption of the data centers. For this reason, managing power consumption of data centers has become essential. In this paper, we highlight the need of achieving energy efficiency in data centers and survey several recent architectural techniques designed for power management of data centers. We also present a classification of these techniques based on their characteristics. This paper aims to provide insights into the techniques for improving energy efficiency of data centers and encourage the designers to invent novel solutions for managing the large power dissipation of data centers.Comment: Keywords: Data Centers, Power Management, Low-power Design, Energy Efficiency, Green Computing, DVFS, Server Consolidatio

    Energy-efficient and thermal-aware resource management for heterogeneous datacenters

    Get PDF
    International audienceWe propose in this paper to study the energy-, thermal- and performance-aware resource management in heterogeneous datacenters. Witnessing the continuous development of heterogeneity in datacenters, we are confronted with their different behaviors in terms of performance, power consumption and thermal dissipation: indeed, heterogeneity at server level lies both in the computing infrastructure (computing power, electrical power consumption) and in the heat removal systems (different enclosure, fans, thermal sinks). Also the physical locations of the servers become important with heterogeneity since some servers can (over)heat others. While many studies address independently these parameters (most of the time performance and power or energy), we show in this paper the necessity to tackle all these aspects for an optimal resource management of the computing resources. This leads to improved energy usage in a heterogeneous datacenter including the cooling of the computer rooms. We build our approach on the concept of heat distribution matrix to handle the mutual influence of the servers, in heterogeneous environments, which is novel in this context. We propose a heuristic to solve the server placement problem and we design a generic greedy framework for the online scheduling problem. We derive several single-objective heuristics (for performance, energy, cooling) and a novel fuzzy-based priority mechanism to handle their tradeoffs. Finally, we show results using extensive simulations fed with actual measurements on heterogeneous servers

    A Case Study of Edge Computing Implementations: Multi-access Edge Computing, Fog Computing and Cloudlet

    Get PDF
    With the explosive growth of intelligent and mobile devices, the current centralized cloud computing paradigm is encountering difficult challenges. Since the primary requirements have shifted towards implementing real-time response and supporting context awareness and mobility, there is an urgent need to bring resources and functions of centralized clouds to the edge of networks, which has led to the emergence of the edge computing paradigm. Edge computing increases the responsibilities of network edges by hosting computation and services, therefore enhancing performances and improving quality of experience (QoE). Fog computing, multi-access edge computing (MEC), and cloudlet are three typical and promising implementations of edge computing. Fog computing aims to build a system that enables cloud-to-thing service connectivity and works in concert with clouds, MEC is seen as a key technology of the fifth generation (5G) system, and Cloudlet is a micro-data center deployed in close proximity. In terms of deployment scenarios, Fog computing focuses on the Internet of Things (IoT), MEC mainly provides mobile RAN application solutions for 5G systems, and cloudlet offloads computing power at the network edge. In this paper, we present a comprehensive case study on these three edge computing implementations, including their architectures, differences, and their respective application scenario in IoT, 5G wireless systems, and smart edge. We discuss the requirements, benefits, and mechanisms of typical co-deployment cases for each paradigm and identify challenges and future directions in edge computing

    Adaptive runtime techniques for power and resource management on multi-core systems

    Full text link
    Energy-related costs are among the major contributors to the total cost of ownership of data centers and high-performance computing (HPC) clusters. As a result, future data centers must be energy-efficient to meet the continuously increasing computational demand. Constraining the power consumption of the servers is a widely used approach for managing energy costs and complying with power delivery limitations. In tandem, virtualization has become a common practice, as virtualization reduces hardware and power requirements by enabling consolidation of multiple applications on to a smaller set of physical resources. However, administration and management of data center resources have become more complex due to the growing number of virtualized servers installed in data centers. Therefore, designing autonomous and adaptive energy efficiency approaches is crucial to achieve sustainable and cost-efficient operation in data centers. Many modern data centers running enterprise workloads successfully implement energy efficiency approaches today. However, the nature of multi-threaded applications, which are becoming more common in all computing domains, brings additional design and management challenges. Tackling these challenges requires a deeper understanding of the interactions between the applications and the underlying hardware nodes. Although cluster-level management techniques bring significant benefits, node-level techniques provide more visibility into application characteristics, which can then be used to further improve the overall energy efficiency of the data centers. This thesis proposes adaptive runtime power and resource management techniques on multi-core systems. It demonstrates that taking the multi-threaded workload characteristics into account during management significantly improves the energy efficiency of the server nodes, which are the basic building blocks of data centers. The key distinguishing features of this work are as follows: We implement the proposed runtime techniques on state-of-the-art commodity multi-core servers and show that their energy efficiency can be significantly improved by (1) taking multi-threaded application specific characteristics into account while making resource allocation decisions, (2) accurately tracking dynamically changing power constraints by using low-overhead application-aware runtime techniques, and (3) coordinating dynamic adaptive decisions at various layers of the computing stack, specifically at system and application levels. Our results show that efficient resource distribution under power constraints yields energy savings of up to 24% compared to existing approaches, along with the ability to meet power constraints 98% of the time for a diverse set of multi-threaded applications

    Architecting Efficient Data Centers.

    Full text link
    Data center power consumption has become a key constraint in continuing to scale Internet services. As our society’s reliance on “the Cloud” continues to grow, companies require an ever-increasing amount of computational capacity to support their customers. Massive warehouse-scale data centers have emerged, requiring 30MW or more of total power capacity. Over the lifetime of a typical high-scale data center, power-related costs make up 50% of the total cost of ownership (TCO). Furthermore, the aggregate effect of data center power consumption across the country cannot be ignored. In total, data center energy usage has reached approximately 2% of aggregate consumption in the United States and continues to grow. This thesis addresses the need to increase computational efficiency to address this grow- ing problem. It proposes a new classes of power management techniques: coordinated full-system idle low-power modes to increase the energy proportionality of modern servers. First, we introduce the PowerNap server architecture, a coordinated full-system idle low- power mode which transitions in and out of an ultra-low power nap state to save power during brief idle periods. While effective for uniprocessor systems, PowerNap relies on full-system idleness and we show that such idleness disappears as the number of cores per processor continues to increase. We expose this problem in a case study of Google Web search in which we demonstrate that coordinated full-system active power modes are necessary to reach energy proportionality and that PowerNap is ineffective because of a lack of idleness. To recover full-system idleness, we introduce DreamWeaver, architectural support for deep sleep. DreamWeaver allows a server to exchange latency for full-system idleness, allowing PowerNap-enabled servers to be effective and provides a better latency- power savings tradeoff than existing approaches. Finally, this thesis investigates workloads which achieve efficiency through methodical cluster provisioning techniques. Using the popular memcached workload, this thesis provides examples of provisioning clusters for cost-efficiency given latency, throughput, and data set size targets.Ph.D.Computer Science & EngineeringUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttp://deepblue.lib.umich.edu/bitstream/2027.42/91499/1/meisner_1.pd

    Modeling and optimization of high-performance many-core systems for energy-efficient and reliable computing

    Full text link
    Thesis (Ph.D.)--Boston UniversityMany-core systems, ranging from small-scale many-core processors to large-scale high performance computing (HPC) data centers, have become the main trend in computing system design owing to their potential to deliver higher throughput per watt. However, power densities and temperatures increase following the growth in the performance capacity, and bring major challenges in energy efficiency, cooling costs, and reliability. These challenges require a joint assessment of performance, power, and temperature tradeoffs as well as the design of runtime optimization techniques that monitor and manage the interplay among them. This thesis proposes novel modeling and runtime management techniques that evaluate and optimize the performance, energy, and reliability of many-core systems. We first address the energy and thermal challenges in 3D-stacked many-core processors. 3D processors with stacked DRAM have the potential to dramatically improve performance owing to lower memory access latency and higher bandwidth. However, the performance increase may cause 3D systems to exceed the power budgets or create thermal hot spots. In order to provide an accurate analysis and enable the design of efficient management policies, this thesis introduces a simulation framework to jointly analyze performance, power, and temperature for 3D systems. We then propose a runtime optimization policy that maximizes the system performance by characterizing the application behavior and predicting the operating points that satisfy the power and thermal constraints. Our policy reduces the energy-delay product (EDP) by up to 61.9% compared to existing strategies. Performance, cooling energy, and reliability are also critical aspects in HPC data centers. In addition to causing reliability degradation, high temperatures increase the required cooling energy. Communication cost, on the other hand, has a significant impact on system performance in HPC data centers. This thesis proposes a topology-aware technique that maximizes system reliability by selecting between workload clustering and balancing. Our policy improves the system reliability by up to 123.3% compared to existing temperature balancing approaches. We also introduce a job allocation methodology to simultaneously optimize the communication cost and the cooling energy in a data center. Our policy reduces the cooling cost by 40% compared to cooling-aware and performance-aware policies, while achieving comparable performance to performance-aware policy
    • …