111 research outputs found

    Physics-Based and Data-Driven Analytics for Enhanced Planning and Operations in Power Systems with Deep Renewable Penetration

    Get PDF
    This dissertation is motivated by the lack of combined physics-based and data-driven framework for solving power system challenges that are introduced by the integration of new devices and new system components. As increasing number of stochastic generation, responsive loads, and dynamic measurements are involved in the planning and operations of modern power systems, utilities and system operators are in great need of new analysis framework that could combine physical models and measuring data together for solving challenging planning and operational problems. In view of the above challenges, the high-level objective of this dissertation is to develop a framework for integrating measurement data into large physical systems modeled by dynamical equations. To this end, the dissertation first identifies four critical tasks for the planning and operations of the modern power systems: the data collection and pre-processing, the system situational awareness, the decision making process, as well as the post-event analysis. The dissertation then takes one concrete application in each of these critical tasks as the example, and proposes the physics-based/data-driven approach for solving the challenging problems faced by this specific application. To this end, this dissertation focuses on solving the following specific problems using physics-based/data-driven approaches. First, for the data collection and pre-processing platform, a purely data-driven approach is proposed to detect bad metering data in the phasor measurement unit (PMU) monitoring systems, and ensure the overall PMU data quality. Second, for the situational awareness platform, a physics-based voltage stability assessment method is presented to improve the situational awareness of system voltage instabilities. Third, for the decision making platform, a combined physics-based and data-driven framework is proposed to support the decision making process of PMU-based power plant model validation. Forth, for the post-event analysis platform, a physics-based post-event analysis is presented to identify the root causes of the sub-synchronous oscillations induced by the wind farm integration. The above problems and proposed solutions are discussed in detail in Section 2 through Section 5. The results of this work can be integrated to address practical problems in modern power system planning and operations

    Power System Online Stability Assessment using Synchrophasor Data Mining

    Get PDF
    Traditional power system stability assessment based on full model computation shows its drawbacks in real-time applications where fast variations are present at both demand side and supply side. This work presents the use of data mining techniques, in particular the Decision Trees (DTs), for fast evaluation of power system oscillatory stability and voltage stability from synchrophasor measurements. A regression tree-based approach is proposed to predict the stability margins. Modal analysis and continuation power flow are the tools used to build the knowledge base for off-line DT training. Corresponding metrics include the damping ratio of critical electromechanical oscillation mode and MW-distance to the voltage instability region. Classification trees are used to group an operating point into predefined stability state based on the value of corresponding stability indicator. A novel methodology for knowledge base creation has been elaborated to assure practical and sufficient training data. Encouraging results are obtained through performance examination. The robustness of the proposed predictor to measurement errors and system topological variations is analyzed. A scheme has been proposed to tackle the problem of when and how to update the data mining tool for seamless online stability monitoring. The optimal placement for the phasor measurement units (PMU) based on the importance of DT variables is suggested. A measurement-based voltage stability index is proposed and evaluated using field PMU measurements. It is later revised to evaluate the impact of wind generation on distribution system voltage stability. Next, a new data mining tool, the Probabilistic Collocation Method (PCM), is presented as a computationally efficient method to conduct the uncertainty analysis. As compared with the traditional Monte Carlo simulation method, the collocation method could provide a quite accurate approximation with fewer simulation runs. Finally, we show how to overcome the disadvantages of mode meters and ringdown analyzers by using DTs to directly map synchrophasor measurements to predefined oscillatory stability states. The proposed measurement-based approach is examined using synthetic data from simulations on IEEE test systems, and PMU measurements collected from field substations. Results indicate that the proposed method complements the traditional model-based approach, enhancing situational awareness of control center operators in real time stability monitoring and control

    Cascading Outages Detection and Mitigation Tool to Prevent Major Blackouts

    Get PDF
    Due to a rise of deregulated electric market and deterioration of aged power system infrastructure, it become more difficult to deal with the grid operating contingencies. Several major blackouts in the last two decades has brought utilities to focus on development of Wide Area Monitoring, Protection and Control (WAMPAC) systems. Availability of common measurement time reference as the fundamental requirement of WAMPAC system is attained by introducing the Phasor Measurement Units, or PMUs that are taking synchronized measurements using the GPS clock signal. The PMUs can calculate time-synchronized phasor values of voltage and currents, frequency and rate of change of frequency. Such measurements, alternatively called synchrophasors, can be utilized in several applications including disturbance and islanding detection, and control schemes. In this dissertation, an integrated synchrophasor-based scheme is proposed to detect, mitigate and prevent cascading outages and severe blackouts. This integrated scheme consists of several modules. First, a fault detector based on electromechanical wave oscillations at buses equipped with PMUs is proposed. Second, a system-wide vulnerability index analysis module based on voltage and current synchrophasor measurements is proposed. Third, an islanding prediction module which utilizes an offline islanding database and an online pattern recognition neural network is proposed. Finally, as the last resort to interrupt series of cascade outages, a controlled islanding module is developed which uses spectral clustering algorithm along with power system state variable and generator coherency information

    Viiveiden vaikutus sähkömekaanisten heilahtelujen laajan alueen vaimennussäätöön

    Get PDF
    In this thesis the effects of delays on the wide-area damping control of electromechanical oscillations were studied. The research goals were two fold: to identify and define the delay sources in phasor measurement based (PMU) wide-area measurement systems for power systems, and to study the effects of delays on wide-area damping control using power system simulations as a research tool. The implementation the delays into a pre-existing power system simulation program as also a part of this work. The thesis shows and identifies the delays components and their properties in the wide-area measurement systems. It gives a survey on the reports of real delays observed in wide-area measurement systems worldwide. The simulation results show that delay has an impact on the damping control. Power system have a delay margin they are able to tolerate before turning unstable. Additionally, latency changes the properties of the electromechanical oscillations.Tässä diplomityössä tutkittiin viiveiden vaikutusta sähkömekaanisten heilahtelujen vaimennussäätöön. Työ oli karkeasti jaettavissa kahteen erilliseen osaan. Ensimmäinen osa oli voimajärjestelmien PMU-pohjaisten laajan alueen mittaus- ja ohjausjärjestelmien viivelähteiden löytäminen, tunnistaminen ja luokittelu. Toinen osa oli viiveiden vaikutusten tutkiminen laajan alueen heilahtelusäätöön käyttäen voimajärjestelmäsimulointia tutkimuksen työkaluna. Työn toteutus sisälsi viiveellistenmittauksien ja ohjauksien toteuttamisen valmiina olevaan simulaatio-ohjelmaan. Työ näyttää laajan alueen mittaus- ja ohjausjärjestelmien viivekomponentittien ominaisuudet ja vaikutuksen viiveketjuun sekä millaisia lukemia on raportoitu käytössä olevista järjestelmistä ympäri maailman. Työn viivesimulaatiot osoittavat, että viiveillä on merkitys sähkömekaanisten heilahtelujen vaimennussäätöön. Viiveellinen säätö muuttaa sähkömekaanisten heilahtelujen ominaisuuksia ja osoittaa, että voimajärjestelmillä on niille ominainen viiveen sietokyky

    Physics-Based and Data-Driven Analytics for Enhanced Planning and Operations in Power Systems with Deep Renewable Penetration

    Get PDF
    This dissertation is motivated by the lack of combined physics-based and data-driven framework for solving power system challenges that are introduced by the integration of new devices and new system components. As increasing number of stochastic generation, responsive loads, and dynamic measurements are involved in the planning and operations of modern power systems, utilities and system operators are in great need of new analysis framework that could combine physical models and measuring data together for solving challenging planning and operational problems. In view of the above challenges, the high-level objective of this dissertation is to develop a framework for integrating measurement data into large physical systems modeled by dynamical equations. To this end, the dissertation first identifies four critical tasks for the planning and operations of the modern power systems: the data collection and pre-processing, the system situational awareness, the decision making process, as well as the post-event analysis. The dissertation then takes one concrete application in each of these critical tasks as the example, and proposes the physics-based/data-driven approach for solving the challenging problems faced by this specific application. To this end, this dissertation focuses on solving the following specific problems using physics-based/data-driven approaches. First, for the data collection and pre-processing platform, a purely data-driven approach is proposed to detect bad metering data in the phasor measurement unit (PMU) monitoring systems, and ensure the overall PMU data quality. Second, for the situational awareness platform, a physics-based voltage stability assessment method is presented to improve the situational awareness of system voltage instabilities. Third, for the decision making platform, a combined physics-based and data-driven framework is proposed to support the decision making process of PMU-based power plant model validation. Forth, for the post-event analysis platform, a physics-based post-event analysis is presented to identify the root causes of the sub-synchronous oscillations induced by the wind farm integration. The above problems and proposed solutions are discussed in detail in Section 2 through Section 5. The results of this work can be integrated to address practical problems in modern power system planning and operations

    Synchronized measurement data conditioning and real-time applications

    Get PDF
    Phasor measurement units (PMU), measuring voltage and current phasor with synchronized timestamps, is the fundamental component in wide-area monitoring systems (WAMS) and reveals complex dynamic behaviors of large power systems. The synchronized measurements collected from power grid may degrade due to many factors and impacts of the distorted synchronized measurement data are significant to WAMS. This dissertation focus on developing and improving applications with distorted synchronized measurements from power grid. The contributions of this dissertation are summarized below. In Chapter 2, synchronized frequency measurements of 13 power grids over the world, including both mainland and island systems, are retrieved from Frequency Monitoring Network (FNET/GridEye) and the statistical analysis of the typical power grids are presented. The probability functions of the power grid frequency based on the measurements are calculated and categorized. Developments of generation trip/load shedding and line outage events detection and localization based on high-density PMU measurements are investigated in Chapters 3 and 4 respectively. Four different types of abnormal synchronized measurements are identified from the PMU measurements of a power grid. The impacts of the abnormal synchronized measurements on generation trip/load shedding events detection and localization are evaluated. A line outage localization method based on power flow measurements is proposed to improve the accuracy of line outage events location estimation. A deep learning model is developed to detect abnormal synchronized measurements in Chapter 5. The performance of the model is evaluated with abnormal synchronized measurements from a power grid under normal operation status. Some types of abnormal synchronized measurements in the testing cases are recently observed and reported. An extensive study of hyper-parameters in the model is conducted and evaluation metrics of the model performance are presented. A non-contact synchronized measurements study using electric field strength is investigated in Chapter 6. The theoretical foundation and equation derivations are presented. The calculation process for a single circuit AC transmission line and a double circuit AC transmission line are derived. The derived method is implemented with Matlab and tested in simulation cases

    Methodology and Tools for Field Testing of Synchrophasor Systems

    Get PDF
    The electrical power grid, as one of today’s most critical infrastructures, requires constant monitoring by operators to be aware of and react to any threats to the system’s condition. With control centers typically located far away from substations and other physical grid equipment, field measurement data forms the basis for a vast majority of control decisions in power system operation. For that reason, it is imperative to ensure the highest level of data integrity as erroneous data may lead to inappropriate control actions with potentially devastating consequences. Performance of one of the most advanced monitoring systems, the synchrophasor system, is the focus of this thesis. This research will look at testing techniques used for performance assessment of synchrophasor system performance in the field. Existing methods will be reviewed and evaluated for deficiencies in capturing system performance regarding data quality. The focus of this work will be on improving synchrophasor data quality, by introducing new testing methodology that utilizes a nested testing approach for end-to-end testing in the field using a portable test set and associated software tools. The capability of such methods and these tools to fully characterize and evaluate the performance of synchrophasor systems in the field will be validated through implementation in a large-scale testbed. The purpose of this research is to specify, develop and implement a methodology and associated tools for field-testing of synchrophasor systems. To this day, there is no dedicated standard for field-testing of synchrophasor systems. This resulted in an inability to define widely accepted procedures to detect deterioration of system performance due to poor data quality and caused communication failures, unacceptable device and subsystem accuracy, or loss of calibration. This work will demonstrate how the new approach addresses the mentioned performance assessment gap. The feasibility of implementation of the proposed test procedures will be demonstrated using different test system configurations available in a large-scale testbed. The proposed method is fully leveraging the benefits of a portable device specifically developed for field-testing, which may be used for improvement of commissioning, maintenance and troubleshooting tests for existing installations. Use Cases resulting from this work will illustrate the practical benefits of the proposed methodology and associated tools

    Synchrophasors: Multilevel Assessment and Data Quality Improvement for Enhanced System Reliability

    Get PDF
    . This study presents a comprehensive framework for testing and evaluation of Phasor Measurement Units (PMUs) and synchrophasor systems under normal power system operating conditions, as well as during disturbances such as faults and transients. The proposed framework suggests a performance assessment to be conducted in three steps: (a) type testing: conducted in the synchrophasor calibration laboratory according to accepted industrial standards; (b) application testing: conducted to evaluate the performance of the PMUs under faults, transients, and other disturbances in power systems; (c) end-to-end system testing: conducted to assess the risk and quantify the impact of measurement errors on the applications of interest. The suggested calibration toolset (type testing) enables performance characterization of different design alternatives in a standalone PMU (e.g., length of phasor estimation windows, filtering windows, reporting rates, etc.). In conjunction with the standard performance requirements, this work defines new metrics for PMU performance evaluations under any static and dynamic conditions that may unfold in the grid. The new metrics offer a more realistic understanding of the overall PMU performance and help users choose the appropriate device/settings for the target applications. Furthermore, the proposed probabilistic techniques quantify the PMU accuracy to various test performance thresholds specified by corresponding IEEE standards, rather than having only the pass/fail test outcome, as well as the probability of specific failures to meet the standard requirements defined in terms of the phasor, frequency, and rate of change of frequency accuracy. Application testing analysis encompasses PMU performance evaluation under faults and other prevailing conditions, and offers a realistic assessment of the PMU measurement errors in real-world field scenarios and reveals additional performance characteristics that are crucial for the overall application evaluation. End-to-end system tests quantify the impact of synchrophasor estimation errors and their propagation from the PMU towards the end-use applications and evaluate the associated risk. In this work, extensive experimental results demonstrate the advantages of the proposed framework and its applicability is verified through two synchrophasor applications, namely: Fault Location and Modal Analysis. Finally, a data-driven technique (Principal Component Pursuit) is proposed for the correction and completion of the synchrophasor data blocks, and its application and effectiveness is validated in modal analyzes

    Machine Learning Based Detection of False Data Injection Attacks in Wide Area Monitoring Systems

    Get PDF
    The Smart Grid (SG) is an upgraded, intelligent, and a more reliable version of the traditional Power Grid due to the integration of information and communication technologies. The operation of the SG requires a dense communication network to link all its components. But such a network renders it prone to cyber attacks jeopardizing the integrity and security of the communicated data between the physical electric grid and the control centers. One of the most prominent components of the SG are Wide Area Monitoring Systems (WAMS). WAMS are a modern platform for grid-wide information, communication, and coordination that play a major role in maintaining the stability of the grid against major disturbances. In this thesis, an anomaly detection framework is proposed to identify False Data Injection (FDI) attacks in WAMS using different Machine Learning (ML) and Deep Learning (DL) techniques, i.e., Deep Autoencoders (DAE), Long-Short Term Memory (LSTM), and One-Class Support Vector Machine (OC-SVM). These algorithms leverage diverse, complex, and high-volume power measurements coming from communications between different components of the grid to detect intelligent FDI attacks. The injected false data is assumed to target several major WAMS monitoring applications, such as Voltage Stability Monitoring (VSM), and Phase Angle Monitoring (PAM). The attack vector is considered to be smartly crafted based on the power system data, so that it can pass the conventional bad data detection schemes and remain stealthy. Due to the lack of realistic attack data, machine learning-based anomaly detection techniques are used to detect FDI attacks. To demonstrate the impact of attacks on the realistic WAMS traffic and to show the effectiveness of the proposed detection framework, a Hardware-In-the-Loop (HIL) co-simulation testbed is developed. The performance of the implemented techniques is compared on the testbed data using different metrics: Accuracy, F1 score, and False Positive Rate (FPR) and False Negative Rate (FNR). The IEEE 9-bus and IEEE 39-bus systems are used as benchmarks to investigate the framework scalability. The experimental results prove the effectiveness of the proposed models in detecting FDI attacks in WAMS
    corecore