1,294 research outputs found
Adaptive Nonlocal Filtering: A Fast Alternative to Anisotropic Diffusion for Image Enhancement
The goal of many early visual filtering processes is to remove noise while at the same time sharpening contrast. An historical succession of approaches to this problem, starting with the use of simple derivative and smoothing operators, and the subsequent realization of the relationship between scale-space and the isotropic dfffusion equation, has recently resulted in the development of "geometry-driven" dfffusion. Nonlinear and anisotropic diffusion methods, as well as image-driven nonlinear filtering, have provided improved performance relative to the older isotropic and linear diffusion techniques. These techniques, which either explicitly or implicitly make use of kernels whose shape and center are functions of local image structure are too computationally expensive for use in real-time vision applications. In this paper, we show that results which are largely equivalent to those obtained from geometry-driven diffusion can be achieved by a process which is conceptually separated info two very different functions. The first involves the construction of a vector~field of "offsets", defined on a subset of the original image, at which to apply a filter. The offsets are used to displace filters away from boundaries to prevent edge blurring and destruction. The second is the (straightforward) application of the filter itself. The former function is a kind generalized image skeletonization; the latter is conventional image filtering. This formulation leads to results which are qualitatively similar to contemporary nonlinear diffusion methods, but at computation times that are roughly two orders of magnitude faster; allowing applications of this technique to real-time imaging. An additional advantage of this formulation is that it allows existing filter hardware and software implementations to be applied with no modification, since the offset step reduces to an image pixel permutation, or look-up table operation, after application of the filter
Graph-based methods for simultaneous smoothing and sharpening of color images
[EN] In this work we introduce an image characterization of pixels based on local graphs that allows to distinguish different local regions around a pixel. This separation also permits us to develop a method for determining the role of each pixel in a neighborhood of any other, either for smoothing or for sharpening. Two methods for simultaneously conducting both processes are provided. Our solution overcomes the drawbacks of the classic two steps sequential smoothing and sharpening process: enhancing details while reducing noise and not losing critical information. The parameters of the methods are adjusted in two different ways: through observers visual quality optimization and with an objective optimization criterion. The results show that our methods outperform other recent state-of-the-art ones.We thank F. Russo for providing the implementation of the Fuzzy method and V. Ratmer, and Y.Y. Zeevi for providing the implementation of the FAB method. Cristina Jordan acknowledges the support of grant TEC2016-79884-C2-2-R. Samuel Morillas acknowledges the support of grant MTM2015-64373-P (MINECO/FEDER, Spain, UE).PĂ©rez-Benito, C.; Jordan-Lluch, C.; Conejero, JA.; Morillas, S. (2019). Graph-based methods for simultaneous smoothing and sharpening of color images. Journal of Computational and Applied Mathematics. 350:380-395. https://doi.org/10.1016/j.cam.2018.10.031S38039535
A Data-Driven Edge-Preserving D-bar Method for Electrical Impedance Tomography
In Electrical Impedance Tomography (EIT), the internal conductivity of a body
is recovered via current and voltage measurements taken at its surface. The
reconstruction task is a highly ill-posed nonlinear inverse problem, which is
very sensitive to noise, and requires the use of regularized solution methods,
of which D-bar is the only proven method. The resulting EIT images have low
spatial resolution due to smoothing caused by low-pass filtered regularization.
In many applications, such as medical imaging, it is known \emph{a priori} that
the target contains sharp features such as organ boundaries, as well as
approximate ranges for realistic conductivity values. In this paper, we use
this information in a new edge-preserving EIT algorithm, based on the original
D-bar method coupled with a deblurring flow stopped at a minimal data
discrepancy. The method makes heavy use of a novel data fidelity term based on
the so-called {\em CGO sinogram}. This nonlinear data step provides superior
robustness over traditional EIT data formats such as current-to-voltage
matrices or Dirichlet-to-Neumann operators, for commonly used current patterns.Comment: 24 pages, 11 figure
Improving Fiber Alignment in HARDI by Combining Contextual PDE Flow with Constrained Spherical Deconvolution
We propose two strategies to improve the quality of tractography results
computed from diffusion weighted magnetic resonance imaging (DW-MRI) data. Both
methods are based on the same PDE framework, defined in the coupled space of
positions and orientations, associated with a stochastic process describing the
enhancement of elongated structures while preserving crossing structures. In
the first method we use the enhancement PDE for contextual regularization of a
fiber orientation distribution (FOD) that is obtained on individual voxels from
high angular resolution diffusion imaging (HARDI) data via constrained
spherical deconvolution (CSD). Thereby we improve the FOD as input for
subsequent tractography. Secondly, we introduce the fiber to bundle coherence
(FBC), a measure for quantification of fiber alignment. The FBC is computed
from a tractography result using the same PDE framework and provides a
criterion for removing the spurious fibers. We validate the proposed
combination of CSD and enhancement on phantom data and on human data, acquired
with different scanning protocols. On the phantom data we find that PDE
enhancements improve both local metrics and global metrics of tractography
results, compared to CSD without enhancements. On the human data we show that
the enhancements allow for a better reconstruction of crossing fiber bundles
and they reduce the variability of the tractography output with respect to the
acquisition parameters. Finally, we show that both the enhancement of the FODs
and the use of the FBC measure on the tractography improve the stability with
respect to different stochastic realizations of probabilistic tractography.
This is shown in a clinical application: the reconstruction of the optic
radiation for epilepsy surgery planning
- …