4 research outputs found

    Assessment of Features between Multichannel Electrohysterogram for Differentiation of Labors

    Full text link
    [EN] Electrohysterogram (EHG) is a promising method for noninvasive monitoring of uterine electrical activity. The main purpose of this study was to characterize the multichannel EHG signals to distinguish between term delivery and preterm birth, as well as deliveries within and beyond 24 h. A total of 219 pregnant women were grouped in two ways: (1) term delivery (TD), threatened preterm labor (TPL) with the outcome of preterm birth (TPL_PB), and TPL with the outcome of term delivery (TPL_TD); (2) EHG recording time to delivery (TTD) 24 h. Three bipolar EHG signals were analyzed for the 30 min recording. Six EHG features between multiple channels, including multivariate sample entropy, mutual information, correlation coefficient, coherence, direct partial Granger causality, and direct transfer entropy, were extracted to characterize the coupling and information flow between channels. Significant differences were found for these six features between TPL and TD, and between TTD 24 h. No significant difference was found between TPL_PB and TPL_TD. The results indicated that EHG signals of TD were more regular and synchronized than TPL, and stronger coupling between multichannel EHG signals was exhibited as delivery approaches. In addition, EHG signals propagate downward for the majority of pregnant women regardless of different labors. In conclusion, the coupling and propagation features extracted from multichannel EHG signals could be used to differentiate term delivery and preterm birth and may predict delivery within and beyond 24 h.This research was funded by the National Key R&D Program, grant number 2019YFC0119700, and the National Natural Science Foundation of China, grant number U20A20388.Zhang, Y.; Hao, D.; Yang, L.; Zhou, X.; Ye Lin, Y.; Yang, Y. (2022). Assessment of Features between Multichannel Electrohysterogram for Differentiation of Labors. Sensors. 22(9):1-18. https://doi.org/10.3390/s2209335211822

    Electrohysterogram for ANN-Based Prediction of Imminent Labor in Women with Threatened Preterm Labor Undergoing Tocolytic Therapy

    Full text link
    [EN] Threatened preterm labor (TPL) is the most common cause of hospitalization in the second half of pregnancy and entails high costs for health systems. Currently, no reliable labor proximity prediction techniques are available for clinical use. Regular checks by uterine electrohysterogram (EHG) for predicting preterm labor have been widely studied. The aim of the present study was to assess the feasibility of predicting labor with a 7- and 14-day time horizon in TPL women, who may be under tocolytic treatment, using EHG and/or obstetric data. Based on 140 EHG recordings, artificial neural networks were used to develop prediction models. Non-linear EHG parameters were found to be more reliable than linear for differentiating labor in under and over 7/14 days. Using EHG and obstetric data, the <7- and <14-day labor prediction models achieved an AUC in the test group of 87.1 +/- 4.3% and 76.2 +/- 5.8%, respectively. These results suggest that EHG can be reliable for predicting imminent labor in TPL women, regardless of the tocolytic therapy stage. This paves the way for the development of diagnostic tools to help obstetricians make better decisions on treatments, hospital stays and admitting TPL women, and can therefore reduce costs and improve maternal and fetal wellbeing.This work was supported by the Spanish Ministry of Economy and Competitiveness, the European Regional Development Fund (MCIU/AEI/FEDER, UE RTI2018-094449-A-I00-AR) and by the Generalitat Valenciana (AICO/2019/220).Mas-Cabo, J.; Prats-Boluda, G.; Garcia-Casado, J.; Alberola Rubio, J.; Monfort-Ortiz, R.; Martinez-Saez, C.; Perales, A.... (2020). Electrohysterogram for ANN-Based Prediction of Imminent Labor in Women with Threatened Preterm Labor Undergoing Tocolytic Therapy. Sensors. 20(9):1-16. https://doi.org/10.3390/s20092681S116209Beck, S., Wojdyla, D., Say, L., Pilar Bertran, A., Meraldi, M., Harris Requejo, J., … Van Look, P. (2010). The worldwide incidence of preterm birth: a systematic review of maternal mortality and morbidity. Bulletin of the World Health Organization, 88(1), 31-38. doi:10.2471/blt.08.062554Zeitlin, J., Szamotulska, K., Drewniak, N., Mohangoo, A., Chalmers, J., … Sakkeus, L. (2013). Preterm birth time trends in Europe: a study of 19 countries. BJOG: An International Journal of Obstetrics & Gynaecology, 120(11), 1356-1365. doi:10.1111/1471-0528.12281Goldenberg, R. L., Culhane, J. F., Iams, J. D., & Romero, R. (2008). Epidemiology and causes of preterm birth. The Lancet, 371(9606), 75-84. doi:10.1016/s0140-6736(08)60074-4Petrou, S. (2005). The economic consequences of preterm birth duringthe first 10 years of life. BJOG: An International Journal of Obstetrics & Gynaecology, 112, 10-15. doi:10.1111/j.1471-0528.2005.00577.xLucovnik, M., Chambliss, L. R., & Garfield, R. E. (2013). Costs of unnecessary admissions and treatments for «threatened preterm labor». American Journal of Obstetrics and Gynecology, 209(3), 217.e1-217.e3. doi:10.1016/j.ajog.2013.06.046Haas, D., Benjamin, T., Sawyer, R., & Quinney, S. (2014). Short-term tocolytics for preterm delivery &ndash; current perspectives. International Journal of Women’s Health, 343. doi:10.2147/ijwh.s44048Euliano, T. Y., Nguyen, M. T., Darmanjian, S., McGorray, S. P., Euliano, N., Onkala, A., & Gregg, A. R. (2013). Monitoring uterine activity during labor: a comparison of 3 methods. American Journal of Obstetrics and Gynecology, 208(1), 66.e1-66.e6. doi:10.1016/j.ajog.2012.10.873Devedeux, D., Marque, C., Mansour, S., Germain, G., & Duchêne, J. (1993). Uterine electromyography: A critical review. American Journal of Obstetrics and Gynecology, 169(6), 1636-1653. doi:10.1016/0002-9378(93)90456-sChkeir, A., Fleury, M.-J., Karlsson, B., Hassan, M., & Marque, C. (2013). Patterns of electrical activity synchronization in the pregnant rat uterus. BioMedicine, 3(3), 140-144. doi:10.1016/j.biomed.2013.04.007Fele-Žorž, G., Kavšek, G., Novak-Antolič, Ž., & Jager, F. (2008). A comparison of various linear and non-linear signal processing techniques to separate uterine EMG records of term and pre-term delivery groups. Medical & Biological Engineering & Computing, 46(9), 911-922. doi:10.1007/s11517-008-0350-yHoroba, K., Jezewski, J., Matonia, A., Wrobel, J., Czabanski, R., & Jezewski, M. (2016). Early predicting a risk of preterm labour by analysis of antepartum electrohysterograhic signals. Biocybernetics and Biomedical Engineering, 36(4), 574-583. doi:10.1016/j.bbe.2016.06.004Vinken, M. P. G. C., Rabotti, C., Mischi, M., & Oei, S. G. (2009). Accuracy of Frequency-Related Parameters of the Electrohysterogram for Predicting Preterm Delivery. Obstetrical & Gynecological Survey, 64(8), 529-541. doi:10.1097/ogx.0b013e3181a8c6b1Vrhovec, J., Macek-Lebar, A., & Rudel, D. (s. f.). Evaluating Uterine Electrohysterogram with Entropy. IFMBE Proceedings, 144-147. doi:10.1007/978-3-540-73044-6_36Diab, A., Hassan, M., Marque, C., & Karlsson, B. (2014). Performance analysis of four nonlinearity analysis methods using a model with variable complexity and application to uterine EMG signals. Medical Engineering & Physics, 36(6), 761-767. doi:10.1016/j.medengphy.2014.01.009Lemancewicz, A., Borowska, M., Kuć, P., Jasińska, E., Laudański, P., Laudański, T., & Oczeretko, E. (2016). Early diagnosis of threatened premature labor by electrohysterographic recordings – The use of digital signal processing. Biocybernetics and Biomedical Engineering, 36(1), 302-307. doi:10.1016/j.bbe.2015.11.005Hassan, M., Terrien, J., Marque, C., & Karlsson, B. (2011). Comparison between approximate entropy, correntropy and time reversibility: Application to uterine electromyogram signals. Medical Engineering & Physics, 33(8), 980-986. doi:10.1016/j.medengphy.2011.03.010Fergus, P., Idowu, I., Hussain, A., & Dobbins, C. (2016). Advanced artificial neural network classification for detecting preterm births using EHG records. Neurocomputing, 188, 42-49. doi:10.1016/j.neucom.2015.01.107Acharya, U. R., Sudarshan, V. K., Rong, S. Q., Tan, Z., Lim, C. M., Koh, J. E., … Bhandary, S. V. (2017). Automated detection of premature delivery using empirical mode and wavelet packet decomposition techniques with uterine electromyogram signals. Computers in Biology and Medicine, 85, 33-42. doi:10.1016/j.compbiomed.2017.04.013Fergus, P., Cheung, P., Hussain, A., Al-Jumeily, D., Dobbins, C., & Iram, S. (2013). Prediction of Preterm Deliveries from EHG Signals Using Machine Learning. PLoS ONE, 8(10), e77154. doi:10.1371/journal.pone.0077154Ren, P., Yao, S., Li, J., Valdes-Sosa, P. A., & Kendrick, K. M. (2015). Improved Prediction of Preterm Delivery Using Empirical Mode Decomposition Analysis of Uterine Electromyography Signals. PLOS ONE, 10(7), e0132116. doi:10.1371/journal.pone.0132116Degbedzui, D. K., & Yüksel, M. E. (2020). Accurate diagnosis of term–preterm births by spectral analysis of electrohysterography signals. Computers in Biology and Medicine, 119, 103677. doi:10.1016/j.compbiomed.2020.103677Borowska, M., Brzozowska, E., Kuć, P., Oczeretko, E., Mosdorf, R., & Laudański, P. (2018). Identification of preterm birth based on RQA analysis of electrohysterograms. Computer Methods and Programs in Biomedicine, 153, 227-236. doi:10.1016/j.cmpb.2017.10.018Vinken, M. P. G. C., Rabotti, C., Mischi, M., van Laar, J. O. E. H., & Oei, S. G. (2010). Nifedipine-Induced Changes in the Electrohysterogram of Preterm Contractions: Feasibility in Clinical Practice. Obstetrics and Gynecology International, 2010, 1-8. doi:10.1155/2010/325635Mas-Cabo, J., Prats-Boluda, G., Perales, A., Garcia-Casado, J., Alberola-Rubio, J., & Ye-Lin, Y. (2018). Uterine electromyography for discrimination of labor imminence in women with threatened preterm labor under tocolytic treatment. Medical & Biological Engineering & Computing, 57(2), 401-411. doi:10.1007/s11517-018-1888-yBradley, A. P. (1997). The use of the area under the ROC curve in the evaluation of machine learning algorithms. Pattern Recognition, 30(7), 1145-1159. doi:10.1016/s0031-3203(96)00142-2Alexandersson, A., Steingrimsdottir, T., Terrien, J., Marque, C., & Karlsson, B. (2015). The Icelandic 16-electrode electrohysterogram database. Scientific Data, 2(1). doi:10.1038/sdata.2015.17Maner, W. (2003). Predicting term and preterm delivery with transabdominal uterine electromyography. Obstetrics & Gynecology, 101(6), 1254-1260. doi:10.1016/s0029-7844(03)00341-7Maner, W. L., & Garfield, R. E. (2007). Identification of Human Term and Preterm Labor using Artificial Neural Networks on Uterine Electromyography Data. Annals of Biomedical Engineering, 35(3), 465-473. doi:10.1007/s10439-006-9248-8Mas-Cabo, J., Prats-Boluda, G., Garcia-Casado, J., Alberola-Rubio, J., Perales, A., & Ye-Lin, Y. (2019). Design and Assessment of a Robust and Generalizable ANN-Based Classifier for the Prediction of Premature Birth by means of Multichannel Electrohysterographic Records. Journal of Sensors, 2019, 1-13. doi:10.1155/2019/5373810Terrien, J., Marque, C., & Karlsson, B. (2007). Spectral characterization of human EHG frequency components based on the extraction and reconstruction of the ridges in the scalogram. 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. doi:10.1109/iembs.2007.4352680Rooijakkers, M. J., Rabotti, C., Oei, S. G., Aarts, R. M., & Mischi, M. (2014). Low-complexity intrauterine pressure estimation using the Teager energy operator on electrohysterographic recordings. Physiological Measurement, 35(7), 1215-1228. doi:10.1088/0967-3334/35/7/1215Ahmed, M., Chanwimalueang, T., Thayyil, S., & Mandic, D. (2016). A Multivariate Multiscale Fuzzy Entropy Algorithm with Application to Uterine EMG Complexity Analysis. Entropy, 19(1), 2. doi:10.3390/e19010002Karmakar, C. K., Khandoker, A. H., Gubbi, J., & Palaniswami, M. (2009). Complex Correlation Measure: a novel descriptor for Poincaré plot. BioMedical Engineering OnLine, 8(1), 17. doi:10.1186/1475-925x-8-17Roy, B., & Ghatak, S. (2013). Nonlinear Methods to Assess Changes in Heart Rate Variability in Type 2 Diabetic Patients. Arquivos Brasileiros de Cardiologia. doi:10.5935/abc.20130181Chawla, N. V., Bowyer, K. W., Hall, L. O., & Kegelmeyer, W. P. (2002). SMOTE: Synthetic Minority Over-sampling Technique. Journal of Artificial Intelligence Research, 16, 321-357. doi:10.1613/jair.953Smrdel, A., & Jager, F. (2015). Separating sets of term and pre-term uterine EMG records. Physiological Measurement, 36(2), 341-355. doi:10.1088/0967-3334/36/2/341Kl. Comparison between Using Linear and Non-linear Features to Classify Uterine Electromyography Signals of Term and Preterm Deliveries. (2013). 2013 30th National Radio Science Conference (NRSC). doi:10.1109/nrsc.2013.6587953Aditya, S., & Tibarewala, D. N. (2012). Comparing ANN, LDA, QDA, KNN and SVM algorithms in classifying relaxed and stressful mental state from two-channel prefrontal EEG data. International Journal of Artificial Intelligence and Soft Computing, 3(2), 143. doi:10.1504/ijaisc.2012.049010Li, Q., Rajagopalan, C., & Clifford, G. D. (2014). A machine learning approach to multi-level ECG signal quality classification. Computer Methods and Programs in Biomedicine, 117(3), 435-447. doi:10.1016/j.cmpb.2014.09.002Li, Z., Zhang, Q., & Zhao, X. (2017). Performance analysis of K-nearest neighbor, support vector machine, and artificial neural network classifiers for driver drowsiness detection with different road geometries. International Journal of Distributed Sensor Networks, 13(9), 155014771773339. doi:10.1177/1550147717733391Murthy, H. S. N., & Meenakshi, D. M. (2015). ANN, SVM and KNN Classifiers for Prognosis of Cardiac Ischemia- A Comparison. Bonfring International Journal of Research in Communication Engineering, 5(2), 07-11. doi:10.9756/bijrce.8030Ren, J. (2012). ANN vs. SVM: Which one performs better in classification of MCCs in mammogram imaging. Knowledge-Based Systems, 26, 144-153. doi:10.1016/j.knosys.2011.07.016Zhang, G., Eddy Patuwo, B., & Y. Hu, M. (1998). Forecasting with artificial neural networks: International Journal of Forecasting, 14(1), 35-62. doi:10.1016/s0169-2070(97)00044-7Lawrence, S., & Giles, C. L. (2000). Overfitting and neural networks: conjugate gradient and backpropagation. Proceedings of the IEEE-INNS-ENNS International Joint Conference on Neural Networks. IJCNN 2000. Neural Computing: New Challenges and Perspectives for the New Millennium. doi:10.1109/ijcnn.2000.857823Diab, A., Hassan, M., Boudaoud, S., Marque, C., & Karlsson, B. (2013). Nonlinear estimation of coupling and directionality between signals: Application to uterine EMG propagation. 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). doi:10.1109/embc.2013.6610513Most, O., Langer, O., Kerner, R., Ben David, G., & Calderon, I. (2008). Can myometrial electrical activity identify patients in preterm labor? American Journal of Obstetrics and Gynecology, 199(4), 378.e1-378.e6. doi:10.1016/j.ajog.2008.08.003Mas-Cabo, J., Prats-Boluda, G., Ye-Lin, Y., Alberola-Rubio, J., Perales, A., & Garcia-Casado, J. (2019). Characterization of the effects of Atosiban on uterine electromyograms recorded in women with threatened preterm labor. Biomedical Signal Processing and Control, 52, 198-205. doi:10.1016/j.bspc.2019.04.001You, J., Kim, Y., Seok, W., Lee, S., Sim, D., Park, K. S., & Park, C. (2019). Multivariate Time–Frequency Analysis of Electrohysterogram for Classification of Term and Preterm Labor. Journal of Electrical Engineering & Technology, 14(2), 897-916. doi:10.1007/s42835-019-00118-9Schuit, E., Scheepers, H., Bloemenkamp, K., Bolte, A., Duvekot, H., … van Eyck, J. (2015). Predictive Factors for Delivery within 7 Days after Successful 48-Hour Treatment of Threatened Preterm Labor. American Journal of Perinatology Reports, 05(02), e141-e149. doi:10.1055/s-0035-1552930Liao, J. B., Buhimschi, C. S., & Norwitz, E. R. (2005). Normal Labor: Mechanism and Duration. Obstetrics and Gynecology Clinics of North America, 32(2), 145-164. doi:10.1016/j.ogc.2005.01.001Ye-Lin, Y., Garcia-Casado, J., Prats-Boluda, G., Alberola-Rubio, J., & Perales, A. (2014). Automatic Identification of Motion Artifacts in EHG Recording for Robust Analysis of Uterine Contractions. Computational and Mathematical Methods in Medicine, 2014, 1-11. doi:10.1155/2014/47078

    Uterine contractions clustering based on surface electromyography: an input for pregnancy monitoring

    Get PDF
    Tese de mestrado em Bioestatística, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, em 2018Inicialmente a investigação da contratilidade uterina recorria à utilização de dois métodos: o tocograma externo e o cateter de pressão intrauterino. Ambos os métodos apresentam limitações ao nível da avaliação do risco de parto prematuro e na monitorização da gravidez. O EHG (Electrohisterograma) é um método alternativo ao tocograma externo e ao cateter de pressão intrauterino. Este método pode ser aplicado de forma invasiva no músculo uterino, ou de forma não invasiva através de elétrodos colocados no abdómen. O EHG tem sido considerado uma ferramenta adequada para a monitorização da gravidez e do parto. O índice de massa corporal tem um impacto quase impercetível no EHG, sendo esta uma das principais características deste método. O EHG pode também ser utilizado para identificar as mulheres que vão entrar em trabalho de parto e ainda auxiliar na tomada de decisão médica quanto à utilização da terapia tocolítica (antagonista da oxitocina), evitando deste modo a ingestão de medicação desnecessária e os consequentes efeitos secundários. Na literatura existem apenas cinco casos publicados em que foi realizada uma separação dos principais eventos do sinal EHG: contrações, movimentos fetais, ondas Alvarez e ondas LDBF (Longue Durée Basse Fréquence). Em três das publicações a separação dos eventos foi feita manualmente e nos restantes casos algoritmos, como redes neuronais, foram aplicados ao EHG. As ondas Alvarez e as Braxton-Hicks são as mais reconhecidas. As ondas Alvarez foram descritas pela primeira vez nos anos cinquenta e as Braxton-Hicks foram descritas pela primeira vez em 1872 sendo detetadas através de palpação. As ondas Alvarez são ocasionalmente sentidas pela mulher. Estas ondas estão localizadas numa pequena área do tecido uterino sem propagação e podem levar a contrações com maior intensidade e, consequentemente, ao parto pré-termo. As Braxton-Hicks são contrações ineficientes registadas a partir da 20ª semana de gravidez que se tornam mais frequentes e intensas com o decorrer da gravidez. Estas contrações são menos localizadas que as ondas Alvarez e, durante o parto, propagam-se por todo o tecido uterino num curto período de tempo. As Braxton-Hicks estão associadas a uma diminuição do ritmo cardíaco fetal. As ondas LDBF são contrações de longa duração associadas a hipertonia uterina, quando há contração do tecido uterino sem retorno ao relaxamento muscular, o que representa um risco na gravidez. Neste trabalho foram utilizadas duas bases de dados. Na base de dados da Islândia existem 122 registos de 45 mulheres, dos quais apenas 4 correspondem a partos pré-termo. Na base de dados TPEHG (Term-Preterm EHG) existem 300 registos, dos quais 38 correspondem a partos pré-termo. Neste trabalho foram escolhidos canais bipolares, visto que estes reduzem o ruído idêntico, como o ECG (Eletrocardiograma) materno ou movimentos respiratórios. Para ambas as bases de dados os sinais originais de EHG foram processados e filtrados. Na estimação espetral foram considerados dois métodos: paramétricos e não paramétricos. O método Welch foi escolhido pois representa um bom compromisso entre ambos. Este método foi utilizado para calcular o espectro de cada evento detetado no sinal EHG. Para detetar os eventos no sinal EHG foram considerados cinco métodos baseados na energia ou amplitude. O método Wavelet foi o escolhido pois após uma inspeção visual, este era o método que delineava melhor as contrações. Na base de dados da Islândia foram identificadas 3136 contrações e na TPEHG foram encontradas 4622 contrações. O objetivo principal desta tese é obter clusters de contrações detetadas no sinal EHG. No entanto, as contrações são séries temporais não estacionárias, e a sua classificação visual é inviável a longo termo e também difícil de aplicar na prática clínica. Existem vários parâmetros que podem ser extraídos do sinal EHG, mas o espectro das contrações foi o método escolhido visto que este representa o sinal EHG e tem sempre a mesma dimensão, independentemente da duração da contração. As distâncias espetrais têm sido utilizadas com sucesso no reconhecimento áudio. Neste trabalho foi realizada uma aplicação desse método ao processamento do EHG, no qual foram realizados os ajustes necessários. Para comparar os espectros foram estudadas 8 distâncias diferentes: Itakura-Saito, COSH, Itakura, Itakura simétrica, Kullback-Leibler, Jeffrey, Rényi e Jensen-Rényi. Apenas as distâncias simétricas foram selecionadas para um estudo mais detalhado visto que estas são, segundo a literatura, as distâncias mais adequadas aquando do clustering. Após comparação das distâncias simétricas, a divergência de Jeffrey foi a selecionada para a comparação dos espectros. Nesta tese foram avaliados três métodos diferentes de clustering: o linkage, o K-means e o K-medoids. O linkage é um método hierárquico. Os clusters que resultam do agrupamento hierárquico estão organizados numa estrutura chamada dendrograma. No agrupamento hierárquico, não é necessário predeterminar o número de clusters, o que torna este um método ideal na exploração dos dados. O K-means e o K-medoids são métodos de partição, nos quais os dados são separados em k clusters decididos previamente. Os clusters são definidos de forma a otimizar a função da distância. No algoritmo K-means, os clusters baseiam-se na proximidade entre si de acordo com uma distância predeterminada. A diferença entre o K-medoids e o K-means é que o K-medoids escolhe pontos de dados como centros, chamados de medoides, enquanto K-means usa centróides. Após uma comparação dos diferentes métodos de clustering foi escolhido neste trabalho foi o average linkage, visto que este apresentava melhores resultados quer na separação dos espectros quer na silhueta. É então apresentado um método inovador no qual se utiliza todo o espectro das contrações detetadas automaticamente no EHG para o clustering não supervisionado. Esta técnica é uma contribuição para a classificação automática das diferentes contrações, especialmente aquelas mais reconhecidas na literatura: Alvarez e Braxton-Hicks. Era expectável encontrar um cluster isolado com as ondas LDBF, visto que estas representam um risco para o feto. O principal objetivo era juntar num cluster os espectros semelhantes das contrações, e relacioná-lo com o respetivo tipo de contração. Essa tarefa foi concluída através da identificação positiva de Alvarez e Braxton-Hicks. O clustering forneceu ainda algumas pistas sobre ondas Alvarez que não foram encontradas com o algoritmo de deteção de contrações, situação para a qual um método alternativo é apresentado. É sugerido que as ondas Alvarez sejam detetadas com métodos baseados na frequência, como, por exemplo, a frequência instantânea, no entanto este método não foi desenvolvido neste trabalho. Em relação às ondas LDBF, estas foram encontradas no cluster das Braxton-Hicks. É sugerido que a deteção das ondas LDBF seja baseada na sua caraterística mais distinta: a longa duração. Verificou-se que os casos pré-termo e os registos pré-parto não ficaram isolados num cluster, não se tendo encontrado uma relação entre a idade gestacional e o tipo de contração. Conclui-se que as contrações mais curtas apresentam maior amplitude do que as contrações com maior duração. Baseado em estudos anteriores sobre a eletrofisiologia do útero, supõem-se que o início do trabalho de parto pré-termo e termo esteja associado a sequências específicas de diferentes tipos de contrações, nas quais as ondas Alvares desempenham um papel importante. As contrações identificadas como Alvarez e Braxton-Hicks não são usadas como tal na prática clínica apesar de a maioria das contrações detetadas pelo tocograma serem Braxton-Hicks. O interesse pelas ondas Alvarez diminuiu rapidamente visto que estas ondas são praticamente indetetáveis pelo método de referência de deteção de contrações: o tocograma. As capacidades e a resolução do EHG levaram à renovação do estudo das contrações mais subtis, incluindo as Alvarez. Este trabalho é uma contribuição para a investigação nesta área.An innovative technique is introduced wherein where an unsupervised clustering method using as feature the whole spectrum of automatically detected contractions on the EHG (Electrohysterogram) is presented as a contribution to the automatic classification of the different uterine contractions, at least those that have been most recognized in the literature: Alvarez and Braxton-Hicks. It was expected to also be able to cluster the LDBF (Longue Durée Basse Fréquence) components, as these pose a fetal risk. The main task was to have the spectral contractions descriptions clustered and linked to the respective contraction type. That task was completed with positive identification of the Alvarez and Braxton-Hicks. The clustering process also provided clues regarding the missed Alvarez waves in the contraction detection algorithm, for which an alternative technique is suggested but not developed in this work. Regarding the LDBF they were found in the Braxton-Hicks cluster. It is suggested the LDBF´s to be detected based in their most prominent feature: the long duration. It is presented the rationale behind the selection of a cost function to be used in the spectral distance’s algorithm. Spectral distances have been successfully used in audio recognition and this works represents an application to the EHG processing, for which the necessary adjustments have to be implemented. It was found that no single cluster pointed to the preterm cases, or indeed to the pre-labor subject recordings. It is hypothesized, based on previous studies in uterine electrophysiology, that the initiation of pre-term or term labor should be associated with triggering contraction sequences of different types, where the Alvarez waves play a major role. Alvarez and Braxton-Hicks, labeled as such, are not typically used in the clinical environment despite most of the Tocogram detected contractions being the latter. Alvarez waves are not usually detectable by the Tocogram. Alvarez were firstly detected invasively in the early fifties, and Braxton-Hicks in 1872 using routine palpation techniques. The interest in Alvarez components declined rapidly since being practically undetectable by the de facto reference in the contraction detection: the Tocogram. The EHG capabilities and resolution made it possible to revive the research on the most subtle uterine contractions, Alvarez included and this work is a contribution in this research area
    corecore