3,290 research outputs found
Classification of Arrhythmia by Using Deep Learning with 2-D ECG Spectral Image Representation
The electrocardiogram (ECG) is one of the most extensively employed signals
used in the diagnosis and prediction of cardiovascular diseases (CVDs). The ECG
signals can capture the heart's rhythmic irregularities, commonly known as
arrhythmias. A careful study of ECG signals is crucial for precise diagnoses of
patients' acute and chronic heart conditions. In this study, we propose a
two-dimensional (2-D) convolutional neural network (CNN) model for the
classification of ECG signals into eight classes; namely, normal beat,
premature ventricular contraction beat, paced beat, right bundle branch block
beat, left bundle branch block beat, atrial premature contraction beat,
ventricular flutter wave beat, and ventricular escape beat. The one-dimensional
ECG time series signals are transformed into 2-D spectrograms through
short-time Fourier transform. The 2-D CNN model consisting of four
convolutional layers and four pooling layers is designed for extracting robust
features from the input spectrograms. Our proposed methodology is evaluated on
a publicly available MIT-BIH arrhythmia dataset. We achieved a state-of-the-art
average classification accuracy of 99.11\%, which is better than those of
recently reported results in classifying similar types of arrhythmias. The
performance is significant in other indices as well, including sensitivity and
specificity, which indicates the success of the proposed method.Comment: 14 pages, 5 figures, accepted for future publication in Remote
Sensing MDPI Journa
Detection of atrial fibrillation episodes in long-term heart rhythm signals using a support vector machine
Atrial fibrillation (AF) is a serious heart arrhythmia leading to a significant increase of the risk for occurrence of ischemic stroke. Clinically, the AF episode is recognized in an electrocardiogram. However, detection of asymptomatic AF, which requires a long-term monitoring, is more efficient when based on irregularity of beat-to-beat intervals estimated by the heart rate (HR) features. Automated classification of heartbeats into AF and non-AF by means of the Lagrangian Support Vector Machine has been proposed. The classifier input vector consisted of sixteen features, including four coefficients very sensitive to beat-to-beat heart changes, taken from the fetal heart rate analysis in perinatal medicine. Effectiveness of the proposed classifier has been verified on the MIT-BIH Atrial Fibrillation Database. Designing of the LSVM classifier using very large number of feature vectors requires extreme computational efforts. Therefore, an original approach has been proposed to determine a training set of the smallest possible size that still would guarantee a high quality of AF detection. It enables to obtain satisfactory results using only 1.39% of all heartbeats as the training data. Post-processing stage based on aggregation of classified heartbeats into AF episodes has been applied to provide more reliable information on patient risk. Results obtained during the testing phase showed the sensitivity of 98.94%, positive predictive value of 98.39%, and classification accuracy of 98.86%.Web of Science203art. no. 76
Heartbeat Anomaly Detection using Adversarial Oversampling
Cardiovascular diseases are one of the most common causes of death in the
world. Prevention, knowledge of previous cases in the family, and early
detection is the best strategy to reduce this fact. Different machine learning
approaches to automatic diagnostic are being proposed to this task. As in most
health problems, the imbalance between examples and classes is predominant in
this problem and affects the performance of the automated solution. In this
paper, we address the classification of heartbeats images in different
cardiovascular diseases. We propose a two-dimensional Convolutional Neural
Network for classification after using a InfoGAN architecture for generating
synthetic images to unbalanced classes. We call this proposal Adversarial
Oversampling and compare it with the classical oversampling methods as SMOTE,
ADASYN, and RandomOversampling. The results show that the proposed approach
improves the classifier performance for the minority classes without harming
the performance in the balanced classes
Leave-one-out prediction error of systolic arterial pressure time series under paced breathing
In this paper we show that different physiological states and pathological
conditions may be characterized in terms of predictability of time series
signals from the underlying biological system. In particular we consider
systolic arterial pressure time series from healthy subjects and Chronic Heart
Failure patients, undergoing paced respiration. We model time series by the
regularized least squares approach and quantify predictability by the
leave-one-out error. We find that the entrainment mechanism connected to paced
breath, that renders the arterial blood pressure signal more regular, thus more
predictable, is less effective in patients, and this effect correlates with the
seriousness of the heart failure. The leave-one-out error separates controls
from patients and, when all orders of nonlinearity are taken into account,
alive patients from patients for which cardiac death occurred
- …