Model validation for a noninvasive arterial stenosis detection problem
Copyright @ 2013 American Institute of Mathematical SciencesA current thrust in medical research is the development of a non-invasive method for detection, localization, and characterization of an arterial stenosis (a blockage or partial blockage in an artery). A method has been proposed to detect shear waves in the chest cavity which have been generated by disturbances in the blood flow resulting from a stenosis. In order to develop this methodology further, we use both one-dimensional pressure and shear wave experimental data from novel acoustic phantoms to validate corresponding viscoelastic mathematical models, which were developed in a concept paper [8] and refined herein. We estimate model parameters which give a good fit (in a sense to be precisely defined) to the experimental data, and use asymptotic error theory to provide confidence intervals for parameter estimates. Finally, since a robust error model is necessary for accurate parameter estimates and confidence analysis, we include a comparison of absolute and relative models for measurement error.The National Institute of Allergy and Infectious Diseases, the Air Force Office of Scientific Research, the Deopartment of Education and the Engineering and Physical Sciences Research Council (EPSRC)
Influence of wall thickness and diameter on arterial shear wave elastography: a phantom and finite element study
Quantitative, non-invasive and local measurements of arterial mechanical
properties could be highly beneficial for early diagnosis of cardiovascular
disease and follow up of treatment. Arterial shear wave elastography (SWE)
and wave velocity dispersion analysis have previously been applied to
measure arterial stiffness. Arterial wall thickness (h) and inner diameter (D)
vary with age and pathology and may influence the shear wave propagation.
Nevertheless, the effect of arterial geometry in SWE has not yet been
systematically investigated. In this study the influence of geometry on the
estimated mechanical properties of plates (h = 0.5–3 mm) and hollow
cylinders (h = 1, 2 and 3 mm, D = 6 mm) was assessed by experiments in
phantoms and by finite element method simulations. In addition, simulations
in hollow cylinders with wall thickness difficult to achieve in phantoms
were performed (h = 0.5–1.3 mm, D = 5–8 mm). The phase velocity curves obtained from experiments and simulations were compared in the frequency
range 200–1000 Hz and showed good agreement (R2 = 0.80 ± 0.07 for plates
and R2 = 0.82 ± 0.04 for hollow cylinders). Wall thickness had a larger effect
than diameter on the dispersion curves, which did not have major effects above
400 Hz. An underestimation of 0.1–0.2 mm in wall thickness introduces an
error 4–9 kPa in hollow cylinders with shear modulus of 21–26 kPa. Therefore,
wall thickness should correctly be measured in arterial SWE applications for
accurate mechanical properties estimation
Flow velocity mapping using contrast enhanced high-frame-rate plane wave ultrasound and image tracking: methods and initial in vitro and in vivo evaluation
Ultrasound imaging is the most widely used method for visualising and quantifying blood flow in medical practice, but existing techniques have various limitations in terms of imaging sensitivity, field of view, flow angle dependence, and imaging depth. In this study, we developed an ultrasound imaging velocimetry approach capable of visualising and quantifying dynamic flow, by combining high-frame-rate plane wave ultrasound imaging, microbubble contrast agents, pulse inversion contrast imaging and speckle image tracking algorithms. The system was initially evaluated in vitro on both straight and carotid-mimicking vessels with steady and pulsatile flows and in vivo in the rabbit aorta. Colour and spectral Doppler measurements were also made. Initial flow mapping results were compared with theoretical prediction and reference Doppler measurements and indicate the potential of the new system as a highly sensitive, accurate, angle-independent and full field-of-view velocity mapping tool capable of tracking and quantifying fast and dynamic flows
Artifact Rejection Methodology Enables Continuous, Noninvasive Measurement of Gastric Myoelectric Activity in Ambulatory Subjects.
The increasing prevalence of functional and motility gastrointestinal (GI) disorders is at odds with bottlenecks in their diagnosis, treatment, and follow-up. Lack of noninvasive approaches means that only specialized centers can perform objective assessment procedures. Abnormal GI muscular activity, which is coordinated by electrical slow-waves, may play a key role in symptoms. As such, the electrogastrogram (EGG), a noninvasive means to continuously monitor gastric electrical activity, can be used to inform diagnoses over broader populations. However, it is seldom used due to technical issues: inconsistent results from single-channel measurements and signal artifacts that make interpretation difficult and limit prolonged monitoring. Here, we overcome these limitations with a wearable multi-channel system and artifact removal signal processing methods. Our approach yields an increase of 0.56 in the mean correlation coefficient between EGG and the clinical "gold standard", gastric manometry, across 11 subjects (p < 0.001). We also demonstrate this system's usage for ambulatory monitoring, which reveals myoelectric dynamics in response to meals akin to gastric emptying patterns and circadian-related oscillations. Our approach is noninvasive, easy to administer, and has promise to widen the scope of populations with GI disorders for which clinicians can screen patients, diagnose disorders, and refine treatments objectively
Aerospace Medicine and Biology: A continuing bibliography, supplement 191
A bibliographical list of 182 reports, articles, and other documents introduced into the NASA scientific and technical information system in February 1979 is presented
- …