1,775 research outputs found
Experimental Evaluation of the Projection-based Force Reflection Algorithms for Haptic Interaction with Virtual Environment
Haptic interaction with virtual environments is currently a major and growing area of research with a number of emerging applications, particularly in the field of robotics. Digital implementation of the virtual environments, however, introduces errors which may result in instability of the haptic displays. This thesis deals with experimental investigation of the Projection-Based Force Reflection Algorithms (PFRAs) for haptic interaction with virtual environments, focusing on their performance in terms of stability and transparency. Experiments were performed to compare the PFRA in terms of performance for both non-delayed and delayed haptic interactions with more conventional haptic rendering methods, such as the Virtual Coupling (VC) and Wave Variables (WV). The results demonstrated that the PFRA is more stable, guarantees higher levels of transparency, and is less sensitive to decrease in update rates
Control of Cooperative Haptics-Enabled Teleoperation Systems with Application to Minimally Invasive Surgery
Robot-Assisted Minimally Invasive Surgical (RAMIS) systems frequently have a structure of cooperative teleoperator systems where multiple master-slave pairs are used to collaboratively execute a task. Although multiple studies indicate that haptic feedback improves the realism of tool-tissue interaction to the surgeon and leads to better performance for surgical procedures, current telesurgical systems typically do not provide force feedback, mainly because of the inherent stability issues. The research presented in this thesis is directed towards the development of control algorithms for force reflecting cooperative surgical teleoperator systems with improved stability and transparency characteristics. In the case of cooperative force reflecting teleoperation over networks, conventional passivity based approaches may have limited applicability due to potentially non-passive slave-slave interactions and irregular communication delays imposed by the network. In this thesis, an alternative small gain framework for the design of cooperative network-based force reflecting teleoperator systems is developed. Using the small gain framework, control algorithms for cooperative force-reflecting teleoperator systems are designed that guarantee stability in the presence of multiple network-induced communication constraints. Furthermore, the design conservatism typically associated with the small-gain approach is eliminated by using the Projection-Based Force Reflection (PBFR) algorithms. Stability results are established for networked cooperative teleoperator systems under different types of force reflection algorithms in the presence of irregular communication delays. The proposed control approach is consequently implemented on a dual-arm (two masters/two slaves) robotic MIS testbed. The testbed consists of two Haptic Wand devices as masters and two PA10-7C robots as the slave manipulators equipped with da Vinci laparoscopic surgical instruments. The performance of the proposed control approach is evaluated in three different cooperative surgical tasks, which are knot tightening, pegboard transfer, and object manipulation. The experimental results obtained indicate that the PBFR algorithms demonstrate statistically significant performance improvement in comparison with the conventional direct force reflection algorithms. One possible shortcoming of using PBFR algorithms is that implementation of these algorithms may lead to attenuation of the high-frequency component of the contact force which is important, in particular, for haptic perception of stiff surfaces. In this thesis, a solution to this problem is proposed which is based on the idea of separating the different frequency bands in the force reflection signal and consequently applying the projection-based principle to the low-frequency component, while reflecting the high-frequency component directly. The experimental results demonstrate that substantial improvement in transient fidelity of the force feedback is achieved using the proposed method without negative effects on the stability of the system
The Shape of Damping: Optimizing Damping Coefficients to Improve Transparency on Bilateral Telemanipulation
This thesis presents a novel optimization-based passivity control algorithm for hapticenabled bilateral teleoperation systems involving multiple degrees of freedom. In particular, in the context of energy-bounding control, the contribution focuses on the implementation of a passivity layer for an existing time-domain scheme, ensuring optimal transparency of the interaction along subsets of the environment space which are preponderant for the given task, while preserving the energy bounds required for passivity. The involved optimization problem is convex and amenable to real-time implementation. The effectiveness of the proposed design is validated via an experiment performed on a virtual teleoperated environment.
The interplay between transparency and stability is a critical aspect in haptic-enabled bilateral teleoperation control. While it is important to present the user with the true impedance of the environment, destabilizing factors such as time delays, stiff environments, and a relaxed grasp on the master device may compromise the stability and safety of the system. Passivity has been exploited as one of the the main tools for providing sufficient conditions for stable teleoperation in several controller design approaches, such as the scattering algorithm, timedomain passivity control, energy bounding algorithm, and passive set position modulation.
In this work it is presented an innovative energy-based approach, which builds upon existing time-domain passivity controllers, improving and extending their effectiveness and functionality.
The set of damping coefficients are prioritized in each degree of freedom, the resulting transparency presents a realistic force feedback in comparison to the other directions. Thus, the prioritization takes effect using a quadratic programming algorithm to find the optimal values for the damping.
Finally, the energy tanks approach on passivity control is a solution used to ensure stability in a system for robotics bilateral manipulation. The bilateral telemanipulation must maintain the principle of passivity in all moments to preserve the system\u2019s stability. This work presents a brief introduction to haptic devices as a master component on the telemanipulation chain; the end effector in the slave side is a representation of an interactive object within an environment having a force sensor as feedback signal. The whole interface is designed into a cross-platform framework named ROS, where the user interacts with the system. Experimental results are presented
Posture-Dependent Projection-Based Force Reflection Algorithms for Bilateral Teleoperators
It was previously established that the projection-based force reflection (PBFR) algorithms improve the overall stability of a force reflecting teleoperation system. The idea behind the PBFR algorithms is to identify the component of the reflected force which is compensated by interaction with the operator\u27s hand, and subsequently attenuate the residual component of the reflected force. If there is no a priori information regarding the behaviour of the human operator, the PBFR gain is selected equal to sufficiently small constant in order to guarantee stability for a wide range of human operator responses. Small PBRF gains, however, may deteriorate the transparency of a teleoperator system. In this thesis, a new method for selecting the PBFR gain is introduced which depends on human postures. Using an online human posture estimation, the introduced posture-dependent PBFR algorithm has been applied to a teleoperation system with force feedback. It is experimentally demonstrated that the developed method for selection of the PBFR gain based on human postures improves the transparency of the teleoperator system while the stability is preserved. Finally, preliminary results that deal with an extension of the developed methods towards a more realistic model of the human arm with 4 degrees of freedom and three dimensional movements are presented
Design and performance evaluation of a prototype MRF-based haptic interface for medical applications
This paper describes the construction and stability and transparency evaluation of a prototype two degrees-of-freedom (DoF) haptic interface, which takes ad-vantage of magneto-rheological fluid (MRF)-based clutches for actuation. These small-scale clutches were designed in our lab, and their evaluation were reported previously [1],[2]. MRF-based actuators exhibit superior characteristics,which can significantly contribute to transparency and stability of haptic devices. Based on these actuators, a distributed antagonistic configuration is used to develop the2-DoF haptic interface. This device is incorporated in a master–slave teleoperation setup intended for medical per-cutaneous interventions and soft-tissue palpation. Preliminary studies on the stability and transparency of the haptic interface in this setup using phantom and ex vivo samples show the great potential of MRF-based actuators for integr-tion in haptic devices that require reliable, safe, accurate,highly transparent, and stable force reflection
The Design of a Haptic Device for Training and Evaluating Surgeon and Novice Laparoscopic Movement Skills
As proper levels of force application are necessary to ensure patient safety, and training hours with an expert on live subjects are difficult, enhanced computer-based training is needed to teach the next generation of surgeons. Considering the role of touch in surgery, there is a need for a device capable of discerning the haptic ability of surgical trainees. This need is amplified by minimally invasive surgical techniques where a surgeon\u27s sense of tissue properties comes not directly through their own hands but indirectly through the tools. A haptic device capable of producing a realistic range of forces and motions that can be used to test the ability of users to replicate salient forces in specific maneuvers is proposed. This device also provides the opportunity to use inexpensive haptic trainers to educate surgeons about proper force application. A novel haptic device was designed and built to provide a simplified analogy of the forces and torques felt during free tool motion and constrained pushing, sweep with laparoscopic instruments. The device is realized as a single-degree-of-freedom robotic system controlled using real-time computer hardware and software. The details of the device design and the results of testing the design against the specifications are presented. A significant achievement in the design is the use of a two-camera vision system to sense the user placement of the input device. The capability of the device as a first-order screening tool to distinguish between novices and expert surgeons is described
Research on real-time physics-based deformation for haptic-enabled medical simulation
This study developed a multiple effective visuo-haptic surgical engine to handle a variety of surgical manipulations in real-time. Soft tissue models are based on biomechanical experiment and continuum mechanics for greater accuracy. Such models will increase the realism of future training systems and the VR/AR/MR implementations for the operating room
A continuum robotic platform for endoscopic non-contact laser surgery: design, control, and preclinical evaluation
The application of laser technologies in surgical interventions has been accepted in the clinical
domain due to their atraumatic properties. In addition to manual application of fibre-guided
lasers with tissue contact, non-contact transoral laser microsurgery (TLM) of laryngeal tumours
has been prevailed in ENT surgery. However, TLM requires many years of surgical training
for tumour resection in order to preserve the function of adjacent organs and thus preserve the
patient’s quality of life. The positioning of the microscopic laser applicator outside the patient
can also impede a direct line-of-sight to the target area due to anatomical variability and limit
the working space. Further clinical challenges include positioning the laser focus on the tissue
surface, imaging, planning and performing laser ablation, and motion of the target area during
surgery. This dissertation aims to address the limitations of TLM through robotic approaches and
intraoperative assistance. Although a trend towards minimally invasive surgery is apparent, no
highly integrated platform for endoscopic delivery of focused laser radiation is available to date.
Likewise, there are no known devices that incorporate scene information from endoscopic imaging
into ablation planning and execution. For focusing of the laser beam close to the target tissue, this
work first presents miniaturised focusing optics that can be integrated into endoscopic systems.
Experimental trials characterise the optical properties and the ablation performance. A robotic
platform is realised for manipulation of the focusing optics. This is based on a variable-length
continuum manipulator. The latter enables movements of the endoscopic end effector in five
degrees of freedom with a mechatronic actuation unit. The kinematic modelling and control of the
robot are integrated into a modular framework that is evaluated experimentally. The manipulation
of focused laser radiation also requires precise adjustment of the focal position on the tissue. For
this purpose, visual, haptic and visual-haptic assistance functions are presented. These support
the operator during teleoperation to set an optimal working distance. Advantages of visual-haptic
assistance are demonstrated in a user study. The system performance and usability of the overall
robotic system are assessed in an additional user study. Analogous to a clinical scenario, the
subjects follow predefined target patterns with a laser spot. The mean positioning accuracy of the
spot is 0.5 mm. Finally, methods of image-guided robot control are introduced to automate laser
ablation. Experiments confirm a positive effect of proposed automation concepts on non-contact
laser surgery.Die Anwendung von Lasertechnologien in chirurgischen Interventionen hat sich aufgrund der atraumatischen Eigenschaften in der Klinik etabliert. Neben manueller Applikation von fasergefĂĽhrten
Lasern mit Gewebekontakt hat sich die kontaktfreie transorale Lasermikrochirurgie (TLM) von
Tumoren des Larynx in der HNO-Chirurgie durchgesetzt. Die TLM erfordert zur Tumorresektion
jedoch ein langjähriges chirurgisches Training, um die Funktion der angrenzenden Organe zu
sichern und damit die Lebensqualität der Patienten zu erhalten. Die Positionierung des mikroskopis chen Laserapplikators außerhalb des Patienten kann zudem die direkte Sicht auf das Zielgebiet
durch anatomische Variabilität erschweren und den Arbeitsraum einschränken. Weitere klinische
Herausforderungen betreffen die Positionierung des Laserfokus auf der Gewebeoberfläche, die
Bildgebung, die Planung und AusfĂĽhrung der Laserablation sowie intraoperative Bewegungen
des Zielgebietes. Die vorliegende Dissertation zielt darauf ab, die Limitierungen der TLM durch
robotische Ansätze und intraoperative Assistenz zu adressieren. Obwohl ein Trend zur minimal
invasiven Chirurgie besteht, sind bislang keine hochintegrierten Plattformen fĂĽr die endoskopische
Applikation fokussierter Laserstrahlung verfĂĽgbar. Ebenfalls sind keine Systeme bekannt, die
Szeneninformationen aus der endoskopischen Bildgebung in die Ablationsplanung und -ausfĂĽhrung
einbeziehen. Für eine situsnahe Fokussierung des Laserstrahls wird in dieser Arbeit zunächst
eine miniaturisierte Fokussieroptik zur Integration in endoskopische Systeme vorgestellt. Experimentelle Versuche charakterisieren die optischen Eigenschaften und das Ablationsverhalten. Zur
Manipulation der Fokussieroptik wird eine robotische Plattform realisiert. Diese basiert auf einem
längenveränderlichen Kontinuumsmanipulator. Letzterer ermöglicht in Kombination mit einer
mechatronischen Aktuierungseinheit Bewegungen des Endoskopkopfes in fĂĽnf Freiheitsgraden.
Die kinematische Modellierung und Regelung des Systems werden in ein modulares Framework
eingebunden und evaluiert. Die Manipulation fokussierter Laserstrahlung erfordert zudem eine
präzise Anpassung der Fokuslage auf das Gewebe. Dafür werden visuelle, haptische und visuell haptische Assistenzfunktionen eingeführt. Diese unterstützen den Anwender bei Teleoperation
zur Einstellung eines optimalen Arbeitsabstandes. In einer Anwenderstudie werden Vorteile der
visuell-haptischen Assistenz nachgewiesen. Die Systemperformanz und Gebrauchstauglichkeit
des robotischen Gesamtsystems werden in einer weiteren Anwenderstudie untersucht. Analog zu
einem klinischen Einsatz verfolgen die Probanden mit einem Laserspot vorgegebene Sollpfade. Die
mittlere Positioniergenauigkeit des Spots beträgt dabei 0,5 mm. Zur Automatisierung der Ablation
werden abschließend Methoden der bildgestützten Regelung vorgestellt. Experimente bestätigen
einen positiven Effekt der Automationskonzepte fĂĽr die kontaktfreie Laserchirurgie
TableHop: an actuated fabric display using transparent electrodes
We present TableHop, a tabletop display that provides controlled self-actuated deformation and vibro-tactile feedback to an elastic fabric surface while retaining the ability for high-resolution visual projection. The TableHop surface is made of a highly stretchable pure spandex fabric that is electrostatically actuated using electrodes mounted on its underside. We use transparent indium tin oxide electrodes and high-voltage modulation to create controlled surface deformations. This setup actuates pixels and creates deformations in the fabric up to 5mm. Since the electrodes are transparent, the fabric surface can function as a diffuser for rear-projected visual images, and avoid occlusion by users. Users can touch and interact with the fabric to create expressive interactions as with any fabric based shape-changing interface. By using frequency modulation in the high-voltage circuit, we can also create localised tactile sensations on the user's finger-tip when touching the surface. We provide detailed simulation results of the shape of the surface deformation and the frequency of the haptic vibrations. These results can be used to build prototypes of different sizes and form-factors. We finally create a working prototype of TableHop that has 3040 cm surface area and uses a grid of 33 transparent electrodes. Our prototype uses a maximum of 2.2 mW and can create tactile vibrations of up to 20 . TableHop can be scaled to large interactive surfaces and integrated with other objects and devices. TableHop will improve user interaction experience on 2.5D deformable displays
- …