558 research outputs found
Magneto-Rheological Actuators for Human-Safe Robots: Modeling, Control, and Implementation
In recent years, research on physical human-robot interaction has received considerable attention. Research on this subject has led to the study of new control and actuation mechanisms for robots in order to achieve intrinsic safety. Naturally, intrinsic safety is only achievable in kinematic structures that exhibit low output impedance. Existing solutions for reducing impedance are commonly obtained at the expense of reduced performance, or significant increase in mechanical complexity. Achieving high performance while guaranteeing safety seems to be a challenging goal that necessitates new actuation technologies in future generations of human-safe robots.
In this study, a novel two degrees-of-freedom safe manipulator is presented. The manipulator uses magneto-rheological fluid-based actuators. Magneto-rheological actuators offer low inertia-to-torque and mass-to-torque ratios which support their applications in human-friendly actuation. As a key element in the design of the manipulator, bi-directional actuation is attained by antagonistically coupling MR actuators at the joints. Antagonistically coupled MR actuators at the joints allow using a single motor to drive multiple joints. The motor is located at the base of the manipulator in order to further reduce the overall weight of the robot. Due to the unique characteristic of MR actuators, intrinsically safe actuation is achieved without compromising high quality actuation. Despite these advantages, modeling and control of MR actuators present some challenges. The antagonistic configuration of MR actuators may result in limit cycles in some cases when the actuator operates in the position control loop. To study the possibility of limit cycles, describing function method is employed to obtain the conditions under which limit cycles may occur in the operation of the system. Moreover, a connection between the amplitude and the frequency of the potential limit cycles and the system parameters is established to provide an insight into the design of the actuator as well as the controller. MR actuators require magnetic fields to control their output torques. The application of magnetic field however introduces hysteresis in the behaviors of MR actuators. To this effect, an adaptive model is developed to estimate the hysteretic behavior of the actuator. The effectiveness of the model is evaluated by comparing its results with those obtained using the Preisach model. These results are then extended to an adaptive control scheme in order to compensate for the effect of hysteresis. In both modeling and control, stability of proposed schemes are evaluated using Lyapunov method, and the effectiveness of the proposed methods are validated with experimental results
Hybrid Magneto-Rheological Actuators for Human Friendly Robotic Manipulators
In recent years, many developments in the field of the physical human robot interaction (pHRI) have been witnessed and significant attentions have been given to the subject of safety within the interactive environments. Ensuring the safety has led to the design of the robots that are physically unable to hurt humans. However, Such systems commonly suffer from the safety-performance trade-off. Magneto-Rheological (MR) fluids are a special class of fluids that exhibit variable yield stress with respect to an applied magnetic field. Devices developed with such fluids are known to provide the prerequisite requirements of intrinsic safe actuation while maintaining the dynamical performance of the actuator.
In this study, a new concept for generating magnetic field in Magneto-Rheological (MR) clutches is presented. The main rationale behind this concept is to divide the magnetic field generation into two parts using an electromagnetic coil and a permanent magnet. The main rationale behind this concept is to utilize a hybrid combination of electromagnetic coil and a permanent magnet. The combination of permanent magnets and electromagnetic coils in Hybrid Magneto-Rheological (HMR) clutches allows to distribute the magnetic field inside an MR clutch more uniformly. Moreover, The use of a permanent magnet dramatically reduces the mass of MR clutches for a given value of the nominal torque that results in developing higher torque-to-mass ratio. High torque-to-mass and torque-to-inertia ratios in HMR clutches promotes the use of these devices in human-friendly actuation
Conception et évaluation d'actionneurs à embrayages magnétorhéologiques pour la robotique collaborative
La robotique collaborative se démarque de la robotique industrielle par sa sécurité dans le but de travailler en collaboration avec les humains. Toutefois, la majorité des robots collaboratifs sériels reposent sur un actionnement à haut ratio de réduction, ce qui augmente considérablement la masse reflétée à l’effecteur du robot, et donc, nuit à la sécurité. Pour pallier cette masse reflétée et maintenir un seuil minimal de sécurité, les vitesses d’opération sont abaissées, nuisant ainsi directement à la productivité des entreprises. Afin de minimiser la masse reflétée à l’effecteur, les masses des actionneurs ainsi que leur inertie reflétée doivent être minimisés. Les embrayages à fluide magnétorhéologique (MR) maintenus en glissement continus découplent l’inertie provenant de la source de puissance, souvent un moteur et un réducteur, offrant ainsi un actionneur possédant un haut rapport couple-inertie. Toutefois, les embrayages MR, utilisés de façon antagoniste, ajoutent des composantes à l’actionneur ce qui réduit la densité de couple, et donc, augmente la masse reflétée à l’effecteur du robot. Certains actionneurs MR [1–3] ont été développés, mais leur basse densité de couple contrebalance leur faible inertie lorsqu’utilisés comme actionneurs aux articulations de robots collaboratifs sériels. Cette constatation a mené à ma question de recherche : Comment profiter de la faible inertie des actionneurs MR pour maximiser les performances dynamiques des robots collaboratifs sériels?
L’objectif de ce projet de recherche vise donc à étudier le potentiel des embrayages MR en robotique collaborative. Pour ce faire, deux architectures MR sont développées et testées expérimentalement. La première architecture consiste en une articulation robotisée modulaire comportant des embrayages MR en glissement continu et possédant un rapport couple/masse et une taille équivalente à l’actionneur d’Universal Robots (UR) de couple égal, mais possédant un rapport couple/inertie 150 fois supérieur. À l’intérieur de l’articulation, deux chaines de puissance (2 moteurs et 2 embrayages MR) indépendantes se rejoignent à la sortie du joint offrant ainsi une redondance et augmentant la densité de couple comparativement à une architecture standard (1 moteur pour 2 embrayages MR).
La deuxième architecture étudiée consiste en un actionnement délocalisé du robot où les embrayages MR sont situés à la base du robot et une transmission hydrostatique à membranes déroulantes achemine la puissance aux articulations. Cette architecture a été testée expérimentalement dans un contexte de bras robotisé surnuméraire. Contrairement à l’articulation MR, cette architecture n’offre pas une modularité habituellement recherchée en robotique sérielle, mais offre la possibilité de réduire l’inertie de la structure avec la délocalisation de l’actionnement.
Finalement, les deux architectures développées ont été comparées à une architecture standard (haut ratio avec réducteur harmonique) afin de situer le potentiel du MR en robotique collaborative. Cette analyse théorique a démontré que pour un robot collaboratif sériel à 6 degrés de liberté, les architectures MR ont le potentiel d’accélérer 6 et 3 fois plus (respectivement) que le robot standard d’UR, composé d’actionneurs à hauts ratios
Design, Modelling, and Control of a Reconfigurable Rotary Series Elastic Actuator with Nonlinear Stiffness for Assistive Robots
In assistive robots, compliant actuator is a key component in establishing
safe and satisfactory physical human-robot interaction (pHRI). The performance
of compliant actuators largely depends on the stiffness of the elastic element.
Generally, low stiffness is desirable to achieve low impedance, high fidelity
of force control and safe pHRI, while high stiffness is required to ensure
sufficient force bandwidth and output force. These requirements, however, are
contradictory and often vary according to different tasks and conditions. In
order to address the contradiction of stiffness selection and improve
adaptability to different applications, we develop a reconfigurable rotary
series elastic actuator with nonlinear stiffness (RRSEAns) for assistive
robots. In this paper, an accurate model of the reconfigurable rotary series
elastic element (RSEE) is presented and the adjusting principles are
investigated, followed by detailed analysis and experimental validation. The
RRSEAns can provide a wide range of stiffness from 0.095 Nm/deg to 2.33 Nm/deg,
and different stiffness profiles can be yielded with respect to different
configuration of the reconfigurable RSEE. The overall performance of the
RRSEAns is verified by experiments on frequency response, torque control and
pHRI, which is adequate for most applications in assistive robots.
Specifically, the root-mean-square (RMS) error of the interaction torque
results as low as 0.07 Nm in transparent/human-in-charge mode, demonstrating
the advantages of the RRSEAns in pHRI
Design of a Haptic Interface for Medical Applications using Magneto-Rheological Fluid based Actuators
This thesis reports on the design, construction, and evaluation of a prototype two degrees-of-freedom (DOF) haptic interface, which takes advantage of Magneto-Rheological Fluid (MRF) based clutches for actuation. Haptic information provides important cues in teleoperated systems and enables the user to feel the interaction with a remote or virtual environment during teleoperation. The two main objectives in designing a haptic interface are stability and transparency. Indeed, deficiencies in these factors in haptics-enabled telerobotic systems has the introduction of haptics in medical environments where safety and reliability are prime considerations. An actuator with poor dynamics, high inertia, large size, and heavy weight can significantly undermine the stability and transparency of a teleoperated system. In this work, the potential benefits of MRF-based actuators to the field of haptics in medical applications are studied. Devices developed with such fluids are known to possess superior mechanical characteristics over conventional servo systems. These characteristics significantly contribute to improved stability and transparency of haptic devices. This idea is evaluated and verified through both theoretical and experimental points of view. The design of a small-scale MRF-based clutch, suitable for a multi-DOF haptic interface, is discussed and its performance is compared with conventional servo systems. This design is developed into four prototype clutches. In addition, a closed-loop torque control strategy is presented. The feedback signal used in this control scheme comes from the magnetic field acquired from embedded Hall sensors in the clutch. The controller uses this feedback signal to compensate for the nonlinear behavior using an estimated model, based on Artificial Neural Networks. Such a control strategy eliminates the need for torque sensors for providing feedback signals. The performance of the developed design and the effectiveness of the proposed modeling and control techniques are experimentally validated. Next, a 2-DOF haptic interface based on a distributed antagonistic configuration of MRF-based clutches is constructed for a class of medical applications. This device is incorporated in a master-slave teleoperation setup that is used for applications involving needle insertion and soft-tissue palpation. Phantom and in vitro animal tissue were used to assess the performance of the haptic interface. The results show a great potential of MRF-based actuators for integration in haptic devices for medical interventions that require reliable, safe, accurate, highly transparent, and stable force reflection
Electronic/electric technology benefits study
The benefits and payoffs of advanced electronic/electric technologies were investigated for three types of aircraft. The technologies, evaluated in each of the three airplanes, included advanced flight controls, advanced secondary power, advanced avionic complements, new cockpit displays, and advanced air traffic control techniques. For the advanced flight controls, the near term considered relaxed static stability (RSS) with mechanical backup. The far term considered an advanced fly by wire system for a longitudinally unstable airplane. In the case of the secondary power systems, trades were made in two steps: in the near term, engine bleed was eliminated; in the far term bleed air, air plus hydraulics were eliminated. Using three commercial aircraft, in the 150, 350, and 700 passenger range, the technology value and pay-offs were quantified, with emphasis on the fiscal benefits. Weight reductions deriving from fuel saving and other system improvements were identified and the weight savings were cycled for their impact on TOGW (takeoff gross weight) and upon the performance of the airframes/engines. Maintenance, reliability, and logistic support were the other criteria
Recommended from our members
Performance and manufacturing considerations for series elastic actuators
Robots are becoming an integral part of our lives. We are already physically connected with them through many robotic applications such as exoskeletons in military, orthosis devices in health care, collaborative robots in industry, etc. While the integration of robots improves the quality of human life, it still poses a safety concern during the physical human-robot interaction. Series Elastic Actuators (SEAs) play an important role in improving the safety of human-robot interaction and collaboration. Considering the fast expansion of robotic applications in our lives and the safety benefits of SEAs, it is conceivable that SEAs are going to play an important role in robotic applications in every aspect of human life. This dissertation focuses on reducing the cost, simplifying the use and improving the performance of SEAs. The first research focus in this dissertation is to reduce the cost of SEAs. Robots are successful in reducing production and service costs when used but the capital cost of robot installations are very high. As robotics research shifts to safe robotic applications, reducing the cost of SEAs will greatly help to deploy this technology in more robotic applications and to increase their accessibility to a broader range of researchers and educators. With this motivation, I present a case study on reducing the cost of a SEA while maintaining high force and position control performance and industrial grade service life. The second research focus in this dissertation is to simplify the laborious gain selection process of the cascaded controllers of SEAs. In order to simplify the gain selection process of the impedance controllers of SEAs, an optimal feedback gain selection methodology was developed. Using this method, the feedback gains of the cascaded PD-type impedance controllers of SEAs can easily be calibrated. The developed method allows the users to find the highest feedback gains for a desired phase-margin. Beyond the low-cost realization and simple controller tuning of SEAs, performance improvements on SEAs are possible utilizing the series elasticity in these actuators. As the third research focus in this dissertation, a sequential convex optimization-based motion planning technique is developed in order to improve the joint velocity capabilities of SEAs with nonlinearities. By using this method, higher joint velocities, that are not achievable with the rigid counterparts of SEAs can be achievedMechanical Engineerin
- …