30 research outputs found

    Diseños de capa cruzada para redes inalámbricas de área corporal energéticamente eficientes: una revisión

    Get PDF
    RESUMEN: El diseño de capa cruzada se considera una poderosa alternativa para dar solución a las complejidades introducidas por las comunicaciones inalámbricas en redes de área corporal (WBAN), donde el modelo clásico de comunicaciones no ha exhibido un desempeño adecuado. Respecto al problema puntual de consumo de energía, hemos preparado la presente revisión de las publicaciones más relevantes que tratan la eficiencia energética para WBAN usando diseño de capa cruzada. En este artículo se proporciona una revisión exhaustiva de los avances en aproximaciones, protocolos y optimizaciones de capa cruzada cuyo objetivo es incrementar el tiempo de vida de las redes WBAN mediante el ahorro de energía. Luego, se discute los aspectos relevantes y deficiencias de las técnicas de capa cruzada energéticamente eficientes. Además, se introducen aspectos de investigación abiertos y retos en el diseño de capa cruzada para WBAN. En esta revisión proponemos una taxonomía de las aproximaciones de capa cruzada, de modo que las técnicas revisadas se ajustan en categorías de acuerdo a los protocolos involucrados en el diseño. Una clasificación novedosa se incluye para hacer claridad en los conceptos teóricos involucrados en cada esquema de capa cruzada y para luego agrupar aproximaciones similares evidenciando las diferencias con otras técnicas entre sí. Nuestras conclusiones consideran los aspectos de movilidad y modelamiento del canal en escenarios de WBAN como las direcciones para futura investigación en WBAN y en aplicaciones de telemedicina.ABSTRACT: Cross-layer design is considered a powerful alternative to solve the complexities of wireless communication in wireless body area networks (WBAN), where the classical communication model has been shown to be inaccurate. Regarding the energy consumption problem, we have prepared a current survey of the most relevant scientific publications on energy-efficient cross-layer design for WBAN. In this paper, we provide a comprehensive review of the advances in cross-layer approaches, protocols and optimizations aimed at increasing the network lifetime by saving energy in WBANs. Subsequently, we discuss the relevant aspects and shortcomings of these energy-efficient cross-layer techniques and point out the open research issues and challenges in WBAN cross-layer design. In this survey, we propose a taxonomy for cross-layer approaches to fit them into categories based on the protocols involved in the cross-layer scheme. A novel classification is included to clarify the theoretical concepts behind each cross-layer scheme; and to group similar approaches by establishing their differences from the other strategies reviewed. Our conclusion considers the aspects of mobility and channel modeling in WBAN scenarios as the directions of future cross-layer research for WBAN and telemedicine applications

    A comprehensive review of wireless body area network

    Get PDF
    Recent development and advancement of information and communication technologies facilitate people in different dimensions of life. Most importantly, in the healthcare industry, this has become more and more involved with the information and communication technology-based services. One of the most important services is monitoring of remote patients, that enables the healthcare providers to observe, diagnose and prescribe the patients without being physically present. The advantage of miniaturization of sensor technologies gives the flexibility of installing in, on or off the body of patients, which is capable of forwarding physiological data wirelessly to remote servers. Such technology is named as Wireless Body Area Network (WBAN). In this paper, WBAN architecture, communication technologies for WBAN, challenges and different aspects of WBAN are illustrated. This paper also describes the architectural limitations of existing WBAN communication frameworks. blueFurthermore, implementation requirements are presented based on IEEE 802.15.6 standard. Finally, as a source of motivation towards future development of research incorporating Software Defined Networking (SDN), Energy Harvesting (EH) and Blockchain technology into WBAN are also provided

    Wireless Body Area Network (WBAN): A Survey on Reliability, Fault Tolerance, and Technologies Coexistence

    Get PDF
    Wireless Body Area Network (WBAN) has been a key element in e-health to monitor bodies. This technology enables new applications under the umbrella of different domains, including the medical field, the entertainment and ambient intelligence areas. This survey paper places substantial emphasis on the concept and key features of the WBAN technology. First, the WBAN concept is introduced and a review of key applications facilitated by this networking technology is provided. The study then explores a wide variety of communication standards and methods deployed in this technology. Due to the sensitivity and criticality of the data carried and handled by WBAN, fault tolerance is a critical issue and widely discussed in this paper. Hence, this survey investigates thoroughly the reliability and fault tolerance paradigms suggested for WBANs. Open research and challenging issues pertaining to fault tolerance, coexistence and interference management and power consumption are also discussed along with some suggested trends in these aspect

    A reliable trust-aware reinforcement learning based routing protocol for wireless medical sensor networks.

    Get PDF
    Interest in the Wireless Medical Sensor Network (WMSN) is rapidly gaining attention thanks to recent advances in semiconductors and wireless communication. However, by virtue of the sensitive medical applications and the stringent resource constraints, there is a need to develop a routing protocol to fulfill WMSN requirements in terms of delivery reliability, attack resiliency, computational overhead and energy efficiency. This doctoral research therefore aims to advance the state of the art in routing by proposing a lightweight, reliable routing protocol for WMSN. Ensuring a reliable path between the source and the destination requires making trustaware routing decisions to avoid untrustworthy paths. A lightweight and effective Trust Management System (TMS) has been developed to evaluate the trust relationship between the sensor nodes with a view to differentiating between trustworthy nodes and untrustworthy ones. Moreover, a resource-conservative Reinforcement Learning (RL) model has been proposed to reduce the computational overhead, along with two updating methods to speed up the algorithm convergence. The reward function is re-defined as a punishment, combining the proposed trust management system to defend against well-known dropping attacks. Furthermore, with a view to addressing the inborn overestimation problem in Q-learning-based routing protocols, we adopted double Q-learning to overcome the positive bias of using a single estimator. An energy model is integrated with the reward function to enhance the network lifetime and balance energy consumption across the network. The proposed energy model uses only local information to avoid the resource burdens and the security concerns of exchanging energy information. Finally, a realistic trust management testbed has been developed to overcome the limitations of using numerical analysis to evaluate proposed trust management schemes, particularly in the context of WMSN. The proposed testbed has been developed as an additional module to the NS-3 simulator to fulfill usability, generalisability, flexibility, scalability and high-performance requirements

    Wearable Wireless Devices

    Get PDF
    No abstract available

    Wearable Wireless Devices

    Get PDF
    No abstract available

    A MAC protocol for quality of service provisioning in adaptive biomedical wireless sensor networks

    Get PDF
    Doctorate program on Electronics and Computer EngineeringNew healthcare solutions are being explored to improve the quality of care and the quality of life of patients, as well as the sustainability and efficiency of the healthcare services. In this context, wireless sensor networks (WSNs) constitute a key technology for closing the loop between patients and healthcare providers, as WSNs provide sensing ability, as well as mobility and portability, essential characteristics for wide acceptance of wireless healthcare technology. Despite the recent advances in the field, the wide adoption of healthcare WSNs is still conditioned by quality of service (QoS) issues, namely at the medium access control (MAC) level. MAC protocols currently available for WSNs are not able to provide the required QoS to healthcare applications in scenarios of medical emergency or intensive medical care. To cover this shortage, the present work introduces a MAC protocol with novel concepts to assure the required QoS regarding the data transmission robustness, packet delivery deadline, bandwidth efficiency, and energy preservation. The proposed MAC protocol provides a new and efficient dynamic reconfiguration mechanism, so that relevant operational parameters may be redefined dynamically in accordance with the patients’ clinical state. The protocol also provides a channel switching mechanism and the capacity of forwarding frames in two-tier network structures. To test the performance of the proposed MAC protocol and compare it with other MAC protocols, a simulation platform was implemented. In order to validate the simulation results, a physical testbed was implemented to replicate the tests and verify the results. Sensor nodes were specifically designed and assembled to implement this physical testbed. New healthcare solutions are being explored to improve the quality of care and the quality of life of patients, as well as the sustainability and efficiency of the healthcare services. In this context, wireless sensor networks (WSNs) constitute a key technology for closing the loop between patients and healthcare providers, as WSNs provide sensing ability, as well as mobility and portability, essential characteristics for wide acceptance of wireless healthcare technology. Despite the recent advances in the field, the wide adoption of healthcare WSNs is still conditioned by quality of service (QoS) issues, namely at the medium access control (MAC) level. MAC protocols currently available for WSNs are not able to provide the required QoS to healthcare applications in scenarios of medical emergency or intensive medical care. To cover this shortage, the present work introduces a MAC protocol with novel concepts to assure the required QoS regarding the data transmission robustness, packet delivery deadline, bandwidth efficiency, and energy preservation. The proposed MAC protocol provides a new and efficient dynamic reconfiguration mechanism, so that relevant operational parameters may be redefined dynamically in accordance with the patients’ clinical state. The protocol also provides a channel switching mechanism and the capacity of forwarding frames in two-tier network structures. To test the performance of the proposed MAC protocol and compare it with other MAC protocols, a simulation platform was implemented. In order to validate the simulation results, a physical testbed was implemented to replicate the tests and verify the results. Sensor nodes were specifically designed and assembled to implement this physical testbed. Preliminary tests using the simulation and physical platforms showed that simulation results diverge significantly from reality, if the performance of the WSN software components is not considered. Therefore, a parametric model was developed to reflect the impact of this aspect on a physical WSN. Simulation tests using the parametric model revealed that the results match satisfactorily those obtained in reality. After validating the simulation platform, comparative tests against IEEE 802.15.4, a prominent standard used in many wireless healthcare systems, showed that the proposed MAC protocol leads to a performance increase regarding diverse QoS metrics, such as packet loss and bandwidth efficiency, as well as scalability, adaptability, and power consumption. In this way, AR-MAC is a valuable contribution to the deployment of wireless e-health technology and related applications.Novas soluções de cuidados de saúde estão a ser exploradas para melhorar a qualidade de tratamento e a qualidade de vida dos pacientes, assim como a sustentabilidade e eficiência dos serviços de cuidado de saúde. Neste contexto, as redes de sensores sem fios (wireless sensor networks - WSN) são uma tecnologia chave para fecharem o ciclo entre os pacientes e os prestadores de cuidados de saúde, uma vez que as WSNs proporcionam não só capacidade sensorial mas também mobilidade e portabilidade, caracteristicas essenciais para a aceitação à larga escala da tecnologia dos cuidados de saúde sem fios. Apesar dos avanços recentes na área, a aceitação genérica das WSNs de cuidados de saúde ainda está condicionada por aspectos relacionados com a qualidade de serviço (quality of service - QoS), nomeadamente ao nível do controlo de acesso ao meio (medium access control - MAC). Os protocolos MAC actualmente disponíveis para WSNs são incapazes de fornecer a QoS desejada pelas aplicações médicas em cenários de emergência ou cuidados médicos intensivos. Para suprimir esta carência, o presente trabalho apresenta um protocolo MAC com novos conceitos a fim de assegurar a QoS respeitante à robustez de transmissão de dados, ao limite temporal da entrega de pacotes, à utilização da largura de banda e à preservação da energia eléctrica. O protocolo MAC proposto dispõe de um novo e eficiente mecanismo de reconfiguração para que os parâmetros operacionais relevantes possam ser redefinidos dinamicamente de acordo com o estado de saúde do paciente. O protocolo também oferece um mecanismo autónomo de comutação de canal, bem como a capacidade de encaminhar pacotes em redes de duas camadas. Para testar o desempenho do protocolo MAC proposto e compará-lo com outros protocolos MAC foi implementada uma plataforma de simulação. A fim de validar os resultados da simulação foi também implementada uma plataforma física para permitir replicar os testes e verificar os resultados. Esta plataforma física inclui nós sensoriais concebidos e construídos de raiz para o efeito. Testes preliminares usando as plataformas de simulação e física mostraram que os resultados de simulação divergem significativamente da realidade, caso o desempenho dos componentes do software presentes nos componentes da WSN não seja considerado. Por conseguinte, desenvolveu-se um modelo paramétrico para reflectir o impacto deste aspecto numa WSN real. Testes de simulação efectuados com o modelo paramétrico apresentaram resultados muito satisfatórios quando comparados com os obtidos na realidade. Uma vez validada a plataforma de simulação, efectuaram-se testes comparativos com a norma IEEE 802.15.4, proeminentemente usada em projectos académicos de cuidados de saúde sem fios. Os resultados mostraram que o protocolo MAC conduz a um desempenho superior no tocante a diversas métricas QoS, tais como perdas de pacotes e utilização de largura de banda, bem como no respeitante à escalabilidade, adaptabilidade e consumo de energia eléctrica. Assim sendo, o protocolo MAC proposto representa um valioso contributo para a concretização efectiva dos cuidados de saúde sem fios e suas aplicações

    Resource Management in E-health Systems

    Get PDF
    E-health systems are the information and communication systems deployed to improve quality and efficiency of public health services. Within E-health systems, wearable sensors are deployed to monitor physiology information not only in hospitals, but also in our daily lives under all types of activities; wireless body area networks (WBANs) are adopted to transmit physiology information to smartphones; and cloud servers are utilized for timely diagnose and disease treatment. The integrated services provided by E-health systems could be more convenient, reliable, patient centric and bring more economic healthcare services. Despite of many benefits, e-health systems face challenges among which resource management is the most important one as wearable sensors are energy and computing capability limited, and medical information has stringent quality of service (QoS) requirements in terms of delay and reliability. This thesis presents resource management mechanisms, including transmission power allocation schemes for wearable sensors, Medium Access Control (MAC) for WBANs, and resource sharing schemes among cloud networks, that can efficiently exploit the limited resources to achieve satisfactory QoS. First, we address how wearable sensors could energy efficiently transmit medical information with stringent QoS requirements to a smart phone. We first investigate how to provide worst-case delay provisioning for vital physiology information. Sleep scheduling and opportunistic channel access are exploited to reduce energy consumption in idle listening and increase energy efficiency. Considering dynamic programming suffers from curse of dimensionality, Lyapunov optimization formulation is established to derive a low complexity two-step transmission power allocation algorithm. We analyze the conditions under which the proposed algorithm could guarantee worst-case delay. We then investigate the impacts of peak power constraint and statistical QoS provisioning. An optimal transmission power allocation scheme under a peak power constraint is derived, and followed by an efficient calculation method. Applying duality gap analysis, we characterize the upper bound of the extra average transmission power incurred due a peak power constraint. We demonstrate that when the peak power constraint is stringent, the proposed constant power scheme is suitable for wearable sensors for its performance is close to optimal. Further, we show that the peak power constraint is the bottleneck for wearable sensors to provide stringent statistical QoS provisioning. Second, WBANs can provide low-cost and timely healthcare services and are expected to be widely adopted in hospitals. We develop a centralized MAC layer resource management scheme for WBANs, with a focus on inter-WBAN interference mitigation and sensor power consumption reduction. Based on the channel state and buffer state information reported by smart phones deployed in each WBAN, channel access allocation is performed by a central controller to maximize the network throughput. Note that sensors have insufficient energy and computing capability to timely provide all the necessary information for channel resource management, which deteriorates the network performance. We exploit the temporal correlation of body area channel such that channel state reports from sensors are minimized. We then formulate the MAC design problem as a partially observable optimization problem and develop a myopic policy accordingly. Third, cloud computing is expected to meet the rising computing demands. Both private clouds, which aim at patients in their regions, and public clouds, which serve general public, are adopted. Reliability control and QoS provisioning are the core issues of private clouds and public clouds, respectively. A framework, which exploits the abundant resource of private clouds in time domain, to enable cooperation among private clouds and public clouds, is proposed. Considering the cost of service failure in e-health system, the first time failure probability is adopted as reliability measures for private clouds. An algorithm is proposed to minimize the failure probability, and is proven to be optimal. Then, we propose an e-health monitoring system with minimum service delay and privacy preservation by exploiting geo-distributed clouds. In the system, the resource management scheme enables the distributed cloud servers to cooperatively assign the servers to the requested users under a load balance condition. Thus, the service delay for users is minimized. In addition, a traffic shaping algorithm is proposed, which converts the user health data traffic to the non-health data traffic such that the capability of traffic analysis attacks is largely reduced. In summary, we believe the research results developed in this dissertation can provide insights for efficient transmission power allocation for wearable sensor, can offer practical MAC layer solutions for WBANs in hospital environment, and can improve the QoS provisioning provided by cloud networks in e-health systems

    Data fusion of relative movement in fast, repetitive-action sports using body wireless area networks

    Get PDF
    Rowing is an intensive, all-body sport, where bad technique can lead to injury. Crew cohesion, particularly timing, is vital to the performance of the boat. The coaching process, and injury prevention, could be enhanced if data relating to the movement of the oarsmen could be collected, without hindrance to the oarsmen, during on-water training. Literature until recently has concentrated upon boat-centric measurement. Advances in wireless technology have made feasible the collection of data from multiple physically separate sites, including on-body. After analysis of candidate radio standards, a Zigbee wireless Body Sensor Network (BSN) was designed and developed to synchronously collect data from several sensors across the wireless BSN. By synchronising sensor nodes via scheduled synchronising messages from the central coordinating node, synchronisation within 0.79msec ±0.39ms was achieved. Minimisation of the on-time of the sensor node radios currently extends the battery life by a factor of 5. Acceleration and muscle activity data collected using the wireless BSN was compared to data synchronously collected using proven motion analysis techniques to validate the system. Synchronous muscle activity data was collected via the wireless BSN from several muscles during both land-based and on-water rowing and the results compared. The system was proven to facilitate the identification of bad rowing technique, as well as differences in muscle recruitment between land- and water-based rowing. Data collection from a rowing crew was also demonstrated, and their muscle activity and inter-crew timing analysed. With an additional sensor node upon the boat, it is possible to correlate acceleration and muscle activity from the oarsman with acceleration of the boat itself. A novel, power-optimised wireless sensor network has been designed and demonstrated to facilitate on-water rowing monitoring that can be extended beyond single oarsman measurements to analyse the interaction and cohesion of a crew and their impact upon boat performance
    corecore