2,399 research outputs found
Enhancing Compressed Sensing 4D Photoacoustic Tomography by Simultaneous Motion Estimation
A crucial limitation of current high-resolution 3D photoacoustic tomography
(PAT) devices that employ sequential scanning is their long acquisition time.
In previous work, we demonstrated how to use compressed sensing techniques to
improve upon this: images with good spatial resolution and contrast can be
obtained from suitably sub-sampled PAT data acquired by novel acoustic scanning
systems if sparsity-constrained image reconstruction techniques such as total
variation regularization are used. Now, we show how a further increase of image
quality can be achieved for imaging dynamic processes in living tissue (4D
PAT). The key idea is to exploit the additional temporal redundancy of the data
by coupling the previously used spatial image reconstruction models with
sparsity-constrained motion estimation models. While simulated data from a
two-dimensional numerical phantom will be used to illustrate the main
properties of this recently developed
joint-image-reconstruction-and-motion-estimation framework, measured data from
a dynamic experimental phantom will also be used to demonstrate their potential
for challenging, large-scale, real-world, three-dimensional scenarios. The
latter only becomes feasible if a carefully designed combination of tailored
optimization schemes is employed, which we describe and examine in more detail
Quantifying admissible undersampling for sparsity-exploiting iterative image reconstruction in X-ray CT
Iterative image reconstruction (IIR) with sparsity-exploiting methods, such
as total variation (TV) minimization, investigated in compressive sensing (CS)
claim potentially large reductions in sampling requirements. Quantifying this
claim for computed tomography (CT) is non-trivial, because both full sampling
in the discrete-to-discrete imaging model and the reduction in sampling
admitted by sparsity-exploiting methods are ill-defined. The present article
proposes definitions of full sampling by introducing four sufficient-sampling
conditions (SSCs). The SSCs are based on the condition number of the system
matrix of a linear imaging model and address invertibility and stability. In
the example application of breast CT, the SSCs are used as reference points of
full sampling for quantifying the undersampling admitted by reconstruction
through TV-minimization. In numerical simulations, factors affecting admissible
undersampling are studied. Differences between few-view and few-detector bin
reconstruction as well as a relation between object sparsity and admitted
undersampling are quantified.Comment: Revised version that was submitted to IEEE Transactions on Medical
Imaging on 8/16/201
Spatio-temporal wavelet regularization for parallel MRI reconstruction: application to functional MRI
Parallel MRI is a fast imaging technique that enables the acquisition of
highly resolved images in space or/and in time. The performance of parallel
imaging strongly depends on the reconstruction algorithm, which can proceed
either in the original k-space (GRAPPA, SMASH) or in the image domain
(SENSE-like methods). To improve the performance of the widely used SENSE
algorithm, 2D- or slice-specific regularization in the wavelet domain has been
deeply investigated. In this paper, we extend this approach using 3D-wavelet
representations in order to handle all slices together and address
reconstruction artifacts which propagate across adjacent slices. The gain
induced by such extension (3D-Unconstrained Wavelet Regularized -SENSE:
3D-UWR-SENSE) is validated on anatomical image reconstruction where no temporal
acquisition is considered. Another important extension accounts for temporal
correlations that exist between successive scans in functional MRI (fMRI). In
addition to the case of 2D+t acquisition schemes addressed by some other
methods like kt-FOCUSS, our approach allows us to deal with 3D+t acquisition
schemes which are widely used in neuroimaging. The resulting 3D-UWR-SENSE and
4D-UWR-SENSE reconstruction schemes are fully unsupervised in the sense that
all regularization parameters are estimated in the maximum likelihood sense on
a reference scan. The gain induced by such extensions is illustrated on both
anatomical and functional image reconstruction, and also measured in terms of
statistical sensitivity for the 4D-UWR-SENSE approach during a fast
event-related fMRI protocol. Our 4D-UWR-SENSE algorithm outperforms the SENSE
reconstruction at the subject and group levels (15 subjects) for different
contrasts of interest (eg, motor or computation tasks) and using different
parallel acceleration factors (R=2 and R=4) on 2x2x3mm3 EPI images.Comment: arXiv admin note: substantial text overlap with arXiv:1103.353
- …