1,722 research outputs found
Bayesian multi--dipole localization and uncertainty quantification from simultaneous EEG and MEG recordings
We deal with estimation of multiple dipoles from combined MEG and EEG
time--series. We use a sequential Monte Carlo algorithm to characterize the
posterior distribution of the number of dipoles and their locations. By
considering three test cases, we show that using the combined data the method
can localize sources that are not easily (or not at all) visible with either of
the two individual data alone. In addition, the posterior distribution from
combined data exhibits a lower variance, i.e. lower uncertainty, than the
posterior from single device.Comment: 4 pages, 3 figures -- conference paper from EMBEC 2017, Tampere,
Finlan
Inverse Modeling for MEG/EEG data
We provide an overview of the state-of-the-art for mathematical methods that
are used to reconstruct brain activity from neurophysiological data. After a
brief introduction on the mathematics of the forward problem, we discuss
standard and recently proposed regularization methods, as well as Monte Carlo
techniques for Bayesian inference. We classify the inverse methods based on the
underlying source model, and discuss advantages and disadvantages. Finally we
describe an application to the pre-surgical evaluation of epileptic patients.Comment: 15 pages, 1 figur
Influence of metallic artifact filtering on MEG signals for source localization during interictal epileptiform activity
Objective. Medical intractable epilepsy is a common condition that affects 40% of epileptic patients that generally have to undergo resective surgery. Magnetoencephalography (MEG) has been increasingly used to identify the epileptogenic foci through equivalent current dipole (ECD) modeling, one of the most accepted methods to obtain an accurate localization of interictal epileptiform discharges (IEDs). Modeling requires that MEG signals are adequately preprocessed to reduce interferences, a task that has been greatly improved by the use of blind source separation (BSS) methods. MEG recordings are highly sensitive to metallic interferences originated inside the head by implanted intracranial electrodes, dental prosthesis, etc and also coming from external sources such as pacemakers or vagal stimulators. To reduce these artifacts, a BSS-based fully automatic procedure was recently developed and validated, showing an effective reduction of metallic artifacts in simulated and real signals (Migliorelli et al 2015 J. Neural Eng. 12 046001). The main objective of this study was to evaluate its effects in the detection of IEDs and ECD modeling of patients with focal epilepsy and metallic interference. Approach. A comparison between the resulting positions of ECDs was performed: without removing metallic interference; rejecting only channels with large metallic artifacts; and after BSS-based reduction. Measures of dispersion and distance of ECDs were defined to analyze the results. Main results. The relationship between the artifact-to-signal ratio and ECD fitting showed that higher values of metallic interference produced highly scattered dipoles. Results revealed a significant reduction on dispersion using the BSS-based reduction procedure, yielding feasible locations of ECDs in contrast to the other two approaches. Significance. The automatic BSS-based method can be applied to MEG datasets affected by metallic artifacts as a processing step to improve the localization of epileptic foci.Postprint (published version
State-space solutions to the dynamic magnetoencephalography inverse problem using high performance computing
Determining the magnitude and location of neural sources within the brain
that are responsible for generating magnetoencephalography (MEG) signals
measured on the surface of the head is a challenging problem in functional
neuroimaging. The number of potential sources within the brain exceeds by an
order of magnitude the number of recording sites. As a consequence, the
estimates for the magnitude and location of the neural sources will be
ill-conditioned because of the underdetermined nature of the problem. One
well-known technique designed to address this imbalance is the minimum norm
estimator (MNE). This approach imposes an regularization constraint that
serves to stabilize and condition the source parameter estimates. However,
these classes of regularizer are static in time and do not consider the
temporal constraints inherent to the biophysics of the MEG experiment. In this
paper we propose a dynamic state-space model that accounts for both spatial and
temporal correlations within and across candidate intracortical sources. In our
model, the observation model is derived from the steady-state solution to
Maxwell's equations while the latent model representing neural dynamics is
given by a random walk process.Comment: Published in at http://dx.doi.org/10.1214/11-AOAS483 the Annals of
Applied Statistics (http://www.imstat.org/aoas/) by the Institute of
Mathematical Statistics (http://www.imstat.org
Magnetoencephalography in Stroke Recovery and Rehabilitation
Magnetoencephalography (MEG) is a non-invasive neurophysiological technique used to study the cerebral cortex. Currently, MEG is mainly used clinically to localize epileptic foci and eloquent brain areas in order to avoid damage during neurosurgery. MEG might, however, also be of help in monitoring stroke recovery and rehabilitation. This review focuses on experimental use of MEG in neurorehabilitation. MEG has been employed to detect early modifications in neuroplasticity and connectivity, but there is insufficient evidence as to whether these methods are sensitive enough to be used as a clinical diagnostic test. MEG has also been exploited to derive the relationship between brain activity and movement kinematics for a motor-based brain-computer interface. In the current body of experimental research, MEG appears to be a powerful tool in neurorehabilitation, but it is necessary to produce new data to confirm its clinical utility
Recommended from our members
EEG-Based Quantification of Cortical Current Density and Dynamic Causal Connectivity Generalized across Subjects Performing BCI-Monitored Cognitive Tasks.
Quantification of dynamic causal interactions among brain regions constitutes an important component of conducting research and developing applications in experimental and translational neuroscience. Furthermore, cortical networks with dynamic causal connectivity in brain-computer interface (BCI) applications offer a more comprehensive view of brain states implicated in behavior than do individual brain regions. However, models of cortical network dynamics are difficult to generalize across subjects because current electroencephalography (EEG) signal analysis techniques are limited in their ability to reliably localize sources across subjects. We propose an algorithmic and computational framework for identifying cortical networks across subjects in which dynamic causal connectivity is modeled among user-selected cortical regions of interest (ROIs). We demonstrate the strength of the proposed framework using a "reach/saccade to spatial target" cognitive task performed by 10 right-handed individuals. Modeling of causal cortical interactions was accomplished through measurement of cortical activity using (EEG), application of independent component clustering to identify cortical ROIs as network nodes, estimation of cortical current density using cortically constrained low resolution electromagnetic brain tomography (cLORETA), multivariate autoregressive (MVAR) modeling of representative cortical activity signals from each ROI, and quantification of the dynamic causal interaction among the identified ROIs using the Short-time direct Directed Transfer function (SdDTF). The resulting cortical network and the computed causal dynamics among its nodes exhibited physiologically plausible behavior, consistent with past results reported in the literature. This physiological plausibility of the results strengthens the framework's applicability in reliably capturing complex brain functionality, which is required by applications, such as diagnostics and BCI
- âŠ