208,588 research outputs found

    Dynamic Rigid Motion Estimation From Weak Perspective

    Get PDF
    “Weak perspective” represents a simplified projection model that approximates the imaging process when the scene is viewed under a small viewing angle and its depth relief is small relative to its distance from the viewer. We study how to generate dynamic models for estimating rigid 3D motion from weak perspective. A crucial feature in dynamic visual motion estimation is to decouple structure from motion in the estimation model. The reasons are both geometric-to achieve global observability of the model-and practical, for a structure independent motion estimator allows us to deal with occlusions and appearance of new features in a principled way. It is also possible to push the decoupling even further, and isolate the motion parameters that are affected by the so called “bas relief ambiguity” from the ones that are not. We present a novel method for reducing the order of the estimator by decoupling portions of the state space from the time evolution of the measurement constraint. We use this method to construct an estimator of full rigid motion (modulo a scaling factor) on a six dimensional state space, an approximate estimator for a four dimensional subset of the motion space, and a reduced filter with only two states. The latter two are immune to the bas relief ambiguity. We compare strengths and weaknesses of each of the schemes on real and synthetic image sequences

    Analysis of DCE-MRI Data using a Nonnegative Elastic Net

    Get PDF
    We present a nonnegative Elastic Net approach for the analysis of Dynamic Contrast-Enhanced Magnetic Resonance Imaging data. A multi-compartment approach is considered, which is translated into a (restricted) least square model selection problem. This is done by using a set of basis functions for a given set of candidate rate constants. The form of the basis functions is derived from a kinetic model and thus describes the contribution of some compartment. Using the Elastic Net estimator, we chose clusters of basis functions, and hence, rate constants of compartments. As further challenge, the estimator has to be restricted to positive regression parameters, which correspond to transfer rates of the compartments. The proposed estimation method is applied to an in-vivo data set

    Spatially regularized estimation for the analysis of DCE-MRI data

    Get PDF
    Competing compartment models of different complexities have been used for the quantitative analysis of Dynamic Contrast-Enhanced Magnetic Resonance Imaging data. We present a spatial Elastic Net approach that allows to estimate the number of compartments for each voxel such that the model complexity is not fixed a priori. A multi-compartment approach is considered, which is translated into a restricted least square model selection problem. This is done by using a set of basis functions for a given set of candidate rate constants. The form of the basis functions is derived from a kinetic model and thus describes the contribution of a specific compartment. Using a spatial Elastic Net estimator, we chose a sparse set of basis functions per voxel, and hence, rate constants of compartments. The spatial penalty takes into account the voxel structure of an image and performs better than a penalty treating voxels independently. The proposed estimation method is evaluated for simulated images and applied to an in-vivo data set

    Robust 3D Reconstruction of Dynamic Scenes From Single-Photon Lidar Using Beta-Divergences

    Get PDF
    In this paper, we present a new algorithm for fast, online 3D reconstruction of dynamic scenes using times of arrival of photons recorded by single-photon detector arrays. One of the main challenges in 3D imaging using single-photon lidar in practical applications is the presence of strong ambient illumination which corrupts the data and can jeopardize the detection of peaks/surface in the signals. This background noise not only complicates the observation model classically used for 3D reconstruction but also the estimation procedure which requires iterative methods. In this work, we consider a new similarity measure for robust depth estimation, which allows us to use a simple observation model and a non-iterative estimation procedure while being robust to mis-specification of the background illumination model. This choice leads to a computationally attractive depth estimation procedure without significant degradation of the reconstruction performance. This new depth estimation procedure is coupled with a spatio-temporal model to capture the natural correlation between neighboring pixels and successive frames for dynamic scene analysis. The resulting online inference process is scalable and well suited for parallel implementation. The benefits of the proposed method are demonstrated through a series of experiments conducted with simulated and real single-photon lidar videos, allowing the analysis of dynamic scenes at 325 m observed under extreme ambient illumination conditions.Comment: 12 page

    A Bayesian Hyperprior Approach for Joint Image Denoising and Interpolation, with an Application to HDR Imaging

    Full text link
    Recently, impressive denoising results have been achieved by Bayesian approaches which assume Gaussian models for the image patches. This improvement in performance can be attributed to the use of per-patch models. Unfortunately such an approach is particularly unstable for most inverse problems beyond denoising. In this work, we propose the use of a hyperprior to model image patches, in order to stabilize the estimation procedure. There are two main advantages to the proposed restoration scheme: Firstly it is adapted to diagonal degradation matrices, and in particular to missing data problems (e.g. inpainting of missing pixels or zooming). Secondly it can deal with signal dependent noise models, particularly suited to digital cameras. As such, the scheme is especially adapted to computational photography. In order to illustrate this point, we provide an application to high dynamic range imaging from a single image taken with a modified sensor, which shows the effectiveness of the proposed scheme.Comment: Some figures are reduced to comply with arxiv's size constraints. Full size images are available as HAL technical report hal-01107519v5, IEEE Transactions on Computational Imaging, 201

    Imaging of a fluid injection process using geophysical data - A didactic example

    Get PDF
    In many subsurface industrial applications, fluids are injected into or withdrawn from a geologic formation. It is of practical interest to quantify precisely where, when, and by how much the injected fluid alters the state of the subsurface. Routine geophysical monitoring of such processes attempts to image the way that geophysical properties, such as seismic velocities or electrical conductivity, change through time and space and to then make qualitative inferences as to where the injected fluid has migrated. The more rigorous formulation of the time-lapse geophysical inverse problem forecasts how the subsurface evolves during the course of a fluid-injection application. Using time-lapse geophysical signals as the data to be matched, the model unknowns to be estimated are the multiphysics forward-modeling parameters controlling the fluid-injection process. Properly reproducing the geophysical signature of the flow process, subsequent simulations can predict the fluid migration and alteration in the subsurface. The dynamic nature of fluid-injection processes renders imaging problems more complex than conventional geophysical imaging for static targets. This work intents to clarify the related hydrogeophysical parameter estimation concepts

    Quantifying Cancer Cell Receptors with Paired-Agent Fluorescent Imaging: a Novel Method to Account for Tissue Optical Property Effects.

    Get PDF
    Dynamic fluorescence imaging approaches can be used to estimate the concentration of cell surface receptorsin vivo. Kinetic models are used to generate the final estimation by taking the targeted imaging agent concentration as a function of time. However, tissue absorption and scattering properties cause the final readout signal to be on a different scale than the real fluorescent agent concentration. In paired-agent imaging approaches, simultaneous injection of a suitable control imaging agent with a targeted one can account for non-specific uptake and retention of the targeted agent. Additionally, the signal from the control agent can be a normalizing factor to correct for tissue optical property differences. In this study, the kinetic model used for paired-agent imaging analysis (i.e., simplified reference tissue model) is modified and tested in simulation and experimental data in a way that accounts for the scaling correction within the kinetic model fit to the data to ultimately extract an estimate of the targeted biomarker concentration
    corecore