1,443 research outputs found

    Simultaneous use of Individual and Joint Regularization Terms in Compressive Sensing: Joint Reconstruction of Multi-Channel Multi-Contrast MRI Acquisitions

    Get PDF
    Purpose: A time-efficient strategy to acquire high-quality multi-contrast images is to reconstruct undersampled data with joint regularization terms that leverage common information across contrasts. However, these terms can cause leakage of uncommon features among contrasts, compromising diagnostic utility. The goal of this study is to develop a compressive sensing method for multi-channel multi-contrast magnetic resonance imaging (MRI) that optimally utilizes shared information while preventing feature leakage. Theory: Joint regularization terms group sparsity and colour total variation are used to exploit common features across images while individual sparsity and total variation are also used to prevent leakage of distinct features across contrasts. The multi-channel multi-contrast reconstruction problem is solved via a fast algorithm based on Alternating Direction Method of Multipliers. Methods: The proposed method is compared against using only individual and only joint regularization terms in reconstruction. Comparisons were performed on single-channel simulated and multi-channel in-vivo datasets in terms of reconstruction quality and neuroradiologist reader scores. Results: The proposed method demonstrates rapid convergence and improved image quality for both simulated and in-vivo datasets. Furthermore, while reconstructions that solely use joint regularization terms are prone to leakage-of-features, the proposed method reliably avoids leakage via simultaneous use of joint and individual terms. Conclusion: The proposed compressive sensing method performs fast reconstruction of multi-channel multi-contrast MRI data with improved image quality. It offers reliability against feature leakage in joint reconstructions, thereby holding great promise for clinical use.Comment: 13 pages, 13 figures. Submitted for possible publicatio

    Screen-printed flexible MRI receive coils.

    Get PDF
    Magnetic resonance imaging is an inherently signal-to-noise-starved technique that limits the spatial resolution, diagnostic image quality and results in typically long acquisition times that are prone to motion artefacts. This limitation is exacerbated when receive coils have poor fit due to lack of flexibility or need for padding for patient comfort. Here, we report a new approach that uses printing for fabricating receive coils. Our approach enables highly flexible, extremely lightweight conforming devices. We show that these devices exhibit similar to higher signal-to-noise ratio than conventional ones, in clinical scenarios when coils could be displaced more than 18 mm away from the body. In addition, we provide detailed material properties and components performance analysis. Prototype arrays are incorporated within infant blankets for in vivo studies. This work presents the first fully functional, printed coils for 1.5- and 3-T clinical scanners

    Accelerated Imaging Techniques for Chemical Shift Magnetic Resonance Imaging

    Get PDF
    Chemical shift imaging is a method for the separation two or more chemical species. The cost of chemical shift encoding is increased acquisition time as multiple acquisitions are acquired at different echo times. Image acceleration techniques, typically parallel imaging, are often used to improve the spatial coverage and resolution. This thesis describes a new technique for estimating the signal to noise ratio for parallel imaging reconstructions and proposes new image reconstructions for accelerated chemical shift imaging using compressed sensing and/or parallel imaging for two applications: water-fat separation and metabolic imaging of hyperpolarized [1-13C] pyruvate. Spatially varying noise in parallel imaging reconstructions makes measurements of the signal to noise ratio, a commonly used metric for image for image quality, difficult. Existing approaches have limitations such as they are not applicable to all reconstructions, require significant computation time, or rely on repeated image acquisitions. A SNR estimation technique is proposed that does not exhibit these limitations. Water-fat imaging of highly undersampled datasets from the liver, calf, knee, and abdominal cavity are demonstrated using a customized IDEAL-SPGR pulse sequence and an integrated compressed sensing, parallel imaging, water-fat reconstruction. This method is shown to offer comparable image quality relative to fully sampled reference images for a range of acceleration factors. At high acceleration factors, this technique is shown to offer improved image quality when compared to the current standard of parallel imaging. Accelerated chemical shift imaging was demonstrated for metabolic of hyperpolarized [1-13C] pyruvate. Pyruvate, lactate, alanine, and bicarbonate images were reconstructed from undersampled datasets. Phantoms were used to validate this technique while retrospectively and prospectively accelerated 3D in vivo datasets were used to demonstrate. Alternatively, acceleration was also achieved through the use of a high performance magnetic field gradient set. This thesis addresses the inherently slow acquisition times of chemical shift imaging by examining the role compressed sensing and parallel imaging can be play in chemical shift imaging. An approach to SNR assessment for parallel imaging reconstruction is proposed and approaches to accelerated chemical shift imaging are described for applications in water-fat imaging and metabolic imaging of hyperpolarized [1-13C] pyruvate

    A Feasibility Study of Geometric-Decomposition Coil Compression in MRI Radial Acquisitions

    Get PDF
    Receiver arrays with a large number of coil elements are becoming progressively available because of their increased signal-to-noise ratio (SNR) and enhanced parallel imaging performance. However, longer reconstruction time and intensive computational cost have become significant concerns as the number of channels increases, especially in some iterative reconstructions. Coil compression can effectively solve this problem by linearly combining the raw data from multiple coils into fewer virtual coils. In this work, geometric-decomposition coil compression (GCC) is applied to radial sampling (both linear-angle and golden-angle patterns are discussed) for better compression. GCC, which is different from directly compressing in k-space, is performed separately in each spatial location along the fully sampled directions, then followed by an additional alignment step to guarantee the smoothness of the virtual coil sensitivities. Both numerical simulation data and in vivo data were tested. Experimental results demonstrated that the GCC algorithm can achieve higher SNR and lower normalized root mean squared error values than the conventional principal component analysis approach in radial acquisitions

    Accelerating cardiovascular MRI

    Get PDF

    Fast Fiber Orientation Estimation in Diffusion MRI from kq-Space Sampling and Anatomical Priors

    Full text link
    High spatio-angular resolution diffusion MRI (dMRI) has been shown to provide accurate identification of complex fiber configurations, albeit at the cost of long acquisition times. We propose a method to recover intra-voxel fiber configurations at high spatio-angular resolution relying on a kq-space under-sampling scheme to enable accelerated acquisitions. The inverse problem for reconstruction of the fiber orientation distribution (FOD) is regularized by a structured sparsity prior promoting simultaneously voxelwise sparsity and spatial smoothness of fiber orientation. Prior knowledge of the spatial distribution of white matter, gray matter and cerebrospinal fluid is also assumed. A minimization problem is formulated and solved via a forward-backward convex optimization algorithmic structure. Simulations and real data analysis suggest that accurate FOD mapping can be achieved from severe kq-space under-sampling regimes, potentially enabling high spatio-angular dMRI in the clinical setting.Comment: 10 pages, 5 figures, Supplementary Material
    corecore