201 research outputs found

    UHF-Dielectrophoresis Crossover Frequency as a New Marker for Discrimination of Glioblastoma Undifferentiated Cells

    Get PDF

    Microfluidic Devices Fabrication for Bioelectrokinetic System Applications

    Get PDF
    The research and development of microfluidic technologies has increased tremendously over the past twenty years. The technology allows designers to create small, portable, robust, low cost and easy-to-use diagnostic instruments that offer high levels of capability and versatility. Microfluidic systems will decrease reagent consumption and reduce cost per analysis. It also reduces analysis time and provides better controllable process parameters in chemical reactions

    Dielectrophoresis of micro/nano particles using curved microelectrodes

    Full text link
    Dielectrophoresis, the induced motion of polarisable particles in non-homogenous electric field, has been proven as a versatile mechanism to transport, immobilise, sort and characterise micro/nano scale particle in microfluidic platforms. The performance of dielectrophoretic (DEP) systems depend on two parameters: the configuration of microelectrodes designed to produce the DEP force and the operating strategies devised to employ this force in such processes. This work summarises the unique features of curved microelectrodes for the DEP manipulation of target particles in microfluidic systems. The curved microelectrodes demonstrate exceptional capabilities including (i) creating strong electric fields over a large portion of their structure, (ii) minimising electro-thermal vortices and undesired disturbances at their tips, (iii) covering the entire width of the microchannel influencing all passing particles, and (iv) providing a large trapping area at their entrance region, as evidenced by extensive numerical and experimental analyses. These microelectrodes have been successfully applied for a variety of engineering and biomedical applications including (i) sorting and trapping model polystyrene particles based on their dimensions, (ii) patterning carbon nanotubes to trap low-conductive particles, (iii) sorting live and dead cells based on their dielectric properties, (iv) real-time analysis of drug-induced cell death, and (v) interfacing tumour cells with environmental scanning electron microscopy to study their morphological properties. The DEP systems based on curved microelectrodes have a great potential to be integrated with the future lab-on-a-chip systems.<br /

    Parallel manipulation of individual magnetic microbeads for lab-on-a-chip applications

    Get PDF
    Many scientists and engineers are turning to lab-on-a-chip systems for cheaper and high throughput analysis of chemical reactions and biomolecular interactions. In this work, we developed several lab-on-a-chip modules based on novel manipulations of individual microbeads inside microchannels. The first manipulation method employs arrays of soft ferromagnetic patterns fabricated inside a microfluidic channel and subjected to an external rotating magnetic field. We demonstrated that the system can be used to assemble individual beads (1-3µm) from a flow of suspended beads into a regular array on the chip, hence improving the integrated electrochemical detection of biomolecules bound to the bead surface. In addition, the microbeads can follow the external magnet rotating at very high speeds and simultaneously orbit around individual soft magnets on the chip. We employed this manipulation mode for efficient sample mixing in continuous microflow. Furthermore, we discovered a simple but effective way of transporting the microbeads on-chip in the rotating field. Selective transport of microbeads with different size was also realized, providing a platform for effective sample separation on a chip. The second manipulation method integrates magnetic and dielectrophoretic manipulations of the same microbeads. The device combines tapered conducting wires and fingered electrodes to generate desirable magnetic and electric fields, respectively. By externally programming the magnetic attraction and dielectrophoretic repulsion forces, out-of-plane oscillation of the microbeads across the channel height was realized. Furthermore, we demonstrated the tweezing of microbeads in liquid with high spatial resolutions by fine-tuning the net force from magnetic attraction and dielectrophoretic repulsion of the beads. The high-resolution control of the out-of-plane motion of the microbeads has led to the invention of massively parallel biomolecular tweezers.Ph.D.Committee Chair: Hesketh, Peter; Committee Member: Allen, Mark; Committee Member: Degertekin, Levent; Committee Member: Lu, Hang; Committee Member: Yoda, Minam

    Cell Manipulations with Dielectrophoresis

    Get PDF
    Biological sample analysis is a costly and time-consuming process. It involves highly trained technicians operating large and expensive instruments in a temperature and dust controlled environment. In the world of rising healthcare cost, the drive towards a more cost-effective solution calls for a point-of-care device that performs accurate analyses of human blood samples. To achieve this goal, today's bulky laboratory instruments need to be scaled down and integrated on a single microchip of only a few square centimeters or millimeters in size. Dielectrophoresis (DEP), a phenomenon where small particles such as human blood cells are manipulated by non-uniform electric fields, stands to feature prominently in the point-of-care device. An original device that enhances DEP effect through novel geometry of the electrodes is presented. When activated with two inverting sinusoidal waveforms, the novel-shaped electrodes generate horizontal bands of increasing electric fields on the surface of the microchip. With these bands of electric fields, particles can be manipulated to form a straight horizontal line at a predictable location. Experimental results showing the collection, separation, and transportation of mammalian cells are presented. A strategy for simultaneous processing of two or more types of particles is also demonstrated. With capabilities for an accurate position control and an increased throughput by parallel processing, the novel microchip device delivers substantial improvements over the existing DEP designs. The research presented here explores the effects of novel electrode geometries in cell manipulations and contributes to the overall progress of an automated blood analysis system

    Microscopic Particle Manipulation via Optoelectronic Devices

    Get PDF
    The optoelectronic tweezers (or optically induced dielectrophoresis (DEP)) have showed the ability to parallelly position a large number of colloidal microparticles without any template. The microparticles can be trapped and driven by the dielectrophoretic forces induced by the optical micropatterns in OET devices. In this chapter, the design and fabrication of flat optoelectronic devices (FOD) and hybrid optoelectronic device (HOD) are described. In the typical FOD, the manipulation modes including filtering, transporting, concentrating and focusing controlling regimes are experimentally demonstrated and analyzed. The controllable rotation of self-assembled microparticle chains in FOD has also been investigated, and a method incorporating the optically induced electrorotation (OER) and AC electroosmotic (ACEO) effects is numerically and experimentally implemented for manipulating microparticle chains. Based on the above research of FOD, a hybrid DEP microdevice HOD is conceptually and experimentally proposed. The HOD integrates with metallic microelectrode layer and the underneath photoconductive layer with projected optical virtual electrodes. FOD and HOD hybrid device enables the active driving, large-scale patterning and local position adjustment of microparticles. These techniques make up the shortcoming of low flexibility of traditional metallic microelectrodes and integrate the merits of both the metal electrode-induced and microimage-induced DEP techniques

    Dielectric measurement of cell death

    Get PDF

    Basic Study Of Micromachined Dep (dielectrophoretic) Manipulator

    Get PDF
    The capability of manipulating microparticle in small volumes is fundamental to many biological and medical applications, including separation and detection of cells. The development of microtools for effective sample handling and separation in such volumes is still a challenge. DEP (dielectrophoresis) is one of the most widely used methods in handling the microparticles. In this thesis we show that forces generated by nonuniform electric field (DEP) can be used for trapping and separating the microparticles (latex beads). This work further explores the DEP force based on different electrode geometries and medium conductivity. A micromanipulator for latex bead separation was designed, fabricated and characterized. For the development of DEP manipulator, the fabrication and packaging of microfluidic structure with the microelectrode is crucial for reliable analysis. A combination of SU-8 photoresist and polydimethylsiloxane polymer was used for this purpose. Besides, the DEP manipulator, preliminary study on a Coulter counter was conducted. The Coulter counter works on the principle of resistive pulse sensing. This counter is used for counting the beads as they pass through the microfluidic channel. Its possible integration with the manipulator was also explored

    Micro- and Nanofluidics for Bionanoparticle Analysis

    Get PDF
    Bionanoparticles such as microorganisms and exosomes are recoganized as important targets for clinical applications, food safety, and environmental monitoring. Other nanoscale biological particles, includeing liposomes, micelles, and functionalized polymeric particles are widely used in nanomedicines. The recent deveopment of microfluidic and nanofluidic technologies has enabled the separation and anslysis of these species in a lab-on-a-chip platform, while there are still many challenges to address before these analytical tools can be adopted in practice. For example, the complex matrices within which these species reside in create a high background for their detection. Their small dimension and often low concentration demand creative strategies to amplify the sensing signal and enhance the detection speed. This Special Issue aims to recruit recent discoveries and developments of micro- and nanofluidic strategies for the processing and analysis of biological nanoparticles. The collection of papers will hopefully bring out more innovative ideas and fundamental insights to overcome the hurdles faced in the separation and detection of bionanoparticles
    corecore