14,845 research outputs found
Physics-based passivity-preserving parameterized model order reduction for PEEC circuit analysis
The decrease of integrated circuit feature size and the increase of operating frequencies require 3-D electromagnetic methods, such as the partial element equivalent circuit (PEEC) method, for the analysis and design of high-speed circuits. Very large systems of equations are often produced by 3-D electromagnetic methods, and model order reduction (MOR) methods have proven to be very effective in combating such high complexity. During the circuit synthesis of large-scale digital or analog applications, it is important to predict the response of the circuit under study as a function of design parameters such as geometrical and substrate features. Traditional MOR techniques perform order reduction only with respect to frequency, and therefore the computation of a new electromagnetic model and the corresponding reduced model are needed each time a design parameter is modified, reducing the CPU efficiency. Parameterized model order reduction (PMOR) methods become necessary to reduce large systems of equations with respect to frequency and other design parameters of the circuit, such as geometrical layout or substrate characteristics. We propose a novel PMOR technique applicable to PEEC analysis which is based on a parameterization process of matrices generated by the PEEC method and the projection subspace generated by a passivity-preserving MOR method. The proposed PMOR technique guarantees overall stability and passivity of parameterized reduced order models over a user-defined range of design parameter values. Pertinent numerical examples validate the proposed PMOR approach
Data-driven modeling of the olfactory neural codes and their dynamics in the insect antennal lobe
Recordings from neurons in the insects' olfactory primary processing center,
the antennal lobe (AL), reveal that the AL is able to process the input from
chemical receptors into distinct neural activity patterns, called olfactory
neural codes. These exciting results show the importance of neural codes and
their relation to perception. The next challenge is to \emph{model the
dynamics} of neural codes. In our study, we perform multichannel recordings
from the projection neurons in the AL driven by different odorants. We then
derive a neural network from the electrophysiological data. The network
consists of lateral-inhibitory neurons and excitatory neurons, and is capable
of producing unique olfactory neural codes for the tested odorants.
Specifically, we (i) design a projection, an odor space, for the neural
recording from the AL, which discriminates between distinct odorants
trajectories (ii) characterize scent recognition, i.e., decision-making based
on olfactory signals and (iii) infer the wiring of the neural circuit, the
connectome of the AL. We show that the constructed model is consistent with
biological observations, such as contrast enhancement and robustness to noise.
The study answers a key biological question in identifying how lateral
inhibitory neurons can be wired to excitatory neurons to permit robust activity
patterns
Noiseless nonreciprocity in a parametric active device
Nonreciprocal devices such as circulators and isolators belong to an
important class of microwave components employed in applications like the
measurement of mesoscopic circuits at cryogenic temperatures. The measurement
protocols usually involve an amplification chain which relies on circulators to
separate input and output channels and to suppress backaction from different
stages on the sample under test. In these devices the usual reciprocal symmetry
of circuits is broken by the phenomenon of Faraday rotation based on magnetic
materials and fields. However, magnets are averse to on-chip integration, and
magnetic fields are deleterious to delicate superconducting devices. Here we
present a new proposal combining two stages of parametric modulation emulating
the action of a circulator. It is devoid of magnetic components and suitable
for on-chip integration. As the design is free of any dissipative elements and
based on reversible operation, the device operates noiselessly, giving it an
important advantage over other nonreciprocal active devices for quantum
information processing applications.Comment: 17 pages, 4 figures + 12 pages Supplementary Informatio
A Scanning laser-velocimeter technique for measuring two-dimensional wake-vortex velocity distributions
A rapid scanning two dimensional laser velocimeter (LV) has been used to measure simultaneously the vortex vertical and axial velocity distributions in the Langley Vortex Research Facility. This system utilized a two dimensional Bragg cell for removing flow direction ambiguity by translating the optical frequency for each velocity component, which was separated by band-pass filters. A rotational scan mechanism provided an incremental rapid scan to compensate for the large displacement of the vortex with time. The data were processed with a digital counter and an on-line minicomputer. Vaporized kerosene (0.5 micron to 5 micron particle sizes) was used for flow visualization and LV scattering centers. The overall measured mean-velocity uncertainity is less than 2 percent. These measurements were obtained from ensemble averaging of individual realizations
An LDA (Laser-Doppler Anemometry) investigation of three-dimensional normal shock wave boundary-layer interactions
Nonintrusive measurements were made of a normal shock wave/boundary layer interaction. Two dimensional measurements were made throughout the interaction region while 3-D measurements were made in the vicinity of the shock wave. The measurements were made in the corner of the test section of a continuous supersonic wind tunnel in which a normal shock wave had been stabilized. Laser Doppler Anemometry, surface pressure measurement and flow visualization techniques were employed for two freestream Mach number test cases: 1.6 and 1.3. The former contained separated flow regions and a system of shock waves. The latter was found to be far less complicated. The results define the flow field structure in detail for each case
Recommended from our members
Sample preparation for point of care molecular diagnostics of STIs
This paper was presented at the 4th Micro and Nano Flows Conference (MNF2014), which was held at University College, London, UK. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute, ASME Press, LCN London Centre for Nanotechnology, UCL University College London, UCL Engineering, the International NanoScience Community, www.nanopaprika.eu.Brunel DoCLab is part of the esti2 consortium developing electronic self-testing instruments for sexually transmitted infections using nucleic acid amplification testing (NAAT). A proprietary sample collection device has been designed to integrate directly with a microfluidic cartridge. Cell lysis was conducted using a chemical method and nucleic acid purification was done on an activated cellulose membrane. The microfluidic device incorporates passive mixing of the lysis-binding buffers and sample. Preliminary results have shown extraction efficiencies for this new membrane of 69% and 57% compared to the commercial Qiagen extraction method of 85% and 59.4% for 0.1ng/μL and 100ng/μL salmon sperm DNA spiked in phosphate buffered solution. Preliminary extraction experiments in the passive mixer cartridges with lysis and nucleic acid purification showed extraction efficiency around 80% of the commercial Qiagen kit. Isothermal amplification was conducted using thermophillic helicase dependant amplification. A low cost benchtop real-time isothermal amplification platform has been developed capable of running six amplifications simultaneously. Work to integrate sample collection, nucleic acid extraction and isothermal amplification is currently underway
- …