158 research outputs found

    Doctor of Philosophy

    Get PDF
    dissertationMore than a century ago, in his labs in Colorado Springs and New York, Nikola Tesla started experimenting with wireless power transfer (WPT). His ideas were ahead of his time, but they fell into obscurity shortly after his death. Nowadays, WPT is no longer thought of as science fiction: neural prostheses, wearables, cellphones, and even electric vehicles can be powered through WPT. In its most common implementation, WPT leverages the magnetic coupling between resonant transmitter and receiver coils to exchange energy. Considerable work is devoted to the design and optimization of WPT antennas; efficiently transmitting the required amount of power can only be accomplished when the coil coupling is in the right range. In this work, we explore the use of spatial filters in WPT systems. Spatial filters are capable of controlling the harmonic content of an incident wave: subwavelength focal spots, perfect lensing, and diffractionless beams are some of their uses. In the first part of this dissertation, the focus is on the analysis and design of a compact negative permeability metamaterial slab. Compared to other works in the literature, this slab is an extremely small fraction of the wavelength, and works at a low operating frequency. Analysis and experimental validation demonstrate that the resulting metamaterial sample can be used in a 2-coil WPT system to achieve large range and efficiency enhancements. In the second part of this dissertation, the analysis and implementation of holographic screens is presented. A method to reduce the fabrication complexity of the desired holographic screen while maintaining the fidelity of the prescribed field distribution is presented. We demonstrate our method through the analysis, design, and experimental validation of a nondiffractive beam launcher with a Bessel field distribution. Finally, we utilize the analysis and methods presented in this work to design an antenna capable of prescribing a uniform field distribution. Because of this property, this WPT antenna is capable of transmitting near constant power with near constant efficiency to the target receiver load, without the need of an adaptive compensation system

    Equivalent Circuit Modeling and Analysis of Metamaterial Based Wireless Power Transfer

    Full text link
    In this study, an equivalent circuit model is presented to emulate the behavior of a metamaterial-based wireless power transfer system. For this purpose, the electromagnetic field simulation of the proposed system is conducted in ANSYS high frequency structure simulator. In addition, a numerical analysis of the proposed structure is explored to evaluate its transfer characteristics. The power transfer efficiency of the proposed structure is represented by the transmission scattering parameter. While some methods, including interference theory and effective medium theory have been exploited to explain the physics mechanism of MM-based WPT systems, some of the reactive parameters and the basic physical interpretation have not been clearly expounded. In contrast to existing theoretical model, the proposed approach focuses on the effect of the system parameters and transfer coils on the system transfer characteristics and its effectiveness in analyzing complex circuit. Numerical solution of the system transfer characteristics, including the scattering parameter and power transfer efficiency is conducted in Matlab. The calculation results based on numerical estimation validates the full wave electromagnetic simulation results, effectively verifying the accuracy of the analytical model.Comment: 12 figures, 7 pages, IEEE Electromagnetic Compatibility Conferenc

    Doctor of Philosophy

    Get PDF
    dissertationMagnetic fields are permeable to the biological tissues and can induce electric field in the conductive structures. Some medical devices take advantage of this ability to transfer energy from the source to the receiving site without direct contact. Prosthetic devices such as retinal implants use time-varying magnetic field to achieve wireless power transfer to the implanted magnetic coil. However, devices such as magnetic stimulators use the induction principle to create an electric field at the stimulation site. Efficiency of these devices is primarily dependent on the design of the magnetic coils. Therefore, in this work, we designed and validated efficient magnetic coils for wireless power transfer to implanted devices and magnetic stimulation of the peripheral nerves. Typical wireless power transfer (WPT) systems uses two-coil based design to achieve contactless power transfer to the implanted electronics. These systems achieve low power transfer efficiency (< 30%) and frequency bandwidth. Moreover, efficient wireless system requires high coupling and load variation tolerance during device operation. To design an electromagnetic safe WPT system, the power absorbed by the tissue and radiated field due to the proximal magnetic coils needs to be minimized. In this work, we proposed a multi-coil power transfer system which solves some of the current challenges. The proposed multi-coil WPT system achieves more than twice the power transfer efficiency, controllable voltage gain, wider frequency bandwidth, higher tolerance to coupling and load variations, lower absorbed power in the tissue and lower radiated field from the magnetic coil than a comparable two-coil system. In this work, we have developed analytic models of the multi-coil WPT system and validated the accuracy of the solutions using experiments. Magnetic coils play an important role in controlling the distribution of induced electric field inside the nerve during magnetic stimulation. In the past, homogeneous models were used to estimate the field profile inside conductive tissue due to the time varying current in the magnetic coil. Moreover, the effect of the surrounding media and stimulation mechanisms was understudied, which limits the optimization accuracy of the magnetic coils. In this work, we developed anatomically correct tissue models to study the effect of tissue heterogeneity and the surrounding media on the induced electric field. We also developed an optimization algorithm for designing energy efficient cm-size magnetic coils, that were then used for ex-vivo magnetic stimulation of the frog's sciatic nerve

    Wireless Power Transfer For Biomedical Applications

    Get PDF
    In this research wireless power transfer using near-field inductive coupling is studied and investigated. The focus is on delivering power to implantable biomedical devices. The objective of this research is to optimize the size and performance of the implanted wireless biomedical sensors by: (1) proposing a hybrid multiband communication system for implantable devices that combines wireless communication link and power transfer, and (2) optimizing the wireless power delivery system. Wireless data and power links are necessary for many implanted biomedical devices such as biosensors, neural recording and stimulation devices, and drug delivery and monitoring systems. The contributions from this research work are summarized as follows: 1. Development of a combination of inductive power transfer and antenna system. 2. Design and optimization of novel microstrip antenna that may resonate at different ultra-high frequency bands including 415 MHz, 905 MHz, and 1300MHz. These antennas may be used to transfer power through radiation or send/receive data. 3. Design of high-frequency coil (13.56 MHz) to transfer power and optimization of the parameters for best efficiency. 4. Study of the performance of the hybrid antenna/coil system at various depths inside a body tissue model. 5. Minimizing the coupling effect between the coil and the antenna through addressed by optimizing their dimensions. 6. Study of the effects of lateral and angular misalignment on a hybrid compact system consisting of coil and antenna, as well as design and optimize the coilâs geometry which can provide maximum power efficiency under misalignment conditions. 7. Address the effects of receiver bending of a hybrid power transfer and communication system on the communication link budget and the transmitted power. 8. Study the wireless power transfer safety and security systems

    A Novel Power-Efficient Wireless Multi-channel Recording System for the Telemonitoring of Electroencephalography (EEG)

    Get PDF
    This research introduces the development of a novel EEG recording system that is modular, batteryless, and wireless (untethered) with the supporting theoretical foundation in wireless communications and related design elements and circuitry. Its modular construct overcomes the EEG scaling problem and makes it easier for reconfiguring the hardware design in terms of the number and placement of electrodes and type of standard EEG system contemplated for use. In this development, portability, lightweight, and applicability to other clinical applications that rely on EEG data are sought. Due to printer tolerance, the 3D printed cap consists of 61 electrode placements. This recording capacity can however extend from 21 (as in the international 10-20 systems) up to 61 EEG channels at sample rates ranging from 250 to 1000 Hz and the transfer of the raw EEG signal using a standard allocated frequency as a data carrier. The main objectives of this dissertation are to (1) eliminate the need for heavy mounted batteries, (2) overcome the requirement for bulky power systems, and (3) avoid the use of data cables to untether the EEG system from the subject for a more practical and less restrictive setting. Unpredictability and temporal variations of the EEG input make developing a battery-free and cable-free EEG reading device challenging. Professional high-quality and high-resolution analog front ends are required to capture non-stationary EEG signals at microvolt levels. The primary components of the proposed setup are the wireless power transmission unit, which consists of a power amplifier, highly efficient resonant-inductive link, rectification, regulation, and power management units, as well as the analog front end, which consists of an analog to digital converter, pre-amplification unit, filtering unit, host microprocessor, and the wireless communication unit. These must all be compatible with the rest of the system and must use the least amount of power possible while minimizing the presence of noise and the attenuation of the recorded signal A highly efficient resonant-inductive coupling link is developed to decrease power transmission dissipation. Magnetized materials were utilized to steer electromagnetic flux and decrease route and medium loss while transmitting the required energy with low dissipation. Signal pre-amplification is handled by the front-end active electrodes. Standard bio-amplifier design approaches are combined to accomplish this purpose, and a thorough investigation of the optimum ADC, microcontroller, and transceiver units has been carried out. We can minimize overall system weight and power consumption by employing battery-less and cable-free EEG readout system designs, consequently giving patients more comfort and freedom of movement. Similarly, the solutions are designed to match the performance of medical-grade equipment. The captured electrical impulses using the proposed setup can be stored for various uses, including classification, prediction, 3D source localization, and for monitoring and diagnosing different brain disorders. All the proposed designs and supporting mathematical derivations were validated through empirical and software-simulated experiments. Many of the proposed designs, including the 3D head cap, the wireless power transmission unit, and the pre-amplification unit, are already fabricated, and the schematic circuits and simulation results were based on Spice, Altium, and high-frequency structure simulator (HFSS) software. The fully integrated head cap to be fabricated would require embedding the active electrodes into the 3D headset and applying current technological advances to miniaturize some of the design elements developed in this dissertation

    A design technique for geometric optimisation of resonant coil sizes in low to mid frequency inductive power transmission systems.

    Get PDF
    Wireless power transfer (WPT) is a well-established method of energising electrically-powered devices. Among the different available WPT techniques, Resonant Inductive Power Transfer (RIPT) has been adapted for use in a wide range of applications. The primary reason is the relatively higher Power Transfer Efficiency (PTE) that RIPT can provide. RIPT systems operate on the principle of magnetic resonance coupling between a Transmitter (Tx) and a Receiver (Rx) coil. Maximising the PTE is a key driver for improving the performance of RIPT systems. In a RIPT link the PTE is influenced by three factors: (i) inductive linkage between the Tx and Rx, (ii) terminating circuitry of Tx and Rx sides and (iii) the Tx/Rx coil's geometrical size. In considering these impacting factors, different techniques to improve PTE have been extensively presented in the literature and are comprehensively reviewed in this thesis. The research work undertaken focuses on the geometrical optimisation of Tx/Rx coils to help maximise PTE in RIPT systems for operation over low- and mid-frequency bands (i.e. between few kHz to several MHz). Conventional methods for maximising PTE require defining various design parameters (i.e. figure-of-merits), which assist in finding the optimum Air-Cored Coil (ACC) geometry. However, traditional techniques for working with Figure-of-Merit (FoM) parameters are very time-consuming and process-demanding. In this thesis, the number of required FoMs have been reduced to one and incorporated into a process that will accelerate production of the optimum geometry design. A unique FoM parameter (i.e. Pscf) is developed by consolidating the PTE's impacting factors. Considering the RIPT application and its physical size constraints, a proper selection method for identifying the numerical value of Pscf is investigated. A novel iterative algorithm has been developed to assist in selection of the most favourable Pscf value, which provides the optimum ACC geometry. Theoretical design examples of two RIPT systems - operating at 10 kHz (low-frequency band) and 300 kHz (mid-frequency band) - are used to investigate the functionality of the ACC design approach, for which successful results are achieved. The novel iterative algorithm is also experimentally validated by developing four prototyped Tx/Rx ACC pairs, with real-world applications, which operate over low- and mid-frequency bands: 1:06 MHz, 100 kHz, 50 kHz, 15 kHz. For the designed ACC geometries, maximum PTEs of 85:63% at 1:06 MHz, 83:10% at 100 kHz, 72:85% at 50 kHz and 34:57% at 15 kHz are practically measured in bench top tests. The measured PTE values are in close correlation (within 14%) with the calculated PTEs at these frequency ranges, and thus validate the novel ACC design procedure. The RIPT system's maximum achievable PTE can be further increased by adding ferrite cores to the Tx/Rx ACC pair. In this thesis, an advanced iterative algorithm is also presented to support the design of geometrically optimised coil pairs employing ferrite cores. The advanced iterative algorithm is an extension of the initial work on optimising ACC geometries. Optimum Ferrite-Cored Coil (FCC) geometries, produced using the advanced iterative algorithm, for RIPT systems operating at 10 kHz and 300 kHz have been investigated. In comparing the FCC and ACC geometries designed for these frequencies, it is demonstrated that RIPT systems with ferrite cores reduce the ACC's geometrical size and additionally improve PTE. To validate the performance of the advanced FCC design algorithm over low- and mid-frequency bands, two RIPT systems are physically constructed for operation at 15 kHz (low-frequency) and 50 kHz (mid-frequency). For the prototyped RIPT systems, maximum PTEs of 45:16% at 50 kHz and 50:74% at 15 kHz are practically measured. The calculated and physically measured PTE values are within 2% difference; hence validating the advanced FCC design process

    Wireless Power Transfer Techniques for Implantable Medical Devices:A Review

    Get PDF
    Wireless power transfer (WPT) systems have become increasingly suitable solutions for the electrical powering of advanced multifunctional micro-electronic devices such as those found in current biomedical implants. The design and implementation of high power transfer efficiency WPT systems are, however, challenging. The size of the WPT system, the separation distance between the outside environment and location of the implanted medical device inside the body, the operating frequency and tissue safety due to power dissipation are key parameters to consider in the design of WPT systems. This article provides a systematic review of the wide range of WPT systems that have been investigated over the last two decades to improve overall system performance. The various strategies implemented to transfer wireless power in implantable medical devices (IMDs) were reviewed, which includes capacitive coupling, inductive coupling, magnetic resonance coupling and, more recently, acoustic and optical powering methods. The strengths and limitations of all these techniques are benchmarked against each other and particular emphasis is placed on comparing the implanted receiver size, the WPT distance, power transfer efficiency and tissue safety presented by the resulting systems. Necessary improvements and trends of each WPT techniques are also indicated per specific IMD

    Wide Band Embedded Slot Antennas for Biomedical, Harsh Environment, and Rescue Applications

    Get PDF
    For many designers, embedded antenna design is a very challenging task when designing embedded systems. Designing Antennas to given set of specifications is typically tailored to efficiently radiate the energy to free space with a certain radiation pattern and operating frequency range, but its design becomes even harder when embedded in multi-layer environment, being conformal to a surface, or matched to a wide range of loads (environments). In an effort to clarify the design process, we took a closer look at the key considerations for designing an embedded antenna. The design could be geared towards wireless/mobile platforms, wearable antennas, or body area network. Our group at UT has been involved in developing portable and embedded systems for multi-band operation for cell phones or laptops. The design of these antennas addressed single band/narrowband to multiband/wideband operation and provided over 7 bands within the cellular bands (850 MHz to 2 GHz). Typically the challenge is: many applications require ultra wide band operation, or operate at low frequency. Low frequency operation is very challenging if size is a constraint, and there is a need for demonstrating positive antenna gain
    • …
    corecore