    Controller Synthesis of Multi-Axial Robotic System Used for Wearable Devices

    Get PDF
    Wearable devices are commonly used in different fields to help improving performance of movements for different groups of users. The long-term goal of this study is to develop a low-cost assistive robotic device that allows patients to perform rehabilitation activities independently and reproduces natural movement to help stroke patients and elderly adults in their daily activities while moving their arms. In the past few decades, various types of wearable robotic devices have been developed to assist different physical movements. Among different types of actuators, the twisted-string actuation system is one of those that has advantages of light-weight, low cost, and great portability. In this study, a dual twisted-string actuator is used to drive the joints of the prototype assistive robotic device. To compensate the asynchronous movement caused by nonlinear factors, a hybrid controller that combines fuzzy logic rules and linear PID control algorithm was adopted to compensate for both tracking and synchronization of the two actuators.;In order to validate the performance of proposed controllers, the robotic device was driven by an xPC Target machine with additional embedded controllers for different data acquisition tasks. The controllers were fine tuned to eliminate the inaccuracy of tracking and synchronization caused by disturbance and asynchronous movements of both actuators. As a result, the synthesized controller can provide a high precision when tracking simple actual human movements

    Prevalence of haptic feedback in robot-mediated surgery : a systematic review of literature

    Get PDF
    © 2017 Springer-Verlag. This is a post-peer-review, pre-copyedit version of an article published in Journal of Robotic Surgery. The final authenticated version is available online at: https://doi.org/10.1007/s11701-017-0763-4With the successful uptake and inclusion of robotic systems in minimally invasive surgery and with the increasing application of robotic surgery (RS) in numerous surgical specialities worldwide, there is now a need to develop and enhance the technology further. One such improvement is the implementation and amalgamation of haptic feedback technology into RS which will permit the operating surgeon on the console to receive haptic information on the type of tissue being operated on. The main advantage of using this is to allow the operating surgeon to feel and control the amount of force applied to different tissues during surgery thus minimising the risk of tissue damage due to both the direct and indirect effects of excessive tissue force or tension being applied during RS. We performed a two-rater systematic review to identify the latest developments and potential avenues of improving technology in the application and implementation of haptic feedback technology to the operating surgeon on the console during RS. This review provides a summary of technological enhancements in RS, considering different stages of work, from proof of concept to cadaver tissue testing, surgery in animals, and finally real implementation in surgical practice. We identify that at the time of this review, while there is a unanimous agreement regarding need for haptic and tactile feedback, there are no solutions or products available that address this need. There is a scope and need for new developments in haptic augmentation for robot-mediated surgery with the aim of improving patient care and robotic surgical technology further.Peer reviewe

    A survey on bio-signal analysis for human-robot interaction

    Get PDF
    The use of bio-signals analysis in human-robot interaction is rapidly increasing. There is an urgent demand for it in various applications, including health care, rehabilitation, research, technology, and manufacturing. Despite several state-of-the-art bio-signals analyses in human-robot interaction (HRI) research, it is unclear which one is the best. In this paper, the following topics will be discussed: robotic systems should be given priority in the rehabilitation and aid of amputees and disabled people; second, domains of feature extraction approaches now in use, which are divided into three main sections (time, frequency, and time-frequency). The various domains will be discussed, then a discussion of each domain's benefits and drawbacks, and finally, a recommendation for a new strategy for robotic systems

    Modeling and Dynamic performance of Energy Storage -Rotary Series Elastic Actuator for Lumbar Support Exoskeleton

    Get PDF
    The assistive exoskeletons are rapidly being developed to collaborate with humans, and the demand for the safety of human-robot interaction has become more crucial. Series elastic actuators (SEAs) have recently been developed in various fields for a variety of possible advantages, such as providing a safe human-robot interaction, reducing the impacts’ effects, and increasing energy efficiency. However, achieving the good dynamic performances of SEAs is still challenging, especially fulfilling the high bandwidth with good compliance. In this rapidly growing research field, the actuation system involving the storage device combined with the rotary series elastic actuator (ES-RSEA) is being investigated to exploit the biomechanical energy while maintaining compliance features. In this article, the modeling and control design of the energy storage rotary series elastic actuator (ES-RSEA) for the lumbar support exoskeleton is proposed, and its dynamic performances are analyzed. The ES-RSEA was designed based on storing the kinetic energy during the lifting tasks and generating assistive torque while maintaining excellent compliant characteristics. The dynamic performances and characteristics of ES-RSEA are presented in terms of force sensitivity, level of compliance, transmission ratio, and bandwidth. Simulation studies indicate that the actuator can provide excellent dynamic performance through its high bandwidth (12.44 Hz) and high force sensitivity. At the same time, it shows excellent compliance and good torque transmissibility in the low-frequency range. A PID controller can achieve high torque tracking performance and good dynamic response with a root-mean-square (RMS) error of 0.1 N.m. This article demonstrates the excellent performance and characteristics of ES-RSEA to guarantee compliance and high response to prevent injury of undesired human movements

    Force control of lightweight series elastic systems using enhanced disturbance observers

    Get PDF
    This paper analyzes the control challenges associated to lightweight series elastic systems in force control applications, showing that a low end-point inertia can lead to high sensitivity to environment uncertainties. Where mainstream force control methods fail, this paper proposes a control methodology to enhance the performance robustness of existing disturbance observers (DOBs). The approach is validated experimentally and successfully compared to basic control solutions and state of the art DOB approaches
    corecore