386 research outputs found

    Development of a synthetic phantom for the selection of optimal scanning parameters in CAD-CT colonography

    Get PDF
    The aim of this paper is to present the development of a synthetic phantom that can be used for the selection of optimal scanning parameters in computed tomography (CT) colonography. In this paper we attempt to evaluate the influence of the main scanning parameters including slice thickness, reconstruction interval, field of view, table speed and radiation dose on the overall performance of a computer aided detection (CAD)–CTC system. From these parameters the radiation dose received a special attention, as the major problem associated with CTC is the patient exposure to significant levels of ionising radiation. To examine the influence of the scanning parameters we performed 51 CT scans where the spread of scanning parameters was divided into seven different protocols. A large number of experimental tests were performed and the results analysed. The results show that automatic polyp detection is feasible even in cases when the CAD–CTC system was applied to low dose CT data acquired with the following protocol: 13 mAs/rotation with collimation of 1.5 mm × 16 mm, slice thickness of 3.0 mm, reconstruction interval of 1.5 mm, table speed of 30 mm per rotation. The CT phantom data acquired using this protocol was analysed by an automated CAD–CTC system and the experimental results indicate that our system identified all clinically significant polyps (i.e. larger than 5 mm)

    Computer-assisted polyp matching between optical colonoscopy and CT colonography: a phantom study

    Full text link
    Potentially precancerous polyps detected with CT colonography (CTC) need to be removed subsequently, using an optical colonoscope (OC). Due to large colonic deformations induced by the colonoscope, even very experienced colonoscopists find it difficult to pinpoint the exact location of the colonoscope tip in relation to polyps reported on CTC. This can cause unduly prolonged OC examinations that are stressful for the patient, colonoscopist and supporting staff. We developed a method, based on monocular 3D reconstruction from OC images, that automatically matches polyps observed in OC with polyps reported on prior CTC. A matching cost is computed, using rigid point-based registration between surface point clouds extracted from both modalities. A 3D printed and painted phantom of a 25 cm long transverse colon segment was used to validate the method on two medium sized polyps. Results indicate that the matching cost is smaller at the correct corresponding polyp between OC and CTC: the value is 3.9 times higher at the incorrect polyp, comparing the correct match between polyps to the incorrect match. Furthermore, we evaluate the matching of the reconstructed polyp from OC with other colonic endoluminal surface structures such as haustral folds and show that there is a minimum at the correct polyp from CTC. Automated matching between polyps observed at OC and prior CTC would facilitate the biopsy or removal of true-positive pathology or exclusion of false-positive CTC findings, and would reduce colonoscopy false-negative (missed) polyps. Ultimately, such a method might reduce healthcare costs, patient inconvenience and discomfort.Comment: This paper was presented at the SPIE Medical Imaging 2014 conferenc

    The use of 3D surface fitting for robust polyp detection and classification in CT colonography

    Get PDF
    In this paper we describe the development of a computationally efficient computer-aided detection (CAD) algorithm based on the evaluation of the surface morphology that is employed for the detection of colonic polyps in computed tomography (CT) colonography. Initial polyp candidate voxels were detected using the surface normal intersection values. These candidate voxels were clustered using the normal direction, convexity test, region growing and Gaussian distribution. The local colonic surface was classified as polyp or fold using a feature normalized nearest neighborhood classifier. The main merit of this paper is the methodology applied to select the robust features derived from the colon surface that have a high discriminative power for polyp/fold classification. The devised polyp detection scheme entails a low computational overhead (typically takes 2.20 min per dataset) and shows 100% sensitivity for phantom polyps greater than 5 mm. It also shows 100% sensitivity for real polyps larger than 10 mm and 91.67% sensitivity for polyps between 5 to 10 mm with an average of 4.5 false positives per dataset. The experimental data indicates that the proposed CAD polyp detection scheme outperforms other techniques that identify the polyps using features that sample the colon surface curvature especially when applied to low-dose datasets

    A fully automatic CAD-CTC system based on curvature analysis for standard and low-dose CT data

    Get PDF
    Computed tomography colonography (CTC) is a rapidly evolving noninvasive medical investigation that is viewed by radiologists as a potential screening technique for the detection of colorectal polyps. Due to the technical advances in CT system design, the volume of data required to be processed by radiologists has increased significantly, and as a consequence the manual analysis of this information has become an increasingly time consuming process whose results can be affected by inter- and intrauser variability. The aim of this paper is to detail the implementation of a fully integrated CAD-CTC system that is able to robustly identify the clinically significant polyps in the CT data. The CAD-CTC system described in this paper is a multistage implementation whose main system components are: 1) automatic colon segmentation; 2) candidate surface extraction; 3) feature extraction; and 4) classification. Our CAD-CTC system performs at 100% sensitivity for polyps larger than 10 mm, 92% sensitivity for polyps in the range 5 to 10 mm, and 57.14% sensitivity for polyps smaller than 5 mm with an average of 3.38 false positives per dataset. The developed system has been evaluated on synthetic and real patient CT data acquired with standard and low-dose radiation levels

    A novel technique for reducing false positive detections in CAD-CTC

    Get PDF
    Computed tomography colonoscopy (CTC) is an emerging alternative to conventional colonoscopy for colorectal cancer screening. A series of computer assisted diagnosis (CAD) techniques have been developed for use in CTC. Although high levels of accuracy for polyp detection have been reported, the problem of excessive false positive detections still warrants attention. We present a CAD-CTC technique that has been developed specifically to reduce the number of false positive detections without compromising polyp detection accuracy. The technique incorporates a novel intermediate stage that restructures initial polyp candidates so that they conform more closely to the shape of actual polyps. The restructuring process causes false positives to expand to include more false positive characteristics, whereas, actual polyps retain their original polyp-like characteristics. An evaluation of the documented technique demonstrated that it can be successfully applied to the majority of polyp candidates, and that its use can reduce the number of false positive detections by up to 57.8%

    Technological advances: what hope for colorectal cancer?

    Get PDF
    Introduction: Colorectal cancers rank third in all cancers. Mass screening has proven effectiveness by significantly reducing incidence and mortality. If optical colonoscopy is the reference exam, virtual colonoscopy is an alternative of choice. We evaluate its first-line position in screening, following technological progress. Methods: We used PubMed's electronic search data from 2010. Among the 100 most consulted articles, have been studied those in English-language and which looked at screening in the population at average risk aged between 50 and 75 years , asymptomatic and dealing with optical and virtual colonoscopy. Studies in the symptomatic, high-risk, or very high-risk population or for diagnostic purposes were excluded. Results: in the USA, studies confirm the trend towards a decrease in incidence and mortality by colorectal cancers, shifting from 56.7 per 100,000 and 23.6 deaths respectively in 1992 to 36.5 per 100,000 and 14 deaths in 2015, thanks to the means of screening including the endoscopy. Although optical colonoscopy is the standard exam, virtual colonoscopy, with a specificity of 90% and a sensitivity of 85%, is becoming more and more a first-line means of screening for colorectal cancers. Conclusion: Thus, first-line endoscopic screening has proved its effectiveness in reducing morbidity and mortality by this cancer. However, the virtual endoscopy chosen by the National Comprehensive Cancer Network as a means of screening will undoubtedly constitute a strategy for the future, particularly in developing countries

    Context-specific method for detection of soft-tissue lesions in non-cathartic low-dose dual-energy CT colonography

    Get PDF
    In computed tomographic colonography (CTC), orally administered fecal-tagging agents can be used to indicate residual feces and fluid that could otherwise hide or imitate lesions on CTC images of the colon. Although the use of fecal tagging improves the detection accuracy of CTC, it can introduce image artifacts that may cause lesions that are covered by fecal tagging to have a different visual appearance than those not covered by fecal tagging. This can distort the values of image-based computational features, thereby reducing the accuracy of computer-aided detection (CADe). We developed a context-specific method that performs the detection of lesions separately on lumen regions covered by air and on those covered by fecal tagging, thereby facilitating the optimization of detection parameters separately for these regions and their detected lesion candidates to improve the detection accuracy of CADe. For pilot evaluation, the method was integrated into a dual-energy CADe (DE-CADe) scheme and evaluated by use of leave-one-patient-out evaluation on 66 clinical non-cathartic low-dose dual-energy CTC (DE-CTC) cases that were acquired at a low effective radiation dose and reconstructed by use of iterative image reconstruction. There were 22 colonoscopy-confirmed lesions ≥6 mm in size in 21 patients. The DE-CADe scheme detected 96% of the lesions at a median of 6 FP detections per patient. These preliminary results indicate that the use of context-specific detection can yield high detection accuracy of CADe in non-cathartic low-dose DE-CTC examinations
    corecore