    Magneettikuvauksella ohjattu korkean intensiteetin kohdennettu ultraääniteknologia syöpätautien liitännäishoidoissa ja syöpälääkkeiden annostelussa

    Get PDF
    Ablative hyperthermia (more than 55 °C) has been used as a stand-alone treatment for accessible solid tumors not amenable to surgery, whereas mild hyperthermia (40-45 °C) has been shown effective as an adjuvant for both radiotherapy and chemotherapy. An optimal mild hyperthermia treatment is noninvasive and spatially accurate, with precise and homogeneous heating limited to the target region. High-intensity focused ultrasound (HIFU) can noninvasively heat solid tumors deep within the human body. Magnetic resonance imaging (MRI) is ideal for HIFU treatment planning and monitoring in real time due to its superior soft-tissue contrast, high spatial imaging resolution, and the ability to measure temperature changes. The combination of MRI and HIFU therapy is known as magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU). Low temperature-sensitive liposomes (LTSLs) release their drug cargo in response to heat (more than 40 °C) and may improve drug delivery to solid tumors when combined with mild hyperthermia. MR-HIFU provides a way to image and control content release from imageable low-temperature sensitive liposomes (iLTSLs). This ability may enable spatiotemporal control over drug delivery - a concept known as drug dose painting. The objectives of this dissertation work were to develop and implement a clinically relevant volumetric mild hyperthermia heating algorithm, to implement and characterize different sonication approaches (multiple foci vs. single focus), and to evaluate the ability to monitor and control heating in real time using MR-HIFU. In addition, the ability of MR-HIFU to induce the release of a clinical-grade cancer drug encapsulated in LTSLs was investigated, and the potential of MR-HIFU mediated mild hyperthermia for clinical translation as an image-guided drug delivery method was explored. Finally, drug and contrast agent release of iLTSLs as well as the ability of MR-HIFU to induce and monitor the content release were examined, and a computational model that simulates MR-HIFU tissue heating and drug delivery was validated. The combination of a multifoci sonication approach and the mild hyperthermia heating algorithm resulted in precise and homogeneous heating limited to the targeted region both in vitro and in vivo. Heating was more spatially confined compared to the use of single focus sonication method. The improvement in spatial control suggests that multifoci heating is a useful tool in MR-HIFU mediated mild hyperthermia applications for clinical oncology. Using the mild hyperthermia heating algorithm, LTSL + MR-HIFU resulted in significantly higher tumor drug concentrations compared to free drug and LTSL alone. This technique has potential for clinical translation as an image-guided drug delivery method. MR-HIFU also enabled real-time monitoring and control of iLTSL content release. Finally, computational models may allow quantitative in silico comparison of different MR-HIFU heating algorithms as well as facilitate therapy planning for this drug delivery technique.Ablatiivista hypertermiaa (yli 55 °C) on perinteisesti käytetty leikkauksiin soveltumattomien kasvainten hoitoon. Lievän hypertermian (40-45 °C) on sen sijaan todettu olevan tehokas liitännäishoito syöpätautien säde- ja lääkehoidoille. Suotuisa hypertermiahoito on kajoamatonta ja täsmällisesti kohdistettua. Lämmityksen tulisi lisäksi olla tarkkaa, tasalaatuista ja kohdealueeseen rajoittunutta. Korkean intensiteetin kohdennettu ultraääni (HIFU) -hoito mahdollistaa kasvainten kajoamattoman lämmityksen. Magneettikuvauksen (MK) etuina ovat erinomainen pehmytkudoskontrasti, korkea paikkaresoluutio ja kyky mitata lämpötilan muutoksia. Näin ollen MK soveltuu erinomaisesti HIFU -hoitojen suunnitteluun ja seurantaan. MK:n ja HIFU:n yhdistelmää kutsutaan magneettikuvauksella ohjatuksi korkean intensiteetin kohdennetuksi ultraääniteknologiaksi (MR-HIFU). Lämpötilaherkät liposomit ovat suunniteltuja vapauttamaan lääkeainesisältönsä hieman normaalia ruumiinlämpötilaa korkeammissa lämpötiloissa (yli 40 °C). Yhdessä lievän hypertermian kanssa tämänkaltaiset liposomit voivat mahdollistaa kohdistetun lääkeaineen vapauttamisen. Liposomien sisällön vapautumisen tarkkailu voi myös mahdollistaa tarkan lääkemäärän kohdistetun annostelun kasvaimessa. Väitöskirjatyössä kehitettiin kliinisesti merkittävä lämmitysalgoritmi lievän hypertermian aikaansaamiseksi, toteutettiin usean samanaikaisen kohteen sonikaatio (ultraäänialtistus) menetelmä sekä arvioitiin algoritmin ja menetelmän kykyä kontrolloida kudoksen lämpötilaa käyttäen kliinistä MR-HIFU laitetta. Lisäksi tutkittiin HIFU:n kykyä vapauttaa lääkeaine lämpötilaherkistä liposomeista, karakterisoitiin lääke- ja kontrastiaineen vapautuminen kuvannettavissa olevista lämpötilaherkistä liposomeista sekä tarkasteltiin MR-HIFU:lla aikaansaadun lievän hypertermian potentiaalia kohdentaa lääkeaineen vapautuminen kasvaimeen. Tässä työssä myös validoitiin laskennallinen malli, joka simuloi MR-HIFU:lla aikaansaatua lämmitystä ja siitä johtuvaa lääkeaineen vapautumista, sekä todennettiin MR-HIFU:n sopivuus lämpöablaatioon perustuvaan kohdun pehmytkudoskasvainten hoitomenelmään kliinisessä käytössä. Lievän hypertermian lämmitysalgoritmi yhdessä usean kohteen sonikaatiomenetelmän kanssa tuotti täsmällisen, tasalaatuisen sekä paikallisesti rajoitetun lämmityksen kohdealueessa. Usean kohteen sonikaatiomenetelmä voi siis olla hyödyllinen työkalu MR-HIFU:n lievän hypertermian syöpähoidon sovelluksissa. MR-HIFU yhdessä lämpötilaherkkien liposomien kanssa sai aikaan merkittävästi korkeamman kasvaimen lääkeainekonsentraation verrokkiryhmiin nähden, ja saattaa siten soveltua kliiniseen käyttöön kuvantamisavusteisena lääkehoitona. Liposomien sisällön (lääkeaine + MK-kontrastiaine) vapautumisen kuvannettavuus merkitsee, että MR-HIFU saattaa lisäksi mahdollistaa tarkan lääkeannoksen kohdistetun vapauttamisen

    Developmental delays and subcellular stress as downstream effects of sonoporation

    Get PDF
    Posters: no. 2Control ID: 1672434OBJECTIVES: The biological impact of sonoporation has often been overlooked. Here we seek to obtain insight into the cytotoxic impact of sonoporation by gaining new perspectives on anti-proliferative characteristics that may emerge within sonoporated cells. We particularly focused on investigating the cell-cycle progression kinetics of sonoporated cells and identifying organelles that may be stressed in the recovery process. METHODS: In line with recommendations on exposure hardware design, an immersion-based ultrasound platform has been developed. It delivers 1 MHz ultrasound pulses (100 cycles; 1 kHz PRF; 60 s total duration) with 0.45 MPa peak negative pressure to a cell chamber that housed HL-60 leukemia cells and lipid-shelled microbubbles at a 10:1 cell-tobubble ratio (for 1e6/ml cell density). Calcein was used to facilitate tracking of sonoporated cells with enhanced uptake of exogenous molecules. The developmental trend of sonoporated cells was quantitatively analyzed using BrdU/DNA flow cytometry that monitors the cell population’s DNA synthesis kinetics. This allowed us to measure the temporal progression of DNA synthesis of sonoporated cells. To investigate whether sonoporation would upset subcellular homeostasis, post-exposure cell samples were also assayed for various proteins using Western blot analysis. Analysis focus was placed on the endoplasmic reticulum (ER): an important organelle with multi-faceted role in cellular functioning. The post-exposure observation time spanned between 0-24 h. RESULTS: Despite maintaining viability, sonoporated cells were found to exhibit delays in cell-cycle progression. Specifically, their DNA synthesis time was lengthened substantially (for HL-60 cells: 8.7 h for control vs 13.4 h for the sonoporated group). This indicates that sonoporated cells were under stress: a phenomenon that is supported by our Western blot assays showing upregulation of ER-resident enzymes (PDI, Ero1), ER stress sensors (PERK, IRE1), and ER-triggered pro-apoptotic signals (CHOP, JNK). CONCLUSIONS: Sonoporation, whilst being able to facilitate internalization of exogenous molecules, may inadvertently elicit a cellular stress response. These findings seem to echo recent calls for reconsideration of efficiency issues in sonoporation-mediated drug delivery. Further efforts would be necessary to improve the efficiency of sonoporation-based biomedical applications where cell death is not desirable.postprin

    A study on the change in plasma membrane potential during sonoporation

    Get PDF
    Posters: no. 4Control ID: 1680329OBJECTIVES: There has been validated that the correlation of sonoporation with calcium transients is generated by ultrasound-mediated microbubbles activity. Besides calcium, other ionic flows are likely involved in sonoporation. Our hypothesis is the cell electrophysiological properties are related to the intracellular delivery by ultrasound and microbubbles. In this study, a real-time live cell imaging platform is used to determine whether plasma membrane potential change is related to the sonoporation process at the cellular level. METHODS: Hela cells were cultured in DMEM supplemented with 10% FBS in Opticell Chamber at 37 °C and 5% CO2, and reached 80% confluency before experiments. The Calcein Blue-AM, DiBAC4(3) loaded cells in the Opticell chamber filled with PI solution and Sonovue microbubbles were immerged in a water tank on a inverted fluorescence microscope. Pulsed ultrasound (1MHz freq., 20 cycles, 20Hz PRF, 0.2-0.5MPa PNP) was irradiated at the angle of 45° to the region of interest for 1s.The real-time fluorescence imaging for different probes was acquired by a cooled CCD camera every 20s for 10min. The time-lapse fluorescence images were quantitatively analyzed to evaluate the correlation of cell viability, intracellular delivery with plasma membrane potential change. RESULTS: Our preliminary data showed that the PI fluorescence, which indicated intracellular delivery, was immediately accumulated in cells adjacent to microbubbles after exposure, suggesting that their membranes were damaged by ultrasound-activated microbubbles. However, the fluorescence reached its highest level within 4 to 6 minutes and was unchanged thereafter, indicating the membrane was gradually repaired within this period. Furthermore, using DIBAC4(3), which detected the change in the cell membrane potential, we found that the loss of membrane potential might be associated with intracellular delivery, because the PI fluorescence accumulation was usually accompanied with the change in DIBAC4 (3) fluorescence. CONCLUSIONS: Our study suggests that there may be a linkage between the cell membrane potential change and intracellular delivery mediated by ultrasound and microbubbles. We also suggest that other ionic flows or ion channels may be involved in the cell membrane potential change in sonoporation. Further efforts to explore the cellular mechanism of this phenomenon will improve our understanding of sonoporation.postprin

    How sonoporation disrupts cellular structural integrity: morphological and cytoskeletal observations

    Get PDF
    Posters: no. 1Control ID: 1672429OBJECTIVES: In considering sonoporation for drug delivery applications, it is essential to understand how living cells respond to this puncturing force. Here we seek to investigate the effects of sonoporation on cellular structural integrity. We hypothesize that the membrane morphology and cytoskeletal behavior of sonoporated cells under recovery would inherently differ from that of normal viable cells. METHODS: A customized and calibrated exposure platform was developed for this work, and the ZR-75-30 breast carcinoma cells were used as the cell model. The cells were exposed to either single or multiple pulses of 1 MHz ultrasound (pulse length: 30 or 100 cycles; PRF: 1kHz; duration: up to 60s) with 0.45 MPa spatial-averaged peak negative pressure and in the presence of lipid-shelled microbubbles. Confocal microscopy was used to examine insitu the structural integrity of sonoporated cells (identified as ones with exogenous fluorescent marker internalization). For investigations on membrane morphology, FM 4-64 was used as the membrane dye (red), and calcein was used as the sonoporation marker (green); for studies on cytoskeletal behavior, CellLight (green) and propidium iodide (red) were used to respectively label actin filaments and sonoporated cells. Observation started from before exposure to up to 2 h after exposure, and confocal images were acquired at real-time frame rates. Cellular structural features and their temporal kinetics were quantitatively analyzed to assess the consistency of trends amongst a group of cells. RESULTS: Sonoporated cells exhibited membrane shrinkage (decreased by 61% in a cell’s cross-sectional area) and intracellular lipid accumulation (381% increase compared to control) over a 2 h period. The morphological repression of sonoporated cells was also found to correspond with post-sonoporation cytoskeletal processes: actin depolymerization was observed as soon as pores were induced on the membrane. These results show that cellular structural integrity is indeed disrupted over the course of sonoporation. CONCLUSIONS: Our investigation shows that the biophysical impact of sonoporation is by no means limited to the induction of membrane pores: e.g. structural integrity is concomitantly affected in the process. This prompts the need for further fundamental studies to unravel the complex sequence of biological events involved in sonoporation.postprin

    Real-time imaging of cellular dynamics during low-intensity pulsed ultrasound exposure

    Get PDF
    Control ID: 1671584Oral Session 5 - Bioeffects of therapeutic ultrasoundOBJECTIVE: Although the therapeutic potential of low-intensity pulsed ultrasound is unquestionable, the wave-matter interactions involved in the process remain to be vaguely characterized. Here we seek to undertake a series of in-situ cellular imaging studies that aim to analyze the mechanical impact of low-intensity pulsed ultrasound on attached fibroblasts from three different aspects: membrane, cytoskeleton, and nucleus. METHODS: Our experimental platform comprised an in-house ultrasound exposure hardware that was coupled to a confocal microscopy system. The waveguided ultrasound beam was geometrically aligned to the microscope’s fieldof-view that corresponds to the center of a polystyrene dish containing fibroblasts. Short ultrasound pulses (5 cycles; 2 kHz PRF) with 0.8 MPa peak acoustic pressure (0.21 W/cm2 SPTA intensity) were delivered over a 10 min period. Live imaging was performed on both membrane (CellMask) and cytoskeleton (actin-GFP, tubulin-RFP) over the entire observation period (up to 30 min after end of exposure). Also, pre- and post-exposure fixed-cell imaging was conducted on the nucleus (Hoechst 33342) and two cytoskeleton components related to stress fibers: F-actin (phalloidin-FITC) and vincullin (Alexa Fluor 647 conjugated). To study whether mechanotransduction was responsible in mediating ultrasound-cell interactions, some experiments were conducted with the addition of gadolinium that blocks stretch-sensitive ion channels. RESULTS: Cell shrinkage was evident over the course of low-intensity pulsed ultrasound exposure. This was accompanied with contraction of actin and tubulin. Also, an increase in central stress fibers was observed at the end of exposure, while the nucleus was found to have decreased in size. Interestingly, after the exposure, a significant rebound in cell volume was observed over a 30 min. period. These effects were not observed in cases with gadolinium blockage of mechanosensitive ion channels. CONCLUSIONS: Our results suggest that low-intensity pulsed ultrasound would transiently induce remodeling of a cell’s membrane and cytoskeleton, and it will lead to repression of nucleus. This indicates that ultrasound after all represents a mechanical stress on cellular membrane. The post-exposure outgrowth phenomenon is also of practical relevance as it may be linked to the stimulatory effects that have been already observed in low-intensity pulsed ultrasound treatments.postprin

    Proceedings of Abstracts Engineering and Computer Science Research Conference 2019

    Get PDF
    © 2019 The Author(s). This is an open-access work distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. For further details please see https://creativecommons.org/licenses/by/4.0/. Note: Keynote: Fluorescence visualisation to evaluate effectiveness of personal protective equipment for infection control is © 2019 Crown copyright and so is licensed under the Open Government Licence v3.0. Under this licence users are permitted to copy, publish, distribute and transmit the Information; adapt the Information; exploit the Information commercially and non-commercially for example, by combining it with other Information, or by including it in your own product or application. Where you do any of the above you must acknowledge the source of the Information in your product or application by including or linking to any attribution statement specified by the Information Provider(s) and, where possible, provide a link to this licence: http://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/This book is the record of abstracts submitted and accepted for presentation at the Inaugural Engineering and Computer Science Research Conference held 17th April 2019 at the University of Hertfordshire, Hatfield, UK. This conference is a local event aiming at bringing together the research students, staff and eminent external guests to celebrate Engineering and Computer Science Research at the University of Hertfordshire. The ECS Research Conference aims to showcase the broad landscape of research taking place in the School of Engineering and Computer Science. The 2019 conference was articulated around three topical cross-disciplinary themes: Make and Preserve the Future; Connect the People and Cities; and Protect and Care

    Phantoms in medicine: the case of ophthalmology

    Get PDF
    Physical and in-silico phantoms have revealed extremely useful in the development of new surgical techniques and medical devices and for training purposes. The fabrication of eye phantoms requires knowledge of anatomy and physical principles beyond the eye physiology and medical instruments used in the clinical scenario. After a proper definition of phantoms and the discussion about their classification, the present work reviews the various phantoms developed in ophthalmology, illustrating the rationale of their design