9,409 research outputs found

    Classification of osteosarcoma T-ray responses using adaptive and rational wavelets for feature extraction

    Get PDF
    Copyright 2007 Society of Photo-Optical Instrumentation Engineers. This paper was published in Complex Systems II, edited by Derek Abbott, Tomaso Aste, Murray Batchelor, Robert Dewar, Tiziana Di Matteo, Tony Guttmann, Proc. of SPIE Vol. 6802, 680211 and is made available as an electronic reprint with permission of SPIE. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.In this work we investigate new feature extraction algorithms on the T-ray response of normal human bone cells and human osteosarcoma cells. One of the most promising feature extraction methods is the Discrete Wavelet Transform (DWT). However, the classification accuracy is dependant on the specific wavelet base chosen. Adaptive wavelets circumvent this problem by gradually adapting to the signal to retain optimum discriminatory information, while removing redundant information. Using adaptive wavelets, classification accuracy, using a quadratic Bayesian classifier, of 96.88% is obtained based on 25 features. In addition, the potential of using rational wavelets rather than the standard dyadic wavelets in classification is explored. The advantage it has over dyadic wavelets is that it allows a better adaptation of the scale factor according to the signal. An accuracy of 91.15% is obtained through rational wavelets with 12 coefficients using a Support Vector Machine (SVM) as the classifier. These results highlight adaptive and rational wavelets as an efficient feature extraction method and the enormous potential of T-rays in cancer detection.Desmond Ng, Wong Fu Tian, Withawat Withayachumnankul, David Findlay, Bradley Ferguson and Derek Abbot

    A Comparative study of Arabic handwritten characters invariant feature

    Get PDF
    This paper is practically interested in the unchangeable feature of Arabic handwritten character. It presents results of comparative study achieved on certain features extraction techniques of handwritten character, based on Hough transform, Fourier transform, Wavelet transform and Gabor Filter. Obtained results show that Hough Transform and Gabor filter are insensible to the rotation and translation, Fourier Transform is sensible to the rotation but insensible to the translation, in contrast to Hough Transform and Gabor filter, Wavelets Transform is sensitive to the rotation as well as to the translation

    Multiscale Adaptive Representation of Signals: I. The Basic Framework

    Full text link
    We introduce a framework for designing multi-scale, adaptive, shift-invariant frames and bi-frames for representing signals. The new framework, called AdaFrame, improves over dictionary learning-based techniques in terms of computational efficiency at inference time. It improves classical multi-scale basis such as wavelet frames in terms of coding efficiency. It provides an attractive alternative to dictionary learning-based techniques for low level signal processing tasks, such as compression and denoising, as well as high level tasks, such as feature extraction for object recognition. Connections with deep convolutional networks are also discussed. In particular, the proposed framework reveals a drawback in the commonly used approach for visualizing the activations of the intermediate layers in convolutional networks, and suggests a natural alternative

    Relative Facial Action Unit Detection

    Full text link
    This paper presents a subject-independent facial action unit (AU) detection method by introducing the concept of relative AU detection, for scenarios where the neutral face is not provided. We propose a new classification objective function which analyzes the temporal neighborhood of the current frame to decide if the expression recently increased, decreased or showed no change. This approach is a significant change from the conventional absolute method which decides about AU classification using the current frame, without an explicit comparison with its neighboring frames. Our proposed method improves robustness to individual differences such as face scale and shape, age-related wrinkles, and transitions among expressions (e.g., lower intensity of expressions). Our experiments on three publicly available datasets (Extended Cohn-Kanade (CK+), Bosphorus, and DISFA databases) show significant improvement of our approach over conventional absolute techniques. Keywords: facial action coding system (FACS); relative facial action unit detection; temporal information;Comment: Accepted at IEEE Winter Conference on Applications of Computer Vision, Steamboat Springs Colorado, USA, 201

    Improved Stroke Detection at Early Stages Using Haar Wavelets and Laplacian Pyramid

    Get PDF
    Stroke merupakan pembunuh nomor tiga di dunia, namun hanya sedikit metode tentang deteksi dini. Oleh karena itu dibutuhkan metode untuk mendeteksi hal tersebut. Penelitian ini mengusulkan sebuah metode gabungan untuk mendeteksi dua jenis stroke secara simultan. Haar wavelets untuk mendeteksi stroke hemoragik dan Laplacian pyramid untuk mendeteksi stroke iskemik. Tahapan dalam penelitian ini terdiri dari pra proses tahap 1 dan 2, Haar wavelets, Laplacian pyramid, dan perbaikan kualitas citra. Pra proses adalah menghilangkan bagian tulang tengkorak, reduksi derau, perbaikan kontras, dan menghilangkan bagian selain citra otak. Kemudian dilakukan perbaikan citra. Selanjutnya Haar wavelet digunakan untuk ekstraksi daerah hemoragik sedangkan Laplacian pyramid untuk ekstraksi daerah iskemik. Tahapan terakhir adalah menghitung fitur Grey Level Cooccurrence Matrix (GLCM) sebagai fitur untuk proses klasifikasi. Hasil visualisasi diproses lanjut untuk ekstrasi fitur menggunakan GLCM dengan 12 fitur dan kemudian GLCM dengan 4 fitur. Untuk proses klasifikasi digunakan SVM dan KNN, sedangkan pengukuran performa menggunakan akurasi. Jumlah data hemoragik dan iskemik adalah 45 citra yang dibagi menjadi 2 bagian, 28 citra untuk pengujian dan 17 citra untuk pelatihan. Hasil akhir menunjukkan akurasi tertinggi yang dicapai menggunakan SVM adalah 82% dan KNN adalah 88%
    • …
    corecore