1,723 research outputs found

    The first joint ESGAR/ ESPR consensus statement on the technical performance of cross-sectional small bowel and colonic imaging

    Get PDF
    Objectives: To develop guidelines describing a standardised approach to patient preparation and acquisition protocols for magnetic resonance imaging (MRI), computed tomography (CT) and ultrasound (US) of the small bowel and colon, with an emphasis on imaging inflammatory bowel disease. Methods: An expert consensus committee of 13 members from the European Society of Gastrointestinal and Abdominal Radiology (ESGAR) and European Society of Paediatric Radiology (ESPR) undertook a six-stage modified Delphi process, including a detailed literature review, to create a series of consensus statements concerning patient preparation, imaging hardware and image acquisition protocols. Results: One hundred and fifty-seven statements were scored for agreement by the panel of which 129 statements (82 %) achieved immediate consensus with a further 19 (12 %) achieving consensus after appropriate modification. Nine (6 %) statements were rejected as consensus could not be reached. Conclusions: These expert consensus recommendations can be used to help guide cross-sectional radiological practice for imaging the small bowel and colon. Key points: • Cross-sectional imaging is increasingly used to evaluate the bowel • Image quality is paramount to achieving high diagnostic accuracy • Guidelines concerning patient preparation and image acquisition protocols are provided

    Size-specific dose estimates for adult abdomen-pelvis computed tomography examinations in Johor

    Get PDF
    Accurate dose monitoring in computed tomography (CT) is important as CT provides high radiation exposure to the patient compared to other medical imaging modalities. The determination of size-specific dose estimate (SSDE) which takes into account the patient thickness has further facilitated radiation dose calculation in medical field. Present study has been conducted to determine firstly the difference between the average patient size and polymethymethacrylate phantom size, secondly the effects of various patient dimensions on the SSDE, and finally to verify the relationship between the SSDE and the volume CT dose index (CTDIvol), as well as that of between the SSDE and the patient size. One hundred abdomen-pelvis CT images have been utilized for coefficient of variation (CV) analysis using different patients’ thickness measurements. Descriptive statistics and Mann-Whitney test have been used to obtain the significant difference, p values. Simple linear regression model was plotted to determine the correlation between the SSDE and CTDIvol, as well as that of between the SSDE and patient’s thickness by referring to the summation of anterior-posterior and lateral (AP+Lateral) diameter. Routine abdomen-pelvis protocols considered in this study are in agreement with guidelines with a mean SSDE and CTDIvol of 15.5 ± 4.1 mGy and 11.4 ± 4.6 mGy, respectively. The SSDEs measured on the axial image and localizer radiograph show no significant difference, while the SSDEs derived from AP+Lateral diameter show a lower CV compared to other size descriptors, thus the latter is recommended to be used in the future SSDE calculation. Results show that the SSDE provides a better measure of the patient radiation dose value than the CTDIvol. It reduces the underestimation and overestimation problems of using phantoms in calculation of the CTDIvol. In conclusion, a promising approach using the SSDE as a measure of patient radiation dose can provide accurate dose estimation in clinical study compared to other approach based on the CTDIvol

    Whole-body imaging of the musculoskeletal system: the value of MR imaging

    Get PDF
    In clinical practice various modalities are used for whole-body imaging of the musculoskeletal system, including radiography, bone scintigraphy, computed tomography, magnetic resonance imaging (MRI), and positron emission tomography-computed tomography (PET-CT). Multislice CT is far more sensitive than radiographs in the assessment of trabecular and cortical bone destruction and allows for evaluation of fracture risk. The introduction of combined PET-CT scanners has markedly increased diagnostic accuracy for the detection of skeletal metastases compared with PET alone. The unique soft-tissue contrast of MRI enables for precise assessment of bone marrow infiltration and adjacent soft tissue structures so that alterations within the bone marrow may be detected before osseous destruction becomes apparent in CT or metabolic changes occur on bone scintigraphy or PET scan. Improvements in hard- and software, including parallel image acquisition acceleration, have made high resolution whole-body MRI clinically feasible. Whole-body MRI has successfully been applied for bone marrow screening of metastasis and systemic primary bone malignancies, like multiple myeloma. Furthermore, it has recently been proposed for the assessment of systemic bone diseases predisposing for malignancy (e.g., multiple cartilaginous exostoses) and muscle disease (e.g., muscle dystrophy). The following article gives an overview on state-of-the-art whole-body imaging of the musculoskeletal system and highlights present and potential future applications, especially in the field of whole-body MRI

    Iterative reconstruction as a novel method of radiation dose reduction at computed tomography in patients with Crohn's disease

    Get PDF
    Prior work of our research group, that quantified the alarming levels of radiation dose to patients with Crohn’s disease from medical imaging and the notable shift towards CT imaging making these patients an at risk group, provided context for this work. CT delivers some of the highest doses of ionising radiation in diagnostic radiology. Once a medical imaging examination is deemed justified, there is an onus on the imaging team to endeavour to produce diagnostic quality CT images at the lowest possible radiation dose to that patient. The fundamental limitation with conventional CT raw data reconstruction was the inherent coupling of administered radiation dose with observed image noise – the lower the radiation dose, the noisier the image. The renaissance, rediscovery and refinement of iterative reconstruction removes this limitation allowing either an improvement in image quality without increasing radiation dose or maintenance of image quality at a lower radiation dose compared with traditional image reconstruction. This thesis is fundamentally an exercise in optimisation in clinical CT practice with the objectives of assessment of iterative reconstruction as a method for improvement of image quality in CT, exploration of the associated potential for radiation dose reduction, and development of a new split dose CT protocol with the aim of achieving and validating diagnostic quality submillisiever t CT imaging in patients with Crohn’s disease. In this study, we investigated the interplay of user-selected parameters on radiation dose and image quality in phantoms and cadavers, comparing traditional filtered back projection (FBP) with iterative reconstruction algorithms. This resulted in the development of an optimised, refined and appropriate split dose protocol for CT of the abdomen and pelvis in clinical patients with Crohn’s disease allowing contemporaneous acquisition of both modified and conventional dose CT studies. This novel algorithm was then applied to 50 patients with a suspected acute complication of known Crohn’s disease and the raw data reconstructed with FBP, adaptive statistical iterative reconstruction (ASiR) and model based iterative reconstruction (MBIR). Conventional dose CT images with FBP reconstruction were used as the reference standard with which the modified dose CT images were compared in terms of radiation dose, diagnostic findings and image quality indices. As there are multiple possible user-selected strengths of ASiR available, these were compared in terms of image quality to determine the optimal strength for this modified dose CT protocol. Modified dose CT images with MBIR were also compared with contemporaneous abdominal radiograph, where performed, in terms of diagnostic yield and radiation dose. Finally, attenuation measurements in organs, tissues, etc. with each reconstruction algorithm were compared to assess for preservation of tissue characterisation capabilities. In the phantom and cadaveric models, both forms of iterative reconstruction examined (ASiR and MBIR) were superior to FBP across a wide variety of imaging protocols, with MBIR superior to ASiR in all areas other than reconstruction speed. We established that ASiR appears to work to a target percentage noise reduction whilst MBIR works to a target residual level of absolute noise in the image. Modified dose CT images reconstructed with both ASiR and MBIR were non-inferior to conventional dose CT with FBP in terms of diagnostic findings, despite reduced subjective and objective indices of image quality. Mean dose reductions of 72.9-73.5% were achieved with the modified dose protocol with a mean effective dose of 1.26mSv. MBIR was again demonstrated superior to ASiR in terms of image quality. The overall optimal ASiR strength for the modified dose protocol used in this work is ASiR 80%, as this provides the most favourable balance of peak subjective image quality indices with less objective image noise than the corresponding conventional dose CT images reconstructed with FBP. Despite guidelines to the contrary, abdominal radiographs are still often used in the initial imaging of patients with a suspected complication of Crohn’s disease. We confirmed the superiority of modified dose CT with MBIR over abdominal radiographs at comparable doses in detection of Crohn’s disease and non-Crohn’s disease related findings. Finally, we demonstrated (in phantoms, cadavers and in vivo) that attenuation values do not change significantly across reconstruction algorithms meaning preserved tissue characterisation capabilities with iterative reconstruction. Both adaptive statistical and model based iterative reconstruction algorithms represent feasible methods of facilitating acquisition diagnostic quality CT images of the abdomen and pelvis in patients with Crohn’s disease at markedly reduced radiation doses. Our modified dose CT protocol allows dose savings of up to 73.5% compared with conventional dose CT, meaning submillisievert imaging is possible in many of these patients

    Towards patient-specific dose and image quality analysis in CT imaging

    Get PDF

    Patient radiation dose issues resulting from the use of CT in the UK

    Get PDF
    In this report, COMARE presents a comprehensive review of the radiation dose issues associated with CT scans in the UK. The implications of the increase in the numbers of CT scans in the UK are considered in the report, with focus on the number of younger patients undergoing CT scans, who have greater sensitivity to x-rays. The report provides an update on the radiation protection aspects of justification (balancing risk and benefit) and optimisation (balancing the risk from the radiation dose with the quality of the image)

    The Optimisation of Routine Paediatric CT Scanning Protocols

    Get PDF
    This study represents one of the first comprehensive paediatric optimisation processes that were systematically approached via three main objectives. It is expected that the devised optimisation paediatric protocols could have profound implications on clinical practices that use 64-slice CT or greater. The study provides a better understanding of the influence of each acquisition reconstruction parameter with regards to image quality and radiation dose during routine paediatric imaging protocols

    Ionizing Radiation in Medical Imaging and Efforts in Dose Optimization

    Get PDF
    Medical-related radiation is the largest source of controllable radiation exposure to humans and it accounts for more than 95% of radiation exposure from man-made sources. Its direct benefits in modern day medical practices are beyond doubt but risks-benefits ratios need to be constantly monitored as the use of ionizing radiation is increasing rapidly. From 1980 to 2006, the per-capita effective dose from diagnostic and interventional medical procedures in the United States increased almost six fold, from 0.5 to 3.0mSv, while contributions from other sources remained static (NCRP report no 160, 2009). This chapter will review radiation exposure from medical imaging initially starting from a historical viewpoint as well as discussing innovative technologies on the horizon. The challenges for the medical community in addressing the increasing trend of radiation usage will be discussed as well as the latest research in dose justification and optimization.link_to_OA_fulltex
    • …