10 research outputs found
Hierarchical template matching for 3D myocardial tracking and cardiac strain estimation
Myocardial tracking and strain estimation can non-invasively assess cardiac functioning using subject-specific MRI. As the left-ventricle does not have a uniform shape and functioning from base to apex, the development of 3D MRI has provided opportunities for simultaneous 3D tracking, and 3D strain estimation. We have extended a Local Weighted Mean (LWM) transformation function for 3D, and incorporated in a Hierarchical Template Matching model to solve 3D myocardial tracking and strain estimation problem. The LWM does not need to solve a large system of equations, provides smooth displacement of myocardial points, and adapt local geometric differences in images. Hence, 3D myocardial tracking can be performed with 1.49 mm median error, and without large error outliers. The maximum error of tracking is up to 24% reduced compared to benchmark methods. Moreover, the estimated strain can be insightful to improve 3D imaging protocols, and the computer code of LWM could also be useful for geo-spatial and manufacturing image analysis researchers
QUANTITATIVE ELASTICITY IMAGING AND SOFT TISSUE CHARACTERIZATION USING TAGGED MAGNETIC RESONANCE IMAGING
Ph.DDOCTOR OF PHILOSOPH
Cardiac image computing for myocardial infarction patients
Cardiovascular diseases (CVDs), which are a prime cause of global mortality, are disorders that affect the heart and blood vessels' functioning. CVDs may cause consequent complications, due to occlusion in a blood vessel and present as impaired cardiac wall functioning (myocardium). Identifying such impairment (infarction) of the myocardium is of great clinical interest, as it can reveal the nature of altered cardiac topography (ventricular remodelling) to aid the associated intervention decisions.
With recent advances in cardiac imaging, such as Magnetic Resonance (MR) imaging, the visualisation and identification of infarcted myocardium has been routinely and effectively used in clinical practice. Diagnosing infarcted myocardium is achieved clinically through the late gadolinium enhancement (LGE) test, which acquires MR images after injecting a gadolinium-based contrast agent (GBCA). Due to the increased accuracy and reproducibility, LGE has emerged as the gold-standard MR imaging test in identifying myocardial infarction. However, clinical studies have reported gadolinium deposition concerns in different body organs and adverse outcomes in patients with advanced kidney failure, over time. Such incidents have motivated researchers to look into the development of both accurate as well as safe diagnostic tools.
Emerging research on identifying infarcted myocardium utilises myocardial strain to safely identify infarcted myocardium, which has been addressed in the presented study. For example, myocardial strain represents the shortening or lengthening of the myocardium. If the myocardium is infarcted, then the corresponding strain values differ compared to the healthy myocardium. This finding can be identified and utilised for clinical applications. The research presented in this thesis aims to identify infarcted myocardium accurately and safely by using myocardial strain (shortening or lengthening of the myocardium).
To achieve the aforementioned aim, the research methodology is divided into six objectives. The initial objectives relate to the development of a novel myocardial tracking method. The middle objectives relate to the development of clinical application methods, and the final objectives concern the validation of the developed methods through clinical studies and associated datasets. The research presented in this thesis has addressed the following research question:
Research question 1: How can a 2D myocardial tracking and strain calculation method be developed using the 2D local weighted mean function and structural deformation within the myocardium?
Research question 2: How can a 3D myocardial tracking and strain calculation method be developed using the 3D local weighted mean function to calculate 3D myocardial strain?
Research question 3: How can 2D circumferential strain of the myocardium be used in identifying infarcted left ventricular segments for the diagnosis of myocardial infarction patients?
In literature, myocardial tracking and strain calculation methods have limited extension to 3D and dependency on tissue material properties. Moreover, additional limitations, such as limited inclusion of structural deformation details within the myocardium, are found in the literature. Therefore, methods are likely to become subjective or numerically unstable during computation. Moreover, the inclusion of myocardial details with grid-tagging MRI, for structural deformation within the myocardium, is more realistic compared to cine MRI.
The aforementioned limitations are overcome by proposing a novel Hierarchical Template Matching method, which performs non-rigid image registration among grid-tagging MR images of a cardiac cycle. This is achieved by employing a local weighted mean transformation function. The proposed non-rigid image registration method does not require the use of tissue material properties. Grid-tagging MRI is used to capture wall function within the myocardium, and the local weighted mean function is used for numerical stability. The performance of the developed methods is evaluated with multiple error measures and with a benchmark framework. This benchmark framework has provided an open-access 3D dataset, a set of validation methods, and results of four leading methods for comparison. Validation methods include qualitative and quantitative methods. The qualitative assessment of outcomes and verified ground truth for the quantitative evaluation of results are followed from the benchmark framework paper (Tobon-Gomez, Craene, Mcleod, et al., 2013).
2D HTM method has reported the root mean square error of point tracking in left ventricular slices, which are the basal slice 0.31±0.07 mm, the upper mid-ventricular slice 0.37±0.06 mm, the mid-ventricular slice 0.41±0.05 mm, and the apical slice 0.32±0.08 mm. The mid-ventricular slice has a significantly higher 4% (P=0.05) mean root mean square error compared to the other slices. However, the other slices do not have a significant difference among them. Compared to the benchmark free form deformation method, HTM has a mean error of 0.35±0.05 mm, which is 17% (P=0.07, CI:[-0.01,0.35]) reduced to the free form deformation method.
Our technical method has shown the 3D extension of HTM and a method without using material properties, which is advantageous compared to the methods which are limited to 2D or dependent on material properties. Moreover, the 3D HTM has demonstrated the use of 3D local weighted mean function in 3D myocardial tracking. While comparing to the benchmark methods, it was found that the median tracking error of 3D HTM is comparable to benchmark methods and has very few outliers compared to them.
The clinical results are validated with LGE imaging. The quantitative error measure is the area under the curve (AUC) of sensitivity vs 1-specificity curve of the receiver operating characteristic (ROC) test. The achieved AUC value in detecting infarcted segments in basal, mid-ventricular, and apical slices are 0.85, 0.82, and 0.87, respectively. Calculating AUC with 95% confidence level, the confidence intervals of lower and upper mean AUC values in basal, mid-ventricular and apical slices are [0.80, 0.89], [0.74, 0.85], and [0.78, 0.91], respectively. Overall, considering the detections of LGE imaging as the base, our method has an accuracy of AUC 0.73 (P=0.05) in identifying infarcted left ventricular segments.
The developed methods have shown, systematically, a promising approach in identifying infarcted left ventricular segments by image processing method and without using GBCA-based LGE imaging.
An image segmentation and registration approach to cardiac function analysis using MRI
Cardiovascular diseases (CVDs) are one of the major causes of death in the world. In recent
years, significant progress has been made in the care and treatment of patients with such
diseases. A crucial factor for this progress has been the development of magnetic resonance
(MR) imaging which makes it possible to diagnose and assess the cardiovascular function
of the patient. The ability to obtain high-resolution, cine volume images easily and safely
has made it the preferred method for diagnosis of CVDs. MRI is also unique in its ability
to introduce noninvasive markers directly into the tissue being imaged(MR tagging) during
the image acquisition process. With the development of advanced MR imaging acquisition
technologies, 3D MR imaging is more and more clinically feasible. This recent development has
allowed new potentially 3D image analysis technologies to be deployed. However, quantitative
analysis of cardiovascular system from the images remains a challenging topic.
The work presented in this thesis describes the development of segmentation and motion
analysis techniques for the study of the cardiac anatomy and function in cardiac magnetic
resonance (CMR) images. The first main contribution of the thesis is the development of a fully
automatic cardiac segmentation technique that integrates and combines a series of state-of-the-art
techniques. The proposed segmentation technique is capable of generating an accurate 3D
segmentation from multiple image sequences. The proposed segmentation technique is robust
even in the presence of pathological changes, large anatomical shape variations and locally
varying contrast in the images.
Another main contribution of this thesis is the development of motion tracking techniques that
can integrate motion information from different sources. For example, the radial motion of
the myocardium can be tracked easily in untagged MR imaging since the epi- and endocardial
surfaces are clearly visible. On the other hand, tagged MR imaging allows easy tracking of
both longitudinal and circumferential motion. We propose a novel technique based on non-rigid
image registration for the myocardial motion estimation using both untagged and 3D tagged MR
images. The novel aspect of our technique is its simultaneous use of complementary information
from both untagged and 3D tagged MR imaging. The similarity measure is spatially weighted
to maximise the utility of information from both images.
The thesis also proposes a sparse representation for free-form deformations (FFDs) using the principles of compressed sensing. The sparse free-form deformation (SFFD) model can
capture fine local details such as motion discontinuities without sacrificing robustness. We
demonstrate the capabilities of the proposed framework to accurately estimate smooth as well
as discontinuous deformations in 2D and 3D CMR image sequences. Compared to the standard
FFD approach, a significant increase in registration accuracy can be observed in datasets with
discontinuous motion patterns.
Both the segmentation and motion tracking techniques presented in this thesis have been
applied to clinical studies. We focus on two important clinical applications that can be
addressed by the techniques proposed in this thesis. The first clinical application aims
at measuring longitudinal changes in cardiac morphology and function during the cardiac
remodelling process. The second clinical application aims at selecting patients that positively
respond to cardiac resynchronization therapy (CRT).
The final chapter of this thesis summarises the main conclusions that can be drawn from the
work presented here and also discusses possible avenues for future research