2,044 research outputs found

    Image-guided port placement for minimally invasive cardiac surgery

    Get PDF
    Minimally invasive surgery is becoming popular for a number of interventions. Use of robotic surgical systems in coronary artery bypass intervention offers many benefits to patients, but is however limited by remaining challenges in port placement. Choosing the entry ports for the robotic tools has a large impact on the outcome of the surgery, and can be assisted by pre-operative planning and intra-operative guidance techniques. In this thesis, pre-operative 3D computed tomography (CT) imaging is used to plan minimally invasive robotic coronary artery bypass (MIRCAB) surgery. From a patient database, port placement optimization routines are implemented and validated. Computed port placement configurations approximated past expert chosen configurations with an error of 13.7 ±5.1 mm. Following optimization, statistical classification was used to assess patient candidacy for MIRCAB. Various pattern recognition techniques were used to predict MIRCAB success, and could be used in the future to reduce conversion rates to conventional open-chest surgery. Gaussian, Parzen window, and nearest neighbour classifiers all proved able to detect ‘candidate’ and ‘non-candidate’ MIRCAB patients. Intra-operative registration and laser projection of port placements was validated on a phantom and then evaluated in four patient cases. An image-guided laser projection system was developed to map port placement plans from pre-operative 3D images. Port placement mappings on the phantom setup were accurate with an error of 2.4 ± 0.4 mm. In the patient cases, projections remained within 1 cm of computed port positions. Misregistered port placement mappings in human trials were due mainly to the rigid-body registration assumption and can be improved by non-rigid techniques. Overall, this work presents an integrated approach for: 1) pre-operative port placement planning and classification of incoming MIRCAB patients; and 2) intra-operative guidance of port placement. Effective translation of these techniques to the clinic will enable MIRCAB as a more efficacious and accessible procedure

    The Role of Visualization, Force Feedback, and Augmented Reality in Minimally Invasive Heart Valve Repair

    Get PDF
    New cardiovascular techniques have been developed to address the unique requirements of high risk, elderly, surgical patients with heart valve disease by avoiding both sternotomy and cardiopulmonary bypass. However, these technologies pose new challenges in visualization, force application, and intracardiac navigation. Force feedback and augmented reality (AR) can be applied to minimally invasive mitral valve repair and transcatheter aortic valve implantation (TAVI) techniques to potentially surmount these challenges. Our study demonstrated shorter operative times with three dimensional (3D) visualization compared to two dimensional (2D) visualization; however, both experts and novices applied significantly more force to cardiac tissue during 3D robotics-assisted mitral valve annuloplasty than during conventional open mitral valve annuloplasty. This finding suggests that 3D visualization does not fully compensate for the absence of haptic feedback in robotics-assisted cardiac surgery. Subsequently, using an innovative robotics-assisted surgical system design, we determined that direct haptic feedback may improve both expert and trainee performance using robotics-assisted techniques. We determined that during robotics-assisted mitral valve annuloplasty the use of either visual or direct force feedback resulted in a significant decrease in forces applied to cardiac tissue when compared to robotics-assisted mitral valve annuloplasty without force feedback. We presented NeoNav, an AR-enhanced echocardiograpy intracardiac guidance system for NeoChord off-pump mitral valve repair. Our study demonstrated superior tool navigation accuracy, significantly shorter navigation times, and reduced potential for injury with AR enhanced intracardiac navigation for off-pump transapical mitral valve repair with neochordae implantation. In addition, we applied the NeoNav system as a safe and inexpensive alternative imaging modality for TAVI guidance. We found that our proposed AR guidance system may achieve similar or better results than the current standard of care, contrast enhanced fluoroscopy, while eliminating the use of nephrotoxic contrast and ionizing radiation. These results suggest that the addition of both force feedback and augmented reality image guidance can improve both surgical performance and safety during minimally invasive robotics assisted and beating heart valve surgery, respectively

    Virtual and Augmented Reality Techniques for Minimally Invasive Cardiac Interventions: Concept, Design, Evaluation and Pre-clinical Implementation

    Get PDF
    While less invasive techniques have been employed for some procedures, most intracardiac interventions are still performed under cardiopulmonary bypass, on the drained, arrested heart. The progress toward off-pump intracardiac interventions has been hampered by the lack of adequate visualization inside the beating heart. This thesis describes the development, assessment, and pre-clinical implementation of a mixed reality environment that integrates pre-operative imaging and modeling with surgical tracking technologies and real-time ultrasound imaging. The intra-operative echo images are augmented with pre-operative representations of the cardiac anatomy and virtual models of the delivery instruments tracked in real time using magnetic tracking technologies. As a result, the otherwise context-less images can now be interpreted within the anatomical context provided by the anatomical models. The virtual models assist the user with the tool-to-target navigation, while real-time ultrasound ensures accurate positioning of the tool on target, providing the surgeon with sufficient information to ``see\u27\u27 and manipulate instruments in absence of direct vision. Several pre-clinical acute evaluation studies have been conducted in vivo on swine models to assess the feasibility of the proposed environment in a clinical context. Following direct access inside the beating heart using the UCI, the proposed mixed reality environment was used to provide the necessary visualization and navigation to position a prosthetic mitral valve on the the native annulus, or to place a repair patch on a created septal defect in vivo in porcine models. Following further development and seamless integration into the clinical workflow, we hope that the proposed mixed reality guidance environment may become a significant milestone toward enabling minimally invasive therapy on the beating heart

    New perspectives in surgical treatment of aortic diseases

    Get PDF

    Dynamic Image Processing for Guidance of Off-pump Beating Heart Mitral Valve Repair

    Get PDF
    Compared to conventional open heart procedures, minimally invasive off-pump beating heart mitral valve repair aims to deliver equivalent treatment for mitral regurgitation with reduced trauma and side effects. However, minimally invasive approaches are often limited by the lack of a direct view to surgical targets and/or tools, a challenge that is compounded by potential movement of the target during the cardiac cycle. For this reason, sophisticated image guidance systems are required in achieving procedural efficiency and therapeutic success. The development of such guidance systems is associated with many challenges. For example, the system should be able to provide high quality visualization of both cardiac anatomy and motion, as well as augmenting it with virtual models of tracked tools and targets. It should have the capability of integrating pre-operative images to the intra-operative scenario through registration techniques. The computation speed must be sufficiently fast to capture the rapid cardiac motion. Meanwhile, the system should be cost effective and easily integrated into standard clinical workflow. This thesis develops image processing techniques to address these challenges, aiming to achieve a safe and efficient guidance system for off-pump beating heart mitral valve repair. These techniques can be divided into two categories, using 3D and 2D image data respectively. When 3D images are accessible, a rapid multi-modal registration approach is proposed to link the pre-operative CT images to the intra-operative ultrasound images. The ultrasound images are used to display the real time cardiac motion, enhanced by CT data serving as high quality 3D context with annotated features. I also developed a method to generate synthetic dynamic CT images, aiming to replace real dynamic CT data in such a guidance system to reduce the radiation dose applied to the patients. When only 2D images are available, an approach is developed to track the feature of interest, i.e. the mitral annulus, based on bi-plane ultrasound images and a magnetic tracking system. The concept of modern GPU-based parallel computing is employed in most of these approaches to accelerate the computation in order to capture the rapid cardiac motion with desired accuracy. Validation experiments were performed on phantom, animal and human data. The overall accuracy of registration and feature tracking with respect to the mitral annulus was about 2-3mm with computation time of 60-400ms per frame, sufficient for one update per cardiac cycle. It was also demonstrated in the results that the synthetic CT images can provide very similar anatomical representations and registration accuracy compared to that of the real dynamic CT images. These results suggest that the approaches developed in the thesis have good potential for a safer and more effective guidance system for off-pump beating heart mitral valve repair

    New perspectives in surgical treatment of aortic diseases

    Get PDF

    Current Trends and Future Developments in Robotic Cardiac Surgery

    Get PDF
    Robotic Cardiac Surgery has revolutionised operating for surgeons to provide less operative pain, shorter hospital stays and improved quality of life. As surgeons are constantly trying new techniques, Robotic Cardiac Surgery now encompasses mitral valve surgery, coronary revascularisation, atrial fibrillation surgery, pacing lead implantation, congenital cardiac operations, cardiac tumours resection and diaphragmatic pacing. Robotic technology is gradually becoming more affordable and so more centres are investing in training surgeons in these techniques. As a result, robotic cardiac surgery has developed into a rapidly evolving speciality with exciting new possibilities... (excerpt

    Medical Robotics

    Get PDF
    The first generation of surgical robots are already being installed in a number of operating rooms around the world. Robotics is being introduced to medicine because it allows for unprecedented control and precision of surgical instruments in minimally invasive procedures. So far, robots have been used to position an endoscope, perform gallbladder surgery and correct gastroesophogeal reflux and heartburn. The ultimate goal of the robotic surgery field is to design a robot that can be used to perform closed-chest, beating-heart surgery. The use of robotics in surgery will expand over the next decades without any doubt. Minimally Invasive Surgery (MIS) is a revolutionary approach in surgery. In MIS, the operation is performed with instruments and viewing equipment inserted into the body through small incisions created by the surgeon, in contrast to open surgery with large incisions. This minimizes surgical trauma and damage to healthy tissue, resulting in shorter patient recovery time. The aim of this book is to provide an overview of the state-of-art, to present new ideas, original results and practical experiences in this expanding area. Nevertheless, many chapters in the book concern advanced research on this growing area. The book provides critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies. This book is certainly a small sample of the research activity on Medical Robotics going on around the globe as you read it, but it surely covers a good deal of what has been done in the field recently, and as such it works as a valuable source for researchers interested in the involved subjects, whether they are currently “medical roboticists” or not

    Estimating Target Vessel Location on Robot-Assisted CABG using Feature-based CT to US Registration

    Get PDF
    Although robot-assisted coronary artery bypass grafting (RA-CABG) has gained more acceptance worldwide, its success still depends on the surgeon’s experience and expertise, and the conversion rate to full sternotomy is in the order of 15%—25%. One of the reasons for conversion is poor pre-operative planning, which is based solely on pre-operative computed tomography (CT) images. This thesis proposes a technique to estimate the global peri-operative displacement of the heart and to predict the intra-operative target vessel location. The technique has been validated via both an in vitro and a clinical study, and predicted the position of the peri-operative target vessel location with ~ 3.5 mm RMS accuracy in the in vitro study while it yielded ~ 5.0 mm accuracy for the clinical validation. As the desired clinical accuracy imposed by this procedure is on the order of one intercostal space (10 - 15 mm), our technique suits the clinical requirements. It is therefore believed that this technique has the potential to improve the pre-operative planning by updating peri-operative migration patterns of the heart and, consequently, will lead to reduced conversion to conventional open thoracic procedures
    corecore