242 research outputs found
A neural probe with up to 966 electrodes and up to 384 configurable channels in 0.13 μm SOI CMOS
In vivo recording of neural action-potential and local-field-potential signals requires the use of high-resolution penetrating probes. Several international initiatives to better understand the brain are driving technology efforts towards maximizing the number of recording sites while minimizing the neural probe dimensions. We designed and fabricated (0.13-μm SOI Al CMOS) a 384-channel configurable neural probe for large-scale in vivo recording of neural signals. Up to 966 selectable active electrodes were integrated along an implantable shank (70 μm wide, 10 mm long, 20 μm thick), achieving a crosstalk of −64.4 dB. The probe base (5 × 9 mm2) implements dual-band recording and a 1
Communication channel analysis and real time compressed sensing for high density neural recording devices
Next generation neural recording and Brain-
Machine Interface (BMI) devices call for high density or distributed
systems with more than 1000 recording sites. As the
recording site density grows, the device generates data on the
scale of several hundred megabits per second (Mbps). Transmitting
such large amounts of data induces significant power
consumption and heat dissipation for the implanted electronics.
Facing these constraints, efficient on-chip compression techniques
become essential to the reduction of implanted systems power
consumption. This paper analyzes the communication channel
constraints for high density neural recording devices. This paper
then quantifies the improvement on communication channel
using efficient on-chip compression methods. Finally, This paper
describes a Compressed Sensing (CS) based system that can
reduce the data rate by > 10x times while using power on
the order of a few hundred nW per recording channel
Active C4 electrodes for local field potential recording applications
Extracellular neural recording, with multi-electrode arrays (MEAs), is a powerful method used to study neural function at the network level. However, in a high density array, it can be costly and time consuming to integrate the active circuit with the expensive electrodes. In this paper, we present a 4 mm × 4 mm neural recording integrated circuit (IC) chip, utilizing IBM C4 bumps as recording electrodes, which enable a seamless active chip and electrode integration. The IC chip was designed and fabricated in a 0.13 μm BiCMOS process for both in vitro and in vivo applications. It has an input-referred noise of 4.6 μV rms for the bandwidth of 10 Hz to 10 kHz and a power dissipation of 11.25 mW at 2.5 V, or 43.9 μW per input channel. This prototype is scalable for implementing larger number and higher density electrode arrays. To validate the functionality of the chip, electrical testing results and acute in vivo recordings from a rat barrel cortex are presented.R01 NS072385 - NINDS NIH HHS; 1R01 NS072385 - NINDS NIH HH
Time Multiplexed Active Neural Probe with 678 Parallel Recording Sites
We present a high density CMOS neural probe with
active electrodes (pixels), consisting of dedicated in-situ circuits
for signal source amplification. The complete probe contains 1356
neuron size (20x20 μm2) pixels densely packed on a 50 μm thick,
100 μm wide and 8 mm long shank. It allows simultaneous highperformance
recording from 678 electrodes and a possibility to
simultaneously observe all of the 1356 electrodes with increased
noise. This considerably surpasses the state of the art active neural
probes in electrode count and flexibility. The measured action
potential band noise is 12.4 μVrms, with just 3 μW power
dissipation per electrode amplifier and 45 μW per channel
(including data transmission)
Recent Progress of Development of Optogenetic Implantable Neural Probes
As a cell type-specific neuromodulation method, optogenetic technique holds remarkable potential for the realisation of advanced neuroprostheses. By genetically expressing light-sensitive proteins such as channelrhodopsin-2 (ChR2) in cell membranes, targeted neurons could be controlled by light. This new neuromodulation technique could then be applied into extensive brain networks and be utilised to provide effective therapies for neurological disorders. However, the development of novel optogenetic implants is still a key challenge in the field. The major requirements include small device dimensions, suitable spatial resolution, high safety, and strong controllability. In this paper, I present a concise review of the significant progress that has been made towards achieving a miniaturised, multifunctional, intelligent optogenetic implant. I identify the key limitations of current technologies and discuss the possible opportunities for future development
Design Considerations of a Sub-50 {\mu}W Receiver Front-end for Implantable Devices in MedRadio Band
Emerging health-monitor applications, such as information transmission
through multi-channel neural implants, image and video communication from
inside the body etc., calls for ultra-low active power (<50W) high
data-rate, energy-scalable, highly energy-efficient (pJ/bit) radios. Previous
literature has strongly focused on low average power duty-cycled radios or low
power but low-date radios. In this paper, we investigate power performance
trade-off of each front-end component in a conventional radio including active
matching, down-conversion and RF/IF amplification and prioritize them based on
highest performance/energy metric. The analysis reveals 50 active
matching and RF gain is prohibitive for 50W power-budget. A mixer-first
architecture with an N-path mixer and a self-biased inverter based baseband
LNA, designed in TSMC 65nm technology show that sub 50W performance can
be achieved up to 10Mbps (< 5pJ/b) with OOK modulation.Comment: Accepted to appear on International Conference on VLSI Design 2018
(VLSID
Materials and neuroscience: validating tools for large-scale, high-density neural recording
Extracellular recording remains the only technique capable of measuring the activity of many neurons simultaneously with a sub-millisecond precision, in multiple brain areas, including deep structures. Nevertheless, many questions about the nature of the detected signal and the limitations/capabilities of this technique remain unanswered.
The general goal of this work is to apply the methodology and concepts of materials science to answer some of the major questions surrounding extracellular recording, and thus take full advantage of this seminal technique.
We start out by quantifying the effect of electrode impedance on the amplitude of measured extracellular spikes and background noise. Can we improve data quality by lowering electrode impedance? We demonstrate that if the proper recording system is used, then the impedance of a microelectrode, within the range typical of standard polytrodes (~ 0.1 to 2 MΩ), does not significantly affect a neural spike amplitude or the background noise, and therefore spike sorting.
In addition to improving the performance of each electrode, increasing the number of electrodes in a single neural probe has also proven advantageous for simultaneously monitoring the activity of more neurons with better spatiotemporal resolution. How can we achieve large-scale, highdensity extracellular recordings without compromising brain tissue? Here we report the design and in vivo validation of a complementary metal–oxide–semiconductor (CMOS)-based scanning probe with 1356 electrodes arranged along approximately 8 mm of a thin shaft (50 μm thick and 100 μm wide). Additionally, given the ever-shrinking dimensions of CMOS technology, there is a drive to fabricate sub-cellular electrodes (< 10 μm). Therefore, to evaluate electrode configurations for future probe designs, several recordings from many different brain regions were performed with an ultra-dense probe containing 255 electrodes, each with a geometric area of 5 x 5 μm and a pitch of 6 μm.
How can we validate neural probes with different electrode materials/configurations and different sorting algorithms? We describe a new procedure for precisely aligning two probes for in vivo “paired-recordings” such that the spiking activity of a single neuron is monitored with both a dense extracellular silicon polytrode and a juxtacellular micro-pipette. We gathered a dataset of paired-recordings, which is available online. The “ground truth” data, for which one knows exactly when a neuron in the vicinity of an extracellular probe generates an action potential, has been used for several groups to validate and quantify the performance of new algorithms to automatically detect/sort single-units
On the way to large-scale and high-resolution brain-chip interfacing
Brain-chip-interfaces (BCHIs) are hybrid entities where chips and nerve cells establish a close physical interaction allowing the transfer of information in one or both directions. Typical examples are represented by multi-site-recording chips interfaced to cultured neurons, cultured/acute brain slices, or implanted “in vivo”. This paper provides an overview on recent achievements in our laboratory in the field of BCHIs leading to enhancement of signals transmission from nerve cells to chip or from chip to nerve cells with an emphasis on in vivo interfacing, either in terms of signal-to-noise ratio or of spatiotemporal resolution. Oxide-insulated chips featuring large-scale and high-resolution arrays of stimulation and recording elements are presented as a promising technology for high spatiotemporal resolution interfacing, as recently demonstrated by recordings obtained from hippocampal slices and brain cortex in implanted animals. Finally, we report on an automated tool for processing and analysis of acquired signals by BCHIs
- …