11,745 research outputs found

    A Survey of Techniques For Improving Energy Efficiency in Embedded Computing Systems

    Full text link
    Recent technological advances have greatly improved the performance and features of embedded systems. With the number of just mobile devices now reaching nearly equal to the population of earth, embedded systems have truly become ubiquitous. These trends, however, have also made the task of managing their power consumption extremely challenging. In recent years, several techniques have been proposed to address this issue. In this paper, we survey the techniques for managing power consumption of embedded systems. We discuss the need of power management and provide a classification of the techniques on several important parameters to highlight their similarities and differences. This paper is intended to help the researchers and application-developers in gaining insights into the working of power management techniques and designing even more efficient high-performance embedded systems of tomorrow

    BSLD threshold driven parallel job scheduling for energy efficient HPC centers

    Get PDF
    Recently, power awareness in high performance computing (HPC) community has increased significantly. While CPU power reduction of HPC applications using Dynamic Voltage Frequency Scaling (DVFS) has been explored thoroughly, CPU power management for large scale parallel systems at system level has left unexplored. In this paper we propose a power-aware parallel job scheduler assuming DVFS enabled clusters. Traditional parallel job schedulers determine when a job will be run, power aware ones should assign CPU frequency which it will be run at. We have introduced two adjustable thresholds in order to enable fine grain energy performance trade-off control. Since our power reduction approach is policy independent it can be added to any parallel job scheduling policy. Furthermore, we have done an analysis of HPC system dimension. Running an application at lower frequency on more processors can be more energy efficient than running it at the highest CPU frequency on less processors. This paper investigates whether having more DVFS enabled processors and same load can lead to better energy efficiency and performance. Five workload logs from systems in production use with up to 9 216 processors are simulated to evaluate the proposed algorithm and the dimensioning problem. Our approach decreases CPU energy by 7%- 18% on average depending on allowed job performance penalty. Applying the same frequency scaling algorithm on 20% larger system, CPU energy needed to execute same load can be decreased by almost 30% while having same or better job performance.Postprint (published version

    Low Power Processor Architectures and Contemporary Techniques for Power Optimization – A Review

    Get PDF
    The technological evolution has increased the number of transistors for a given die area significantly and increased the switching speed from few MHz to GHz range. Such inversely proportional decline in size and boost in performance consequently demands shrinking of supply voltage and effective power dissipation in chips with millions of transistors. This has triggered substantial amount of research in power reduction techniques into almost every aspect of the chip and particularly the processor cores contained in the chip. This paper presents an overview of techniques for achieving the power efficiency mainly at the processor core level but also visits related domains such as buses and memories. There are various processor parameters and features such as supply voltage, clock frequency, cache and pipelining which can be optimized to reduce the power consumption of the processor. This paper discusses various ways in which these parameters can be optimized. Also, emerging power efficient processor architectures are overviewed and research activities are discussed which should help reader identify how these factors in a processor contribute to power consumption. Some of these concepts have been already established whereas others are still active research areas. © 2009 ACADEMY PUBLISHER

    Power Management Techniques for Data Centers: A Survey

    Full text link
    With growing use of internet and exponential growth in amount of data to be stored and processed (known as 'big data'), the size of data centers has greatly increased. This, however, has resulted in significant increase in the power consumption of the data centers. For this reason, managing power consumption of data centers has become essential. In this paper, we highlight the need of achieving energy efficiency in data centers and survey several recent architectural techniques designed for power management of data centers. We also present a classification of these techniques based on their characteristics. This paper aims to provide insights into the techniques for improving energy efficiency of data centers and encourage the designers to invent novel solutions for managing the large power dissipation of data centers.Comment: Keywords: Data Centers, Power Management, Low-power Design, Energy Efficiency, Green Computing, DVFS, Server Consolidatio

    Dynamic and Leakage Power-Composition Profile Driven Co-Synthesis for Energy and Cost Reduction

    No full text
    Recent research has shown that combining dynamic voltage scaling (DVS) and adaptive body bias (ABB) techniques achieve the highest reduction in embedded systems energy dissipation [1]. In this paper we show that it is possible to produce comparable energy saving to that obtained using combined DVS and ABB techniques but with reduced hardware cost achieved by employing processing elements (PEs) with separate DVS or ABB capability. A co-synthesis methodology which is aware of tasks’ power-composition profile (the ratio of the dynamic power to the leakage power) is presented. The methodology selects voltage scaling capabilities (DVS, ABB, or combined DVS and ABB) for the PEs, maps, schedules, and voltage scales applications given as task graphs with timing constraints, aiming to dynamic and leakage energy reduction at low hardware cost. We conduct detailed experiments, including a real-life example, to demonstrate the effectiveness of our methodology. We demonstrate that it is possible to produce designs that contain PEs with only DVS or ABB technique but have energy dissipation that are only 4.4% higher when compared with the same designs that employ PEs with combined DVS and ABB capabilities

    MORA: an Energy-Aware Slack Reclamation Scheme for Scheduling Sporadic Real-Time Tasks upon Multiprocessor Platforms

    Full text link
    In this paper, we address the global and preemptive energy-aware scheduling problem of sporadic constrained-deadline tasks on DVFS-identical multiprocessor platforms. We propose an online slack reclamation scheme which profits from the discrepancy between the worst- and actual-case execution time of the tasks by slowing down the speed of the processors in order to save energy. Our algorithm called MORA takes into account the application-specific consumption profile of the tasks. We demonstrate that MORA does not jeopardize the system schedulability and we show by performing simulations that it can save up to 32% of energy (in average) compared to execution without using any energy-aware algorithm.Comment: 11 page

    Dynamic Voltage Scaling Techniques for Energy Efficient Synchronized Sensor Network Design

    Get PDF
    Building energy-efficient systems is one of the principal challenges in wireless sensor networks. Dynamic voltage scaling (DVS), a technique to reduce energy consumption by varying the CPU frequency on the fly, has been widely used in other settings to accomplish this goal. In this paper, we show that changing the CPU frequency can affect timekeeping functionality of some sensor platforms. This phenomenon can cause an unacceptable loss of time synchronization in networks that require tight synchrony over extended periods, thus preventing all existing DVS techniques from being applied. We present a method for reducing energy consumption in sensor networks via DVS, while minimizing the impact of CPU frequency switching on time synchronization. The system is implemented and evaluated on a network of 11 Imote2 sensors mounted on a truss bridge and running a high-fidelity continuous structural health monitoring application. Experimental measurements confirm that the algorithm significantly reduces network energy consumption over the same network that does not use DVS, while requiring significantly fewer re-synchronization actions than a classic DVS algorithm.unpublishedis peer reviewe
    • …
    corecore