337 research outputs found
Accelerated High-Resolution Photoacoustic Tomography via Compressed Sensing
Current 3D photoacoustic tomography (PAT) systems offer either high image
quality or high frame rates but are not able to deliver high spatial and
temporal resolution simultaneously, which limits their ability to image dynamic
processes in living tissue. A particular example is the planar Fabry-Perot (FP)
scanner, which yields high-resolution images but takes several minutes to
sequentially map the photoacoustic field on the sensor plane, point-by-point.
However, as the spatio-temporal complexity of many absorbing tissue structures
is rather low, the data recorded in such a conventional, regularly sampled
fashion is often highly redundant. We demonstrate that combining variational
image reconstruction methods using spatial sparsity constraints with the
development of novel PAT acquisition systems capable of sub-sampling the
acoustic wave field can dramatically increase the acquisition speed while
maintaining a good spatial resolution: First, we describe and model two general
spatial sub-sampling schemes. Then, we discuss how to implement them using the
FP scanner and demonstrate the potential of these novel compressed sensing PAT
devices through simulated data from a realistic numerical phantom and through
measured data from a dynamic experimental phantom as well as from in-vivo
experiments. Our results show that images with good spatial resolution and
contrast can be obtained from highly sub-sampled PAT data if variational image
reconstruction methods that describe the tissues structures with suitable
sparsity-constraints are used. In particular, we examine the use of total
variation regularization enhanced by Bregman iterations. These novel
reconstruction strategies offer new opportunities to dramatically increase the
acquisition speed of PAT scanners that employ point-by-point sequential
scanning as well as reducing the channel count of parallelized schemes that use
detector arrays.Comment: submitted to "Physics in Medicine and Biology
Enhancing Compressed Sensing 4D Photoacoustic Tomography by Simultaneous Motion Estimation
A crucial limitation of current high-resolution 3D photoacoustic tomography
(PAT) devices that employ sequential scanning is their long acquisition time.
In previous work, we demonstrated how to use compressed sensing techniques to
improve upon this: images with good spatial resolution and contrast can be
obtained from suitably sub-sampled PAT data acquired by novel acoustic scanning
systems if sparsity-constrained image reconstruction techniques such as total
variation regularization are used. Now, we show how a further increase of image
quality can be achieved for imaging dynamic processes in living tissue (4D
PAT). The key idea is to exploit the additional temporal redundancy of the data
by coupling the previously used spatial image reconstruction models with
sparsity-constrained motion estimation models. While simulated data from a
two-dimensional numerical phantom will be used to illustrate the main
properties of this recently developed
joint-image-reconstruction-and-motion-estimation framework, measured data from
a dynamic experimental phantom will also be used to demonstrate their potential
for challenging, large-scale, real-world, three-dimensional scenarios. The
latter only becomes feasible if a carefully designed combination of tailored
optimization schemes is employed, which we describe and examine in more detail
Investigation of iterative image reconstruction in three-dimensional optoacoustic tomography
Iterative image reconstruction algorithms for optoacoustic tomography (OAT),
also known as photoacoustic tomography, have the ability to improve image
quality over analytic algorithms due to their ability to incorporate accurate
models of the imaging physics, instrument response, and measurement noise.
However, to date, there have been few reported attempts to employ advanced
iterative image reconstruction algorithms for improving image quality in
three-dimensional (3D) OAT. In this work, we implement and investigate two
iterative image reconstruction methods for use with a 3D OAT small animal
imager: namely, a penalized least-squares (PLS) method employing a quadratic
smoothness penalty and a PLS method employing a total variation norm penalty.
The reconstruction algorithms employ accurate models of the ultrasonic
transducer impulse responses. Experimental data sets are employed to compare
the performances of the iterative reconstruction algorithms to that of a 3D
filtered backprojection (FBP) algorithm. By use of quantitative measures of
image quality, we demonstrate that the iterative reconstruction algorithms can
mitigate image artifacts and preserve spatial resolution more effectively than
FBP algorithms. These features suggest that the use of advanced image
reconstruction algorithms can improve the effectiveness of 3D OAT while
reducing the amount of data required for biomedical applications
Quantitative photoacoustic imaging in radiative transport regime
The objective of quantitative photoacoustic tomography (QPAT) is to
reconstruct optical and thermodynamic properties of heterogeneous media from
data of absorbed energy distribution inside the media. There have been
extensive theoretical and computational studies on the inverse problem in QPAT,
however, mostly in the diffusive regime. We present in this work some numerical
reconstruction algorithms for multi-source QPAT in the radiative transport
regime with energy data collected at either single or multiple wavelengths. We
show that when the medium to be probed is non-scattering, explicit
reconstruction schemes can be derived to reconstruct the absorption and the
Gruneisen coefficients. When data at multiple wavelengths are utilized, we can
reconstruct simultaneously the absorption, scattering and Gruneisen
coefficients. We show by numerical simulations that the reconstructions are
stable.Comment: 40 pages, 13 figure
A Multi-Grid Iterative Method for Photoacoustic Tomography
Inspired by the recent advances on minimizing nonsmooth or bound-constrained
convex functions on models using varying degrees of fidelity, we propose a line
search multigrid (MG) method for full-wave iterative image reconstruction in
photoacoustic tomography (PAT) in heterogeneous media. To compute the search
direction at each iteration, we decide between the gradient at the target
level, or alternatively an approximate error correction at a coarser level,
relying on some predefined criteria. To incorporate absorption and dispersion,
we derive the analytical adjoint directly from the first-order acoustic wave
system. The effectiveness of the proposed method is tested on a total-variation
penalized Iterative Shrinkage Thresholding algorithm (ISTA) and its accelerated
variant (FISTA), which have been used in many studies of image reconstruction
in PAT. The results show the great potential of the proposed method in
improving speed of iterative image reconstruction
On the Adjoint Operator in Photoacoustic Tomography
Photoacoustic Tomography (PAT) is an emerging biomedical "imaging from
coupled physics" technique, in which the image contrast is due to optical
absorption, but the information is carried to the surface of the tissue as
ultrasound pulses. Many algorithms and formulae for PAT image reconstruction
have been proposed for the case when a complete data set is available. In many
practical imaging scenarios, however, it is not possible to obtain the full
data, or the data may be sub-sampled for faster data acquisition. In such
cases, image reconstruction algorithms that can incorporate prior knowledge to
ameliorate the loss of data are required. Hence, recently there has been an
increased interest in using variational image reconstruction. A crucial
ingredient for the application of these techniques is the adjoint of the PAT
forward operator, which is described in this article from physical, theoretical
and numerical perspectives. First, a simple mathematical derivation of the
adjoint of the PAT forward operator in the continuous framework is presented.
Then, an efficient numerical implementation of the adjoint using a k-space time
domain wave propagation model is described and illustrated in the context of
variational PAT image reconstruction, on both 2D and 3D examples including
inhomogeneous sound speed. The principal advantage of this analytical adjoint
over an algebraic adjoint (obtained by taking the direct adjoint of the
particular numerical forward scheme used) is that it can be implemented using
currently available fast wave propagation solvers.Comment: submitted to "Inverse Problems
- …