111 research outputs found

    Patient-Specific Neurovascular Simulator for Evaluating the Performance of Medical Robots and Instrumens

    Get PDF
    Proceedings of the 2006 IEEE International Conference on Robotics and Automation, Orlando, Florida, May 200

    Photoelastic Stress Analysis Error Quantification in Vasculature Models for Robot Feedback Control

    Get PDF
    Abstract-Real-time and accurate stress calculation in walls of vasculature is desired to provide catheter insertion robots of feedback control without changing the catheter stiffness and lumen. This feedback source has also applications in endovascular surgery simulation for human skills and medical tools evaluation. For that purpose we consider photoelastic effect, as birefringence produced by light retardation relates with the stress inside the photoelastic materials. In this research a polariscope was designed for urethane elastomer vasculature models, the photoelastic coefficient of urethane elastomer was measured, and the camera system was calibrated to quantify and reduce error of the measurement system. An average error of 3.6% was found for the pressure range of 70-189 mmHg inside the model of urethane elastomer, this enables to calculate accurately stress in vasculature models during Human Blood Pressure Simulation (HBPS). That way we will be able to compare in a closed loop stress produced by HBPS and by the catheter motion when manipulated by a robot. I. INTRODUCTION RAINING with simulators reduces risks of injury and costs during practice for minimally invasive surgery C. Tercero is with Nagoya University, Aiichi-ken Nagoya-shi Chikusa-ku Furo-cho 1, 464-8603 JAPAN (phone: +81-52-788-6013; fax: +81-52-788-6013; e-mail: [email protected]). S. Ikeda is with Nagoya University, Aiichi-ken Nagoya-shi Chikusa-ku Furo-cho 1, 464-8603 JAPAN (phone: +81-52-788-6013; fax: +81-52-788-6013; e-mail: ikeda @robo.mein.nagoya-u.ac.jp). In previous studies photoelastic effect was used with a catheter insertion robot to evaluate catheters In this research we will present a calibration method for the transmittance equation to measure the optical path length, a polariscope designed for our simulation purpose, the deduction of the photoelastic coefficient of urethane elastomer, and the normalization parameters calibration to calculate the principal component of stress in the vasculature model with an inner pressure range of 40-189mmHg. It is desirable to measure stress with an error below 5% for the HBPS range, to use it as reference for control loop illustrated in figure 2. Photoelastic Stress Analysis Error Quantification i

    Front Lines of Thoracic Surgery

    Get PDF
    Front Lines of Thoracic Surgery collects up-to-date contributions on some of the most debated topics in today's clinical practice of cardiac, aortic, and general thoracic surgery,and anesthesia as viewed by authors personally involved in their evolution. The strong and genuine enthusiasm of the authors was clearly perceptible in all their contributions and I'm sure that will further stimulate the reader to understand their messages. Moreover, the strict adhesion of the authors' original observations and findings to the evidence base proves that facts are the best guarantee of scientific value. This is not a standard textbook where the whole discipline is organically presented, but authors' contributions are simply listed in their pertaining subclasses of Thoracic Surgery. I'm sure that this original and very promising editorial format which has and free availability at its core further increases this book's value and it will be of interest to healthcare professionals and scientists dedicated to this field

    Medical Robotics

    Get PDF
    The first generation of surgical robots are already being installed in a number of operating rooms around the world. Robotics is being introduced to medicine because it allows for unprecedented control and precision of surgical instruments in minimally invasive procedures. So far, robots have been used to position an endoscope, perform gallbladder surgery and correct gastroesophogeal reflux and heartburn. The ultimate goal of the robotic surgery field is to design a robot that can be used to perform closed-chest, beating-heart surgery. The use of robotics in surgery will expand over the next decades without any doubt. Minimally Invasive Surgery (MIS) is a revolutionary approach in surgery. In MIS, the operation is performed with instruments and viewing equipment inserted into the body through small incisions created by the surgeon, in contrast to open surgery with large incisions. This minimizes surgical trauma and damage to healthy tissue, resulting in shorter patient recovery time. The aim of this book is to provide an overview of the state-of-art, to present new ideas, original results and practical experiences in this expanding area. Nevertheless, many chapters in the book concern advanced research on this growing area. The book provides critical analysis of clinical trials, assessment of the benefits and risks of the application of these technologies. This book is certainly a small sample of the research activity on Medical Robotics going on around the globe as you read it, but it surely covers a good deal of what has been done in the field recently, and as such it works as a valuable source for researchers interested in the involved subjects, whether they are currently “medical roboticists” or not

    CT Scanning

    Get PDF
    Since its introduction in 1972, X-ray computed tomography (CT) has evolved into an essential diagnostic imaging tool for a continually increasing variety of clinical applications. The goal of this book was not simply to summarize currently available CT imaging techniques but also to provide clinical perspectives, advances in hybrid technologies, new applications other than medicine and an outlook on future developments. Major experts in this growing field contributed to this book, which is geared to radiologists, orthopedic surgeons, engineers, and clinical and basic researchers. We believe that CT scanning is an effective and essential tools in treatment planning, basic understanding of physiology, and and tackling the ever-increasing challenge of diagnosis in our society
    corecore