13,861 research outputs found
Adaptive gray scale mapping to reduce registration noise in difference images
Difference images are used in various image processing applications such as change detection, radar imaging, remote sensing, and biomedical image analysis. The difference image, or difference picture, is found by subtracting one image from another. One practical problem with difference images is that, if the images are not in perfect spatial registration before subtraction, their difference image will contain artifacts caused by incomplete cancellation of the unchanged background objects. These artifacts (registration noise) show up as extraneous light and dark regions on either side of the background objects. Usually, this noise is reduced by either smoothing (blurring), or thresholding the difference image. This paper describes a new method to reduce registration noise using adaptive gray scale mapping. This simple digital filter reduces registration noise as well as, or better than, previous methods, with less degradation of the actual differences between the images.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/26272/1/0000357.pd
Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates
The study of cerebral anatomy in developing neonates is of great importance for
the understanding of brain development during the early period of life. This
dissertation therefore focuses on three challenges in the modelling of cerebral
anatomy in neonates during brain development. The methods that have been
developed all use Magnetic Resonance Images (MRI) as source data.
To facilitate study of vascular development in the neonatal period, a set of image
analysis algorithms are developed to automatically extract and model cerebral
vessel trees. The whole process consists of cerebral vessel tracking from
automatically placed seed points, vessel tree generation, and vasculature
registration and matching. These algorithms have been tested on clinical Time-of-
Flight (TOF) MR angiographic datasets.
To facilitate study of the neonatal cortex a complete cerebral cortex segmentation
and reconstruction pipeline has been developed. Segmentation of the neonatal
cortex is not effectively done by existing algorithms designed for the adult brain
because the contrast between grey and white matter is reversed. This causes pixels
containing tissue mixtures to be incorrectly labelled by conventional methods. The
neonatal cortical segmentation method that has been developed is based on a novel
expectation-maximization (EM) method with explicit correction for mislabelled
partial volume voxels. Based on the resulting cortical segmentation, an implicit
surface evolution technique is adopted for the reconstruction of the cortex in
neonates. The performance of the method is investigated by performing a detailed
landmark study.
To facilitate study of cortical development, a cortical surface registration algorithm
for aligning the cortical surface is developed. The method first inflates extracted
cortical surfaces and then performs a non-rigid surface registration using free-form
deformations (FFDs) to remove residual alignment. Validation experiments using
data labelled by an expert observer demonstrate that the method can capture local
changes and follow the growth of specific sulcus
Medical imaging analysis with artificial neural networks
Given that neural networks have been widely reported in the research community of medical imaging, we provide a focused literature survey on recent neural network developments in computer-aided diagnosis, medical image segmentation and edge detection towards visual content analysis, and medical image registration for its pre-processing and post-processing, with the aims of increasing awareness of how neural networks can be applied to these areas and to provide a foundation for further research and practical development. Representative techniques and algorithms are explained in detail to provide inspiring examples illustrating: (i) how a known neural network with fixed structure and training procedure could be applied to resolve a medical imaging problem; (ii) how medical images could be analysed, processed, and characterised by neural networks; and (iii) how neural networks could be expanded further to resolve problems relevant to medical imaging. In the concluding section, a highlight of comparisons among many neural network applications is included to provide a global view on computational intelligence with neural networks in medical imaging
Digital Color Imaging
This paper surveys current technology and research in the area of digital
color imaging. In order to establish the background and lay down terminology,
fundamental concepts of color perception and measurement are first presented
us-ing vector-space notation and terminology. Present-day color recording and
reproduction systems are reviewed along with the common mathematical models
used for representing these devices. Algorithms for processing color images for
display and communication are surveyed, and a forecast of research trends is
attempted. An extensive bibliography is provided
Calibrating a high-resolution wavefront corrector with a static focal-plane camera
We present a method to calibrate a high-resolution wavefront-correcting
device with a single, static camera, located in the focal plane; no moving of
any component is needed. The method is based on a localized diversity and
differential optical transfer functions (dOTF) to compute both the phase and
amplitude in the pupil plane located upstream of the last imaging optics. An
experiment with a spatial light modulator shows that the calibration is
sufficient to robustly operate a focal-plane wavefront sensing algorithm
controlling a wavefront corrector with ~40 000 degrees of freedom. We estimate
that the locations of identical wavefront corrector elements are determined
with a spatial resolution of 0.3% compared to the pupil diameter.Comment: 12 pages, 12 figures, accepted for publication in Applied Optic
An Adaptive Semi-Parametric and Context-Based Approach to Unsupervised Change Detection in Multitemporal Remote-Sensing Images
In this paper, a novel automatic approach to the unsupervised identification of changes in multitemporal remote-sensing images is proposed. This approach, unlike classical ones, is based on the formulation of the unsupervised change-detection problem in terms of the Bayesian decision theory. In this context, an adaptive semi-parametric technique for the unsupervised estimation of the statistical terms associated with the gray levels of changed and unchanged pixels in a difference image is presented. Such a technique exploits the effectivenesses of two theoretically well-founded estimation procedures: the reduced Parzen estimate (RPE) procedure and the expectation-maximization (EM) algorithm. Then, thanks to the resulting estimates and to a Markov Random Field (MRF) approach used to model the spatial-contextual information contained in the multitemporal images considered, a change detection map is generated. The adaptive semi-parametric nature of the proposed technique allows its application to different kinds of remote-sensing images. Experimental results, obtained on two sets of multitemporal remote-sensing images acquired by two different sensors, confirm the validity of the proposed approach
Enhancing retinal images by nonlinear registration
Being able to image the human retina in high resolution opens a new era in
many important fields, such as pharmacological research for retinal diseases,
researches in human cognition, nervous system, metabolism and blood stream, to
name a few. In this paper, we propose to share the knowledge acquired in the
fields of optics and imaging in solar astrophysics in order to improve the
retinal imaging at very high spatial resolution in the perspective to perform a
medical diagnosis. The main purpose would be to assist health care
practitioners by enhancing retinal images and detect abnormal features. We
apply a nonlinear registration method using local correlation tracking to
increase the field of view and follow structure evolutions using correlation
techniques borrowed from solar astronomy technique expertise. Another purpose
is to define the tracer of movements after analyzing local correlations to
follow the proper motions of an image from one moment to another, such as
changes in optical flows that would be of high interest in a medical diagnosis.Comment: 21 pages, 7 figures, submitted to Optics Communication
- …