983 research outputs found

    Adaptive ac filter parameters identification for voltage-oriented control of three-phase voltage-source rectifiers

    Get PDF
    This paper proposes an adaptive voltage-oriented control (VOC) with online ac filter parameters identification for three-phase voltage-source rectifier (VSR). A new method based on adaptive linear neuron (ADALINE) is first designed to identify the ac filter parameters. For accurate identification, the VSR nonlinearity is included in the ADALINE structure. Thereafter, the developed ADALINE is inserted in the VOC to realise an adaptive VOC. Thus, the decoupled terms and the proportional-integral current controller gains are updated online. Finally, the ADALINE ability to track properly the ac filter parameters is investigated by experimental analysis. It shows that the VSR nonlinearity consideration has significant influence on the resistance identification. Compared to the VOC, the enhancement of the proposed adaptive VOC is experimentally proved. The originality of this paper is the building of a VSR model including VSR nonlinearity that is suitable for implementation with ADALINE. This leads to ease of implementation and accurate identification

    Sliding mode approach for control and observation of a three phase AC-DC pulse-width modulation rectifier

    Get PDF
    Introduction. For AC-DC conversion systems, the electrical systems typically use thyristor or diode bridge rectifiers, which have relatively poor performance. Nowadays, three-phase pulse-width modulation rectifiers are widely applied in various applications for their well-known intrinsic benefits, such as adjustable DC link voltage, unity power factor, bidirectional power flow and very low total harmonic distortion. Purpose. The objective of this work is to achieve better stability and dynamic performance using sliding mode strategy for control and observation. Methods. For that purpose, first a sliding mode controller is introduced on the DC-link side to ensure a fast and accurate response of the output load voltage. Then, the sliding mode approach is employed to control the quadrature and direct components of power to maintain the input power factor at unity. Finally, this approach is used to design two observers for grid voltage estimation and online variation of load resistance. To overcome the problem associated with the use of the classical low-pass filter, an adaptive compensation algorithm is used to compensate the attenuation of the amplitude and phase delay of the observed grid voltages. This algorithm is based on the use of the two low-pass filters in cascade and ensures the minimization of chattering. Results. Comparative studies have been carried out between sliding mode control method for controlling the three-phase AC-DC pulse-width modulation rectifier and other conventional techniques. The validation by simulation and the tests carried out gave very satisfactory results and proved the effectiveness and feasibility of the sliding mode for both control and observation of three phase pulse-width modulation rectifier.Вступ. Для AC-DC систем перетворення електричні системи зазвичай використовують тиристорні або діодні мостові випрямлячі, які мають відносно погані характеристики. В даний час трифазні випрямлячі з широтно-імпульсною модуляцією широко застосовуються з різними цілями завдяки їх добре відомим внутрішнім перевагам, таким як регульована напруга у ланці постійного струму, одиничний коефіцієнт потужності, двонаправлений потік потужності та дуже низькі загальні гармонічні спотворення. Метою даної роботи є досягнення кращої стабільності та динамічних характеристик з використанням стратегії ковзного режиму для контролю та спостереження. Методи. З цією метою спочатку на стороні ланки постійного струму вводиться регулятор режиму ковзання, щоб забезпечити швидку і точну реакцію на вихідну напругу навантаження. Потім використовується метод ковзного режиму для управління квадратурною та прямою складовими потужності, щоб підтримувати вхідний коефіцієнт потужності рівним одиниці. Нарешті цей підхід використовується для розробки двох спостерігачів для оцінки напруги мережі та зміни опору навантаження в режимі онлайн. Для подолання проблеми, пов'язаної з використанням класичного низькочастотного фільтру, використовується алгоритм адаптивної компенсації, що компенсує загасання амплітуди і фазової затримки напруг мережі, що спостерігаються. Цей алгоритм заснований на використанні двох низькочастотних фільтрів у каскаді та забезпечує мінімізацію брязкоту. Результати. Були проведені порівняльні дослідження між методом керування ковзним режимом для керування трифазним випрямлячем AC-DC з широтно-імпульсною модуляцією та іншими традиційними методами. Перевірка за допомогою моделювання та проведені випробування дали дуже задовільні результати та довели ефективність та здійсненність ковзного режиму як для управління, так і для спостереження за трифазним випрямлячем з широтно-імпульсною модуляцією

    Grid Voltages Estimation for Three-Phase PWM Rectifiers Control Without AC Voltage Sensors

    Get PDF
    This paper proposes a new ac voltage sensorless control scheme for the three-phase pulse-width modulation rectifier. A new startup process to ensure a smooth starting of the system is also proposed. The sensorless control scheme uses an adaptive neural (AN) estimator inserted in voltage-oriented control to eliminate the grid voltage sensors. The developed AN estimator combines an AN network in series with an AN filter. The AN estimator structure leads to simple, accurate, and fast grid voltages estimation, and makes it ideal for low-cost digital signal processor implementation. Lyapunov-based stability and parameters tuning of the AN estimator are performed. Simulation and experimental tests are carried out to verify the feasibility and effectiveness of the AN estimator. Obtained results show that the proposed AN estimator presented faster convergence and better accuracy than the second-order generalized integrator-based estimator; the new startup procedure avoided the overcurrent and reduced the settling time; and the AN estimator presented high performances even under distorted and unbalanced grid voltages

    Sensorless Predictive Direct Power Control PDPC_SVM For PWM Converter Under Different Input Voltage Conditions

    Get PDF
    In this paper, a new virtual flux (VF) based predictive direct power control (VF_PDPC) applied for three-phase pulse width modulation (PWM) rectifier is proposed. The virtual flux estimation is performed using a pure integrator in series with a new adaptive algorithm in order to cancel dc offset and harmonic distortions in the estimated VF. The introduced structure is able to produce two virtual flux positive sequence components orthogonal output signals under unbalanced and distorted voltage conditions. The main features of the proposed virtual flux estimator are, it's simple structure, accuracy, and fast VF estimation over the excited integrators. Therefore,  the estimated VF is then used for robust sensorless VF-PDPC with a constant switching frequency using space vector modulation (SVM) and tested through numerical simulations. The instantaneous active and reactive powers provided by orthogonal (VF) positive sequence components are directly controlled. More importantly, this configuration gives quasi-sinusoidal and balanced current under different input voltage conditions without using the power compensation methods. The results of the simulation confirmed the validity of the proposed virtual flux algorithm and demonstrated excellent performance under different input voltage conditions, complete rejection of disturbances

    A Review on Direct Power Control of Pulsewidth Modulation Converters

    Get PDF

    Model Predictive Observer Based Control for Single-Phase Asymmetrical T-Type AC/DC Power Converter

    Full text link
    © 1972-2012 IEEE. This paper presents a robust control strategy for the control of single-phase five-level asymmetrical T-type ac/dc power converter. A cascaded control scheme consisting of a finite control set model predictive control (FCS-MPC) with an extended state observer (ESO) is proposed to govern the converter. In this scheme, a proportional integral (PI) controller combined with an ESO-based disturbance observer is employed as an external control loop. This control loop dynamically modifies the active power reference to realize the desired operating point of the system state (converter output voltage). The proposed control system presents a high degree of disturbance rejection capability and robustness against the external disturbances to the converter, whereas the conventional PI control performance suffers in the presence of these disturbances. In this paper, the inner current tracking loop is accomplished by an FCS-MPC algorithm. This algorithm is derived to force the input currents to track the reference values while realizing a user-defined reactive power and maintaining balanced voltages in the series-connected capacitors. Theoretical analysis and the design procedure of the proposed control system are presented. Finally, experimental studies are conducted to verify the effectiveness of the proposed control scheme

    Grid voltage sensorless model-based predictive power control of PWM rectifiers based on sliding mode virtual flux observer

    Full text link
    © 2013 IEEE. In this paper, a grid voltage sensorless model predictive control is proposed based on a sliding mode virtual flux observer (SMVFO). The proposed SMVFO shows good inherent filtering capacity, and thus there is no high-frequency chattering problem. In addition, the proposed SMVFO is designed based on the closed-loop current estimation. Not only is DC-drift issue solved but also dynamic response is enhanced when compared with the prior open-loop virtual flux observer. To verify the effectiveness of the presented SMVFO, it is further integrated into finite control set-model predictive control (FCS-MPC) for pulse width modulator (PWM) rectifiers. The whole control algorithm features simplicity and improved cost-effectiveness due to the absence of modulator and grid voltage sensors. As the SMVFO can predict current at the next sampling instant while estimating virtual flux accurately, the proposed SMVFO assisted FCS-MPC is comparable to its counterpart using measured grid voltage. The simulation and experimental tests were carried out on a two-level voltage source PWM rectifier to validate the effectiveness of the proposed method

    Enhanced Phase-Shifted Current Control for Harmonic Cancellation in Three-Phase Multiple Adjustable Speed Drive Systems

    Get PDF
    A phase-shifted current control can be employed to mitigate certain harmonics induced by the diode rectifiers and silicon-controlled rectifiers as the front ends of multiple parallel adjustable speed drive (ASD) systems. However, the effectiveness of the phase-shifted control relies on the loading condition of each drive unit as well as the number of drives in parallel. In order to enhance the harmonic cancellation by means of the phase-shifted current control, the currents drawn by the rectifiers should be maintained almost at the same level. Thus, this paper first analyzes the impact of unequal loading among the parallel drives, and a scheme to enhance the performance is introduced to improve the quality of the total grid current, where partial loading operation should be enabled. Simulation and experimental case studies on multidrive systems have demonstrated that the enhanced phase-shifted current control is a cost-effective solution to multiple ASD systems in terms of harmonic cancellation

    Control strategy of grid connected power converter based on virtual flux approach

    Get PDF
    A la portada consta el nom del programa interuniversitari: Joint Doctoral Programme in Electric Energy Systems [by the] Universidad de Málaga, Universidad de Sevilla, Universidad del País Vasco/Euskal Erriko Unibertsitatea i Universitat Politècnica de CatalunyaDistributed Generation (DG) provides an alternative to the Centralized Generation (CG) by means of generating electricity near to the end user of power with the employment of small-scale technologies to produce electricity, mainly using Renewable Energy Sources (RES). The prospects of renewable energy integration during the next years are still very optimistic. This PhD dissertation is made to provide an alternative control framework for the grid connected power converter by adopting the virtual flux concept in the control layer. This dissertation can be divided into three main topics. The 1st topic presents the voltage sensorless control system for the grid-connected power converter. The control system presented is done without depending on AC-voltage measurement where the grid synchronization is based on the Virtual Flux (VF) estimation. In this regard, the Frequency Locked Loop (FLL) is used in conjunction with the estimation scheme to make the system fully adaptive to the frequency changes. This voltage sensorless application is useful for reducing cost and complexity of the control hardware. It is also can be utilized in case of limited reliability or availability of voltage measurements at the intended point of synchronization to the grid. Considering that most previous studies are based on the VF estimation for the case of power converter connected to the grid through the L-filter or LC-filter, this dissertation is focused on the power converter connected to the grid through the LCL filter. The Proportional Resonant (PR) current controller is adopted in the inner loop control of the power electronics-based converter to test the performance of such system. Another control method based on VF synchronization that permits to control the active and reactive power delivery in a remote point of the grid is also presented in this dissertation. This is due to the fact that the VF is implemented that the voltage in a remote point of the line can be estimated. As it will be shown in simulations and experiments, the proposed control scheme provides a good tracking and dynamic performance under step changes in the reference power. The fast synchronization and the smooth reference tracking achieved in transient conditions have demonstrated the effectiveness of the Dual Second Order Generalized Integrator controlled as Quadrature Signal Generator (DSOGI-QSG) and also the current controller used in the proposed system. In addition to the power control itself, this study could also benefit the frequency and the voltage regulation methods in distributed generation applications as for instance in microgrid. Considering the fact that the grid connected power converter can be controlled as a virtual synchronous generator where the flux is a variable to be used for controlling its operation, this dissertation also presents a Virtual Synchronous Flux Controller (VSFC) as a new control framework of the grid connected power converter. In this regard, a new control strategy in the inner loop control of the power converter will be proposed. The main components of the outer loop control of VSFC are based on the active and reactive power control. The results presented show that the VSFC works well to control the active and reactive power without considering any synchronization system. The inner loop control is able to work as it is required, and the measurement flux is able to track the reference flux without any significant delays. All the work presented in this dissertation are supported by mathematical and simulation analysis. In order to endorse the conclusions achieved, a complete experimental validations have been conducted before wrapping this dissertation with a conclusion and recommendation for future enhancement of the control strategies that have been presented.Postprint (published version
    corecore