109 research outputs found

    Variable bit rate voice over ATM using compression and silence removal

    Get PDF
    Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 1997.Includes bibliographical references (leaves 45-46).by Mario A. Yearwood.M.Eng

    Satellite Networks: Architectures, Applications, and Technologies

    Get PDF
    Since global satellite networks are moving to the forefront in enhancing the national and global information infrastructures due to communication satellites' unique networking characteristics, a workshop was organized to assess the progress made to date and chart the future. This workshop provided the forum to assess the current state-of-the-art, identify key issues, and highlight the emerging trends in the next-generation architectures, data protocol development, communication interoperability, and applications. Presentations on overview, state-of-the-art in research, development, deployment and applications and future trends on satellite networks are assembled

    Coordinated Control of Distributed Energy Resources in Islanded Microgrids

    Get PDF
    As the penetration of the distributed energy resources (DERs) in the power grid increases,new challenges are revealed, including: stability issues, frequency fluctuations, voltage control, protection system coordination, etc. A systematic approach for dealing with those issues is to view the DERs and associated loads as a subsystem or a microgrid (MG). MGs can operate either in the grid connected or islanded modes. As opposed to the grid connected mode, the voltage and frequency regulation and load/generation balancing during islanded mode is solely dependent on the local generation units. Therefore, stable and reliable operation of islanded MGs requires a real time coordinated control scheme. Conventionally, such coordination is achieved by means of the active power-frequency and reactive powervoltage droop control schemes. The conventional droop method, which is based on P-f droop concept in power systems, lacks compatibility with the resistive nature of networks as well as the low inertia of electronically interfaced DER units in MGs. As a result, it features a slow dynamic response but also a low power quality due to frequency and voltage fluctuations. This PhD research proposes a novel droop concept based on the global positioning system (GPS) and voltage-current (V-I) droop characteristics for coordination of inverter-based DER units in islanded MGs. The concept of V-I droop control is introduced in Chapter 2. In this control approach, each DER is equipped with a GPS receiver, which produces a pulse at frequency of 1Hz (1PPS). Since all GPS receivers are locked to atomic clocks of the GPS satellites, the 1PPS signal can be utilized to synchronize the time reference of the DER units. Using the common time reference and fixing the frequency at the nominal value, all of the units can share a common synchronous rotating reference frame (SRRF). Furthermore, proportional load sharing is achieved by drooping the d and q axis components of the reference voltage with respect to the d and q axis components of current, respectively. The proposed scheme not only circumvents the issue of frequency fluctuations but also is in accordance with the fast dynamics of inverter-based DER units and resistive nature of the networks in islanded MGs. The V-I droop scheme, in its basic form, relies on availability of GPS signals at each of the DER units. With the intention of improving the MG robustness with respect to GPS signal failure, a new control strategy based on V-I droop concept is presented Chapter 3. In this method, an adaptive reactive power-frequency droop scheme is used as a backup for the V-I droop controller to ensure synchronization in case of a GPS signal failure. Droop control schemes in general, and the proposed V-I droop strategy in particular are characterized by non-ideal sharing of current among the DER units due to the variations of voltage along the MGs. In order to improve the sharing accuracy of the V-I droop scheme iv while regulating the average voltage at the nominal value, a new distributed secondary control method based on consensus protocol is proposed in Chapter 4. In this method, the daxis droop characteristics is altered so as to regulate the average microgrid voltage to the rated value but also guarantee proper sharing of active power among the DERs. Additionally, the q-axis component of voltage is adjusted to perform proper sharing of current. Generally, DERs might be supplied from different energy sources, including renewables and storage systems. The intermittency of renewable energy resources on one hand and the limited capacity of the energy storage systems on the other hand, necessitate modification of droop characteristics based on an energy management plan. In Chapter 5, a novel distributed secondary control strategy is introduced for power management of integrated photovoltaicbattery DER units in islanded MGs. The distributed secondary controllers are coordinated based on a leader-follower framework, where the leader restores the MG voltage to the rated value and the followers pursue energy management. Unbalanced and nonlinear loads, which are quite common in MGs, adversely affect the power quality and sharing accuracy. In order to mitigate those issues, two new solutions are proposed in this thesis. In the first approach (Chapter 6), a new supplementary droop control scheme is added to the V-I droop controller to reduce the voltage unbalance while preventing current and power overload under unbalanced loading conditions. In the second approach (Chapter 7), a hierarchical control scheme, consisting of primary (modified V-I droop) and distributed secondary control levels is introduced to mitigate harmonic distortions and prevent overcurrent stresses under nonlinear and unbalanced loading conditions. Finally, the conclusions and possible future work are addressed in Chapter 8

    Planning assistance for the 30/20 GHz program, volume 1

    Get PDF
    Functional requirements for the 30/20 GHz communication system, planning assistance for the 30/20 GHz program, and a review of specified conceptual designs and recommendations are provided

    Space-Based Information Infrastructure Architecture for Broadband Services

    Get PDF
    This study addressed four tasks: (1) identify satellite-addressable information infrastructure markets; (2) perform network analysis for space-based information infrastructure; (3) develop conceptual architectures; and (4) economic assessment of architectures. The report concludes that satellites will have a major role in the national and global information infrastructure, requiring seamless integration between terrestrial and satellite networks. The proposed LEO, MEO, and GEO satellite systems have satellite characteristics that vary widely. They include delay, delay variations, poorer link quality and beam/satellite handover. The barriers against seamless interoperability between satellite and terrestrial networks are discussed. These barriers are the lack of compatible parameters, standards and protocols, which are presently being evaluated and reduced

    Autonomous Recovery Of Reconfigurable Logic Devices Using Priority Escalation Of Slack

    Get PDF
    Field Programmable Gate Array (FPGA) devices offer a suitable platform for survivable hardware architectures in mission-critical systems. In this dissertation, active dynamic redundancy-based fault-handling techniques are proposed which exploit the dynamic partial reconfiguration capability of SRAM-based FPGAs. Self-adaptation is realized by employing reconfiguration in detection, diagnosis, and recovery phases. To extend these concepts to semiconductor aging and process variation in the deep submicron era, resilient adaptable processing systems are sought to maintain quality and throughput requirements despite the vulnerabilities of the underlying computational devices. A new approach to autonomous fault-handling which addresses these goals is developed using only a uniplex hardware arrangement. It operates by observing a health metric to achieve Fault Demotion using Recon- figurable Slack (FaDReS). Here an autonomous fault isolation scheme is employed which neither requires test vectors nor suspends the computational throughput, but instead observes the value of a health metric based on runtime input. The deterministic flow of the fault isolation scheme guarantees success in a bounded number of reconfigurations of the FPGA fabric. FaDReS is then extended to the Priority Using Resource Escalation (PURE) online redundancy scheme which considers fault-isolation latency and throughput trade-offs under a dynamic spare arrangement. While deep-submicron designs introduce new challenges, use of adaptive techniques are seen to provide several promising avenues for improving resilience. The scheme developed is demonstrated by hardware design of various signal processing circuits and their implementation on a Xilinx Virtex-4 FPGA device. These include a Discrete Cosine Transform (DCT) core, Motion Estimation (ME) engine, Finite Impulse Response (FIR) Filter, Support Vector Machine (SVM), and Advanced Encryption Standard (AES) blocks in addition to MCNC benchmark circuits. A iii significant reduction in power consumption is achieved ranging from 83% for low motion-activity scenes to 12.5% for high motion activity video scenes in a novel ME engine configuration. For a typical benchmark video sequence, PURE is shown to maintain a PSNR baseline near 32dB. The diagnosability, reconfiguration latency, and resource overhead of each approach is analyzed. Compared to previous alternatives, PURE maintains a PSNR within a difference of 4.02dB to 6.67dB from the fault-free baseline by escalating healthy resources to higher-priority signal processing functions. The results indicate the benefits of priority-aware resiliency over conventional redundancy approaches in terms of fault-recovery, power consumption, and resource-area requirements. Together, these provide a broad range of strategies to achieve autonomous recovery of reconfigurable logic devices under a variety of constraints, operating conditions, and optimization criteria

    Synchrophasor-based predictive control considering optimal phasor measurement unit placements methods

    Get PDF
    A blackout is the total collapse of an electric power grid, due to the inability to balance load demand and power generation. Blackouts generally develop from a series of unattended voltage stability problems, stemming from a combination of human and operational errors, and may have fatal consequences. The report on the blackout incident of August 14 2003, which affected parts of the United States and Canada, particularly emphasised the need for improved wide area monitoring of the grid. In the United Kingdom, the recent blackout of August 9 2019 has reinforced the need for increased grid visibility and data recording. These have led to an ever-increasing interest in a family of measurement devices known as Wide Area Monitoring Systems (WAMS). The most popular device in this family is the Phasor Measurement Unit (PMU), which report voltage and current phasors at rates up to 60 samples/second. PMUs may be used to monitor all or part of the grid to prevent future blackouts with timely control actions. The goal is to ’See it fast: Keep it calm’. Wide-area monitoring enhances the possibility of visualizing the electric grid as a single system. This has led to the extension of the application of WAMS from mainly monitoring to wide-area control in relatively recent research efforts. This work explores how predictive control technique may be used to automate the control of power systems voltages at secondary level using an array of synchrophasors. The intuition is to develop a model-free (or synchrophasor-based) control algorithm, which reduces, as much as possible, the need for human interventions in the mitigation of voltage problems, and is fast enough to be applied online in real-time. Although model-based techniques can be applied online, they may not be fast enough for real-time applications. In addition, this method may depend on components’ parameters, which may not be available in practice. The work is split into two parts. First, novel WAMS deployment algorithms —using multi-variable, multi-objective optimization set-ups, which return optimal placement solutions —are presented. Formulations are described for multi-stage deployments given a limited budget and for application-focused cases. Practical issues which may develop are anticipated and addressed. The formulations were shown to return optimal solutions with qualitative placement specifications. In the second part, methods of realizing models from input-output relationships are developed and described. The first involved a method numerical derivatives based on data that are sampled at PMU rates. This may be seen as a viable alternative to the use of trajectory sensitivity, especially for real-time control design. In the second, subspace algorithm are used to realise models. The process is comprehensively described for secondary voltage regulation in normal and emergency situations. The approach is demonstrated on a number of IEEE test cases and the controller’s performance were found to be satisfactory for non-viable voltage regulations. This research work is particularly relevant in a number of ways. Chief among these is that voltage control problems may be handled in real-time without a knowledge of the model parameters. The model-free approach particularly desired since increasing integration of renewable energy sources means that the electric grid is becoming increasingly complex. Another is that the placement algorithms describe all various practical issues around the measurement-based design, which utilities may found useful, especially when they wish to address budget limitation and device compatibility issues

    Simulation and analytical performance studies of generic atm switch fabrics.

    Get PDF
    As technology improves exciting new services such as video phone become possible and economically viable but their deployment is hampered by the inability of the present networks to carry them. The long term vision is to have a single network able to carry all present and future services. Asynchronous Transfer Mode, ATM, is the versatile new packet -based switching and multiplexing technique proposed for the single network. Interest in ATM is currently high as both industrial and academic institutions strive to understand more about the technique. Using both simulation and analysis, this research has investigated how the performance of ATM switches is affected by architectural variations in the switch fabric design and how the stochastic nature of ATM affects the timing of constant bit rate services. As a result the research has contributed new ATM switch performance data, a general purpose ATM switch simulator and analytic models that further research may utilise and has uncovered a significant timing problem of the ATM technique. The thesis will also be of interest and assistance to anyone planning on using simulation as a research tool to model an ATM switch
    • …
    corecore