630 research outputs found

    A new mini-navigation tool allows accurate component placement during anterior total hip arthroplasty.

    Get PDF
    Introduction: Computer-assisted navigation systems have been explored in total hip arthroplasty (THA) to improve component positioning. While these systems traditionally rely on anterior pelvic plane registration, variances in soft tissue thickness overlying anatomical landmarks can lead to registration error, and the supine coronal plane has instead been proposed. The purpose of this study was to evaluate the accuracy of a novel navigation tool, using registration of the anterior pelvic plane or supine coronal plane during simulated anterior THA. Methods: Measurements regarding the acetabular component position, and changes in leg length and offset were recorded. Benchtop phantoms and target measurement values commonly seen in surgery were used for analysis. Measurements for anteversion and inclination, and changes in leg length and offset were recorded by the navigation tool and compared with the known target value of the simulation. Pearson\u27s Results: The device accurately measured cup position and leg length measurements to within 1° and 1 mm of the known target values, respectively. Across all simulations, there was a strong, positive relationship between values obtained by the device and the known target values ( Conclusion: The preliminary findings of this study suggest that the novel navigation tool tested is a potentially viable tool to improve the accuracy of component placement during THA using the anterior approach

    Genauigkeit eines bildfreien Navigationssystemes für die Hüftpfannenimplantation – eine anatomische Studie

    Get PDF
    The position of the acetabular cup is of decisive importance for. the function of a total hip replacement (THR). Using the conventional surgical technique, correct placement of the cup often fails due to a lack of information about pelvic tilt. With CT-based and fluoroscopically-assisted navigation procedures the accuracy of implantation has been significantly improved. However, additional radiation exposure, high cost and the increased time requirement have hampered the acceptance of these techniques. The present anatomical study evaluates the accuracy of an alternative procedure-image-free navigation. This method requires little extra effort, does not substantially delay surgery, and needs no additional imaging. Press-fit cups were implanted in 10 human cadaveric hips with the help of the image-free navigation system, and the position of the cups was checked intraoperatively with a CT-based navigation system and postoperatively by computed tomography. All cups were implanted within the targeted safe zone with an average inclination of 44degrees (range 40degrees-48degrees, SABW 2.7degrees) and an average anteversion of 18degrees (range 12-24degrees, SABW 4.1degrees). Analysis of accuracy of the image-free navigation software revealed only a small, clinically tolerable deviation in cup anteversion and cup inclination in comparison with the CT-based navigation system and the post operative CT scans. The evaluated image-free navigation system appears to be a practicable and reliable alternative to the computer-assisted implantation of acetabular cups in total hip arthroplasty

    Computer-assisted placement technique in hip resurfacing arthroplasty: improvement in accuracy?

    Get PDF
    Freehand positioning of the femoral drill guide is difficult during hip resurfacing and the surgeon is often unsure of the implant position achieved peroperatively. The purpose of this study was to find out whether, by using a navigation system, acetabular and femoral component positioning could be made easier and more precise. Eighteen patients operated on by the same surgeon were matched by sex, age, BMI, diagnosis and ASA score (nine patients with computer assistance, nine with the regular ancillary). Pre-operative planning was done on standard AP and axial radiographs with CT scan views for the computer-assisted operations. The final position of implants was evaluated by the same radiographs for all patients. The follow-up was at least 1year. No difference between both groups in terms of femoral component position was observed (p > 0.05). There was also no difference in femoral notching. A trend for a better cup position was observed for the navigated hips, especially for cup anteversion. There was no additional operating time for the navigated hips. Hip navigation for resurfacing surgery may allow improved visualisation and hip implant positioning, but its advantage probably will be more obvious with mini-incisions than with regular incision surger

    Accuracy of acetabular cup positioning using imageless navigation

    Get PDF
    Background: Correct placement of the acetabular cup is a crucial step in total hip replacement to achieve a satisfactory result and remains a challenge with free-hand techniques. Imageless navigation may provide a viable alternative to free-hand technique and improve placement significantly. The purpose of this project was to assess and validate intra-operative placement values for both inclination and anteversion as displayed by an imageless navigation system to post-operative measurement of cup position using high resolution CT scans

    The accuracy of free-hand cup positioning: a CT based measurement in a South Indian hospital

    Get PDF
    Background: In total hip arthroplasty, the restoration of normal hip center in acetabular reconstruction encourages the normal bio mechanics. The impingement, dislocation, and implant wear have increased the interest in accurate component placement in arthroplasty. This study is to determine the accuracy of the free hand technique in the acetabular cup placement in relation to native acetabulam using CT scan images.Methods: This study was done in the Coimbatore Medical College and Hospital from June 2015 to March 2016. Twenty patients who have undergone total hip replacements were subjected to CT scan of pelvis preoperatively and postoperatively. The acetabular cup version and the inclination were measured and analyzed statistically.Results: The mean acetabular version was 17.5◦±6.5◦ and the inclination was 46.6◦±9.3◦ pre operatively. Post operatively the mean acetabular version was 26.3◦±17.3◦ and the inclination was 41.7◦±10.9◦. With reference to the component version it ranged from 12.5˚ of retroversion to 62.5˚ anteversion with a mean of 26.3◦±17.3◦. The component inclination ranged from 15.6◦ to 58.4◦ with a mean of 41.7◦±10.9◦. On combining component version and inclination, only (50%) was within the safe zone.Conclusions: Based on the CT finding acetabular version and inclination differs from individual to individual. During acetabular cup placement in total hip arthroplasty using free hand technique, our study shows that that inclination is better achieved and the anteversion is over targeted in most of the cases

    Recent trends, technical concepts and components of computer-assisted orthopedic surgery systems: A comprehensive review

    Get PDF
    Computer-assisted orthopedic surgery (CAOS) systems have become one of the most important and challenging types of system in clinical orthopedics, as they enable precise treatment of musculoskeletal diseases, employing modern clinical navigation systems and surgical tools. This paper brings a comprehensive review of recent trends and possibilities of CAOS systems. There are three types of the surgical planning systems, including: systems based on the volumetric images (computer tomography (CT), magnetic resonance imaging (MRI) or ultrasound images), further systems utilize either 2D or 3D fluoroscopic images, and the last one utilizes the kinetic information about the joints and morphological information about the target bones. This complex review is focused on three fundamental aspects of CAOS systems: their essential components, types of CAOS systems, and mechanical tools used in CAOS systems. In this review, we also outline the possibilities for using ultrasound computer-assisted orthopedic surgery (UCAOS) systems as an alternative to conventionally used CAOS systems.Web of Science1923art. no. 519

    Poor accuracy of freehand cup positioning during total hip arthroplasty

    Get PDF
    Several studies have demonstrated a correlation between the acetabular cup position and the risk of dislocation, wear and range of motion after total hip arthroplasty. The present study was designed to evaluate the accuracy of the surgeon’s estimated position of the cup after freehand placement in total hip replacement. Peroperative estimated abduction and anteversion of 200 acetabular components (placed by three orthopaedic surgeons and nine residents) were compared with measured outcomes (according to Pradhan) on postoperative radiographs. Cups were placed in 49.7° (SD 6.7) of abduction and 16.0° (SD 8.1) of anteversion. Estimation of placement was 46.3° (SD 4.3) of abduction and 14.6° (SD 5.9) of anteversion. Of more interest is the fact that for the orthopaedic surgeons the mean inaccuracy of estimation was 4.1° (SD 3.9) for abduction and 5.2° (SD 4.5) for anteversion and for their residents this was respectively, 6.3° (SD 4.6) and 5.7° (SD 5.0). Significant differences were found between orthopaedic surgeons and residents for inaccuracy of estimation for abduction, not for anteversion. Body mass index, sex, (un)cemented fixation and surgical approach (anterolateral or posterolateral) were not significant factors. Based upon the inaccuracy of estimation, the group’s chance on future cup placement within Lewinnek’s safe zone (5–25° anteversion and 30–50° abduction) is 82.7 and 85.2% for anteversion and abduction separately. When both parameters are combined, the chance of accurate placement is only 70.5%. The chance of placement of the acetabular component within 5° of an intended position, for both abduction and anteversion is 21.5% this percentage decreases to just 2.9% when the tolerated error is 1°. There is a tendency to underestimate both abduction and anteversion. Orthopaedic surgeons are superior to their residents in estimating abduction of the acetabular component. The results of this study indicate that freehand placement of the acetabular component is not a reliable method

    The Top Three Burning Questions in Total Hip Arthroplasty.

    Get PDF
    Total hip arthroplasty (THA) for end-stage osteoarthritis is one of the most effective surgical treatments in medicine. Impressive outcomes have been well documented in the literature with patients gaining ambulation and recovery of hip joint function. Nevertheless, there are still debatable issues and controversies that the orthopedic community has not been able to provide a definitive answer for. This review is focused on the current three most debatable issues surrounding the THA procedure: (1) new cutting-edge technology, (2) spinopelvic mobility, and (3) fast-track protocols. The scope of the herein narrative review is to analyze the debatable issues surrounding the three aforementioned topics and conclude the best contemporary clinical approaches regarding each issue

    Minimally invasive computer-navigated total hip arthroplasty, following the concept of femur first and combined anteversion: design of a blinded randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Impingement can be a serious complication after total hip arthroplasty (THA), and is one of the major causes of postoperative pain, dislocation, aseptic loosening, and implant breakage. Minimally invasive THA and computer-navigated surgery were introduced several years ago. We have developed a novel, computer-assisted operation method for THA following the concept of "femur first"/"combined anteversion", which incorporates various aspects of performing a functional optimization of the cup position, and comprehensively addresses range of motion (ROM) as well as cup containment and alignment parameters. Hence, the purpose of this study is to assess whether the artificial joint's ROM can be improved by this computer-assisted operation method. Second, the clinical and radiological outcome will be evaluated.</p> <p>Methods/Design</p> <p>A registered patient- and observer-blinded randomized controlled trial will be conducted. Patients between the ages of 50 and 75 admitted for primary unilateral THA will be included. Patients will be randomly allocated to either receive minimally invasive computer-navigated "femur first" THA or the conventional minimally invasive THA procedure. Self-reported functional status and health-related quality of life (questionnaires) will be assessed both preoperatively and postoperatively. Perioperative complications will be registered. Radiographic evaluation will take place up to 6 weeks postoperatively with a computed tomography (CT) scan. Component position will be evaluated by an independent external institute on a 3D reconstruction of the femur/pelvis using image-processing software. Postoperative ROM will be calculated by an algorithm which automatically determines bony and prosthetic impingements.</p> <p>Discussion</p> <p>In the past, computer navigation has improved the accuracy of component positioning. So far, there are only few objective data quantifying the risks and benefits of computer navigated THA. Therefore, this study has been designed to compare minimally invasive computer-navigated "femur first" THA with a conventional technique for minimally invasive THA. The results of this trial will be presented as soon as they become available.</p> <p>Trial registration number</p> <p>DRKS00000739</p
    corecore