    Medical image computing and computer-aided medical interventions applied to soft tissues. Work in progress in urology

    Full text link
    Until recently, Computer-Aided Medical Interventions (CAMI) and Medical Robotics have focused on rigid and non deformable anatomical structures. Nowadays, special attention is paid to soft tissues, raising complex issues due to their mobility and deformation. Mini-invasive digestive surgery was probably one of the first fields where soft tissues were handled through the development of simulators, tracking of anatomical structures and specific assistance robots. However, other clinical domains, for instance urology, are concerned. Indeed, laparoscopic surgery, new tumour destruction techniques (e.g. HIFU, radiofrequency, or cryoablation), increasingly early detection of cancer, and use of interventional and diagnostic imaging modalities, recently opened new challenges to the urologist and scientists involved in CAMI. This resulted in the last five years in a very significant increase of research and developments of computer-aided urology systems. In this paper, we propose a description of the main problems related to computer-aided diagnostic and therapy of soft tissues and give a survey of the different types of assistance offered to the urologist: robotization, image fusion, surgical navigation. Both research projects and operational industrial systems are discussed

    Accuracy of multiparametric magnetic resonance imaging to detect significant prostate cancer and index lesion location

    Get PDF
    Background: Multiparametric magnetic resonance imaging (mpMRI) of the prostate appears to improve prostate cancer detection, but studies comparing mpMRI to histopathology at the time of radical prostatectomy (RP) are lacking. This retrospective study determined the accuracy of mpMRI predicting Gleason score and index lesion location at the time of RP, the current gold standard for diagnosis. Methods: Between April 2013 and April 2016, a database of all men aged more than 40 years who underwent RP after positive transrectal ultrasound biopsy by an experienced urological surgeon was collated at a single regional centre. This was cross‐referenced with a database of all men who had mpMRIs performed at a single centre and reported according to Prostate Imaging Reporting and Data System (PI‐RADS version 1) during this period to generate a sample size of 64 men. A Spearman\u27s rho test was utilized to calculate correlation. Results: Median age of patients was 64 years, the median prostate‐specific antigen at RP was 6.22 ng/mL. mpMRI was positive (≥PI‐RADS 3) in 85.9% of patients who underwent RP. More than 92% of participants had Gleason ≥7 disease. A positive relationship between mpMRI prostate PI‐RADS score and RP cancer volume was demonstrated. An anatomical location correlation calculated in octants was found to be 89.1% accurate. Conclusion: mpMRI accurately detects prostate cancer location and severity when compared with gold standard histopathology at the time of RP. It thus has an important role in planning for future prostate biopsy and cancer treatment

    Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies

    Get PDF
    Item does not contain fulltextOBJECTIVES: To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. METHODS: A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. RESULTS: The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. CONCLUSIONS: Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique - currently - more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures.01 februari 201

    Needle and Biopsy Robots: a Review

    Get PDF
    Purpose of the review Robotics is a rapidly advancing field, and its introduction in healthcare can have a multitude of benefits for clinical practice. Especially, applications depending on the radiologist\u2019s accuracy and precision, such as percutaneous interventions, may profit. This paper provides an overview of recent robot-assisted percutaneous solutions. Recent findings Percutaneous interventions are relatively simple and the quality of the procedure increases a lot by introducing robotics due to the improved accuracy and precision. The success of the procedure is heavily dependent on the ability to merge pre- and intraoperative images, as an accurate estimation of the current target location allows to exploit the robot\u2019s capabilities. Summary Despite much research, the application of robotics in some branches of healthcare is not commonplace yet. Recent advances in percutaneous robotic solutions and imaging are highlighted, as they will pave the way to more widespread implementation of robotics in clinical practic

    Increasing the precision of the biopsy with robots: two case studies

    Get PDF
    Robotics is a rapidly advancing field and its introduction in healthcare can have a multitude of benefits for clinical practice. Especially applications depending on the radiologist’s accuracy and precision, such as percutaneous interventions, may profit. Percutaneous interventions are relatively simple and the quality of the procedure increases a lot by introducing robotics due to the improved accuracy and precision. This paper provides the description of two robotic systems for percutaneous interventions: breast biopsy and prostate biopsy. The systems presented here are complete prototypes in an advanced state ready to be tested in clinical practice.https://youtu.be/KZxfRtg0afg https://www.youtube.com/watch?v=AB3Qa6LyHP

    A Pneumatic Driven MRI-Guided Robot System for Prostate Interventions

    Get PDF
    Under the guidance of high-resolution Magnetic Resonance Imaging (MRI), robotic devices offer a great advantage for prostate intervention. This paper presents an MR-safe robot, where a needle is attached to the needle guide to obtain prostate biopsies during surgeries. The robot is powered by three actuators, two of them are customized to function as a work plane that allows the needle to move horizontally and vertically, and the third actuator controls the rotation of the work plane, allowing the needle to be inserted into the prostate from different directions. All the actuators are pneumatically actuated to allow them to work in a Magnetic Resonance (MR) environment. The kinematics and mechanism of the robot are analyzed. A user interface developed using LabView is created to calculate the target position and generate a control signal for the valves. In the open-air test, the needle can reach the target with an accuracy of 1.3 mm. The signal-to-noise ratio (SNR) variation was measured below 5% under a 3T MR scanner

    Medical robots for MRI guided diagnosis and therapy

    No full text
    Magnetic Resonance Imaging (MRI) provides the capability of imaging tissue with fine resolution and superior soft tissue contrast, when compared with conventional ultrasound and CT imaging, which makes it an important tool for clinicians to perform more accurate diagnosis and image guided therapy. Medical robotic devices combining the high resolution anatomical images with real-time navigation, are ideal for precise and repeatable interventions. Despite these advantages, the MR environment imposes constraints on mechatronic devices operating within it. This thesis presents a study on the design and development of robotic systems for particular MR interventions, in which the issue of testing the MR compatibility of mechatronic components, actuation control, kinematics and workspace analysis, and mechanical and electrical design of the robot have been investigated. Two types of robotic systems have therefore been developed and evaluated along the above aspects. (i) A device for MR guided transrectal prostate biopsy: The system was designed from components which are proven to be MR compatible, actuated by pneumatic motors and ultrasonic motors, and tracked by optical position sensors and ducial markers. Clinical trials have been performed with the device on three patients, and the results reported have demonstrated its capability to perform needle positioning under MR guidance, with a procedure time of around 40mins and with no compromised image quality, which achieved our system speci cations. (ii) Limb positioning devices to facilitate the magic angle effect for diagnosis of tendinous injuries: Two systems were designed particularly for lower and upper limb positioning, which are actuated and tracked by the similar methods as the first device. A group of volunteers were recruited to conduct tests to verify the functionality of the systems. The results demonstrate the clear enhancement of the image quality with an increase in signal intensity up to 24 times in the tendon tissue caused by the magic angle effect, showing the feasibility of the proposed devices to be applied in clinical diagnosis

    Prostate biopsies assisted by comanipulated probe-holder: first in man

    No full text
    International audiencePurpose: a comanipulator for assisting endorectal prostate biopsies is evaluated through a first-in man clinical trial. This lightweight system, based on conventional robotic components, possesses 6 degrees of freedom. It uses 3 electric motors and 3 brakes. It features a free mode, where its low friction and inertia allow for natural manipulation of the probe and a locked mode, exhibiting both a very low stiffness and a high steady state precision. Methods: Clinical trials focusing on the free mode and the locked mode of the robot are presented. The objective is to evaluate the practical usability and performance of the robot during clinical procedures. A research protocol for a prospective randomized clinical trial has been designed. Its specific goal is to compare the accuracy of biopsies performed with and without the assistance of the comanipulator. Results:The accuracy is compared between biopsies performed with and without the assistance of the comanipulator, across the 10 first patients included in the trial. Results show a statistically significant increase of the precision.. This work is partially funded french state funds managed by the ANR within the Investissements d'Avenir programme (Labex CAMI) under reference ANR-11-LABX-0004. 2 Marie-Aude Vitrani et al

    MRI robot for prostate focal laser ablation : An ex vivo study in human prostate

    Get PDF
    Purpose: A novel grid-template-mimicking MR-compatible robot was developed for in-gantry MRI-guided focal laser ablation of prostate cancer. Method: A substantially compact robot was designed and prototyped to meet in-gantry lithotomy ergonomics and allow for accommodation in the perineum. The controller software was reconfigured and integrated with the custom-designed navigation and multi-focal ablation software. Three experiments were conducted: (1) free space accuracy test; (2) phantom study under computed tomography (CT) guidance for image-guided accuracy test and overall workflow; and (3) magnetic resonance imaging (MRI)-guided focal laser ablation of an ex vivo prostate. The free space accuracy study included five targets that were selected across the workspace. The robot was then commanded five times to each target. The phantom study used a gel phantom made with color changing thermos-chromic ink, and four spherical metal fiducials were deployed with the robot. Then, laser ablation was applied, and the phantom was sliced for gross observation. For an MR-guided ex vivo test, a prostate from a donor who died of prostate cancer was obtained and multi-focally ablated using the system within the MRI gantry. The tissue was sliced after ablation for validation. Results: free-space accuracy was 0.38 ± 0.27 mm. The overall system targeting accuracy under CT guidance (including robot, registration, and insertion error) was 2.17 ± 0.47 mm. The planned ablation zone was successfully covered in both acrylamide gel phantom and in human prostate tissue. Conclusions: The new robot can accurately facilitate fiber targeting for MR-guided focal laser ablation of targetable prostate cancer