134,668 research outputs found
Numerical simulation of transient moisture and temperature distribution in polycarbonate and aluminum electronic enclosures
The challenge of developing a reliable electronic product requires huge amounts of resources and knowledge. Temperature and thermal features directly affect the life of electronic products. Furthermore, moisture can be damaging for electronic components. Nowadays, computational fluid dynamics (CFD) analysis has been proven as a useful tool to exploit the detailed and visualized information about the fluid flows; and hence it can be helpful for predicting local climate inside the electronic enclosures. In this study, the temperature and moisture distributions inside an idealized electronic enclosure with some heat producing components are investigated. It is shown how the enclosure material can influence local climate inside the enclosure using transient numerical simulations. The effect of heat transfer coefficient and wall thickness of the enclosure is also investigated. The enclosure material and the heat transfer coefficient of the enclosure with the environment are found to be influential on the mean temperature and relative humidity; however, the significance of their effects are not the same at different levels. Natural convection plays a key role in RH and temperature distribution
EHV-1 Pathogenesis: Current in vitro Models and Future Perspectives
Primary infection and pathogenesis of equine herpesvirus type 1 (EHV-1) require an intricate interaction of virus with the mucosal epithelium, mononuclear cells and the vascular endothelium. Studies on EHV-1 have been facilitated by the development of different in vitro models that recapitulate the in vivo tissue complexity. The available in vitro assays can be categorized into (i) models mimicking the epithelium-peripheral blood mononuclear cell (PBMC) interaction, which include ex vivo mucosal (nasal and vaginal) explants and equine respiratory epithelial cells (EREC) cultures; and (ii) PBMC-endothelium mimicking models, including flow chamber and contact assays. These in vitro models have proven their worth in attempts to recapitulate the in vivo architecture and complexity, produce data relevant to natural host infection, and reduce animal use due to in vivo experiments. Although horse models are still needed for certain experiments, e.g., EHV-1 myeloencephalopathy or vaccination studies, available in vitro models can be used to obtain highly valuable data on virus-host tissue interactions. Microfluidic based 3D culture system (e.g., horse-on-a-chip) could be a potential upgraded version of these in vitro models for future research
Audio-visual Rhetoric: Visualizing the Pattern Language of Film
Audio-visual Rhetoric is a knowledge domain for designers in theory and practice that is valid for all communicative actions through media that aim for persuasion. Within this domain, we introduce a framework for media analysis. We developed an Audio-Visual Pattern (AVP) language for film that is visualized within a notation system. This system shows auditory and visual parameters in order to reveal film’s rhetorical structure. We discuss related theories from pattern language and rhetoric and apply the AVP method to analyze 10 commercials.
Keywords:
Pattern Language, Film Analysis, Rhetoric, Emotion, Persuasion, Design Research</p
Wearable proximity sensors for monitoring a mass casualty incident exercise: a feasibility study
Over the past several decades, naturally occurring and man-made mass casualty
incidents (MCI) have increased in frequency and number, worldwide. To test the
impact of such event on medical resources, simulations can provide a safe,
controlled setting while replicating the chaotic environment typical of an
actual disaster. A standardised method to collect and analyse data from mass
casualty exercises is needed, in order to assess preparedness and performance
of the healthcare staff involved. We report on the use of wearable proximity
sensors to measure proximity events during a MCI simulation. We investigated
the interactions between medical staff and patients, to evaluate the time
dedicated by the medical staff with respect to the severity of the injury of
the victims depending on the roles. We estimated the presence of the patients
in the different spaces of the field hospital, in order to study the patients'
flow. Data were obtained and collected through the deployment of wearable
proximity sensors during a mass casualty incident functional exercise. The
scenario included two areas: the accident site and the Advanced Medical Post
(AMP), and the exercise lasted 3 hours. A total of 238 participants simulating
medical staff and victims were involved. Each participant wore a proximity
sensor and 30 fixed devices were placed in the field hospital. The contact
networks show a heterogeneous distribution of the cumulative time spent in
proximity by participants. We obtained contact matrices based on cumulative
time spent in proximity between victims and the rescuers. Our results showed
that the time spent in proximity by the healthcare teams with the victims is
related to the severity of the patient's injury. The analysis of patients' flow
showed that the presence of patients in the rooms of the hospital is consistent
with triage code and diagnosis, and no obvious bottlenecks were found
Rapid Fabrication of Custom Microfluidic Devices for Research and Educational Applications
Microfluidic devices allow for the manipulation of fluids, particles, cells, micro-sized organs or organisms in channels ranging from the nano to submillimeter scales. A rapid increase in the use of this technology in the biological sciences has prompted a need for methods that are accessible to a wide range of research groups. Current fabrication standards, such as PDMS bonding, require expensive and time consuming lithographic and bonding techniques. A viable alternative is the use of equipment and materials that are easily affordable, require minimal expertise and allow for the rapid iteration of designs. In this work we describe a protocol for designing and producing PET-laminates (PETLs), microfluidic devices that are inexpensive, easy to fabricate, and consume significantly less time to generate than other approaches to microfluidics technology. They consist of thermally bonded film sheets, in which channels and other features are defined using a craft cutter. PETLs solve field-specific technical challenges while dramatically reducing obstacles to adoption. This approach facilitates the accessibility of microfluidics devices in both research and educational settings, providing a reliable platform for new methods of inquiry
Gap-junctional coupling between neutrophils and endothelial cells
Communication between leukocytes and endothelial cells is crucial for inflammatory reactions. Paracrine cross-talk and outside-in signaling (via adhesion molecules) have been characterized as communication pathways to date. As leukocytes and endothelial cells express connexins, we considered intercellular communication via gap junctions an intriguing additional concept. We found that gap-junctional coupling between neutrophils and endothelium occurred in a time-dependent, bidirectional manner and was facilitated by adhesion. After blockade of connexins, transmigration of neutrophils through the endothelial layer was enhanced, and the barrier function of cell monolayers was reduced during transmigration. Tumor necrosis factor α decreased coupling. In the presence of connexins, transmigration of neutrophils did not alter permeability. Thus, neutrophils couple to endothelium via gap junctions, functionally modulating transmigration and leakiness. Gapjunctional coupling may be a novel way of leukocyte-
endothelial communication
Microfluidic flow chambers using reconstituted blood to model hemostasis and platelet transfusion in vitro
Blood platelets prepared for transfusion gradually lose hemostatic function during storage. Platelet function can be investigated using a variety of (indirect) in vitro experiments, but none of these is as comprehensive as microfluidic flow chambers. In this protocol, the reconstitution of thrombocytopenic fresh blood with stored blood bank platelets is used to simulate platelet transfusion. Next, the reconstituted sample is perfused in microfluidic flow chambers which mimic hemostasis on exposed subendothelial matrix proteins. Effects of blood donation, transport, component separation, storage and pathogen inactivation can be measured in paired experimental designs. This allows reliable comparison of the impact every manipulation in blood component preparation has on hemostasis. Our results demonstrate the impact of temperature cycling, shear rates, platelet concentration and storage duration on platelet function. In conclusion, this protocol analyzes the function of blood bank platelets and this ultimately aids in optimization of the processing chain including phlebotomy, transport, component preparation, storage and transfusion
Recommended from our members
Visual support for ontology learning: an experience report
Ontology learning methods aim to automate ontology
construction. They are complex methods involving several
elements such as documents, terms and concepts. During the development of an ontology learning method, as well as during its deployment, several situations occur where
understanding the relations between these elements is crucial. Our hypothesis is that visual techniques can be used to aid this understanding. To support this claim, we present a set of such complex situations and describe the visual solutions that we developed to support them
Treatment of Ligament Constructs with Exercise-conditioned Serum: A Translational Tissue Engineering Model.
In vitro experiments are essential to understand biological mechanisms; however, the gap between monolayer tissue culture and human physiology is large, and translation of findings is often poor. Thus, there is ample opportunity for alternative experimental approaches. Here we present an approach in which human cells are isolated from human anterior cruciate ligament tissue remnants, expanded in culture, and used to form engineered ligaments. Exercise alters the biochemical milieu in the blood such that the function of many tissues, organs and bodily processes are improved. In this experiment, ligament construct culture media was supplemented with experimental human serum that has been 'conditioned' by exercise. Thus the intervention is more biologically relevant since an experimental tissue is exposed to the full endogenous biochemical milieu, including binding proteins and adjunct compounds that may be altered in tandem with the activity of an unknown agent of interest. After treatment, engineered ligaments can be analyzed for mechanical function, collagen content, morphology, and cellular biochemistry. Overall, there are four major advantages versus traditional monolayer culture and animal models, of the physiological model of ligament tissue that is presented here. First, ligament constructs are three-dimensional, allowing for mechanical properties (i.e., function) such as ultimate tensile stress, maximal tensile load, and modulus, to be quantified. Second, the enthesis, the interface between boney and sinew elements, can be examined in detail and within functional context. Third, preparing media with post-exercise serum allows for the effects of the exercise-induced biochemical milieu, which is responsible for the wide range of health benefits of exercise, to be investigated in an unbiased manner. Finally, this experimental model advances scientific research in a humane and ethical manner by replacing the use of animals, a core mandate of the National Institutes of Health, the Center for Disease Control, and the Food and Drug Administration
- …