6 research outputs found

    Modern Telemetry

    Get PDF
    Telemetry is based on knowledge of various disciplines like Electronics, Measurement, Control and Communication along with their combination. This fact leads to a need of studying and understanding of these principles before the usage of Telemetry on selected problem solving. Spending time is however many times returned in form of obtained data or knowledge which telemetry system can provide. Usage of telemetry can be found in many areas from military through biomedical to real medical applications. Modern way to create a wireless sensors remotely connected to central system with artificial intelligence provide many new, sometimes unusual ways to get a knowledge about remote objects behaviour. This book is intended to present some new up to date accesses to telemetry problems solving by use of new sensors conceptions, new wireless transfer or communication techniques, data collection or processing techniques as well as several real use case scenarios describing model examples. Most of book chapters deals with many real cases of telemetry issues which can be used as a cookbooks for your own telemetry related problems

    Ameliorating integrated sensor drift and imperfections: an adaptive "neural" approach

    Get PDF

    From RF-Microsystem Technology to RF-Nanotechnology

    Get PDF
    The RF microsystem technology is believed to introduce a paradigm switch in the wireless revolution. Although only few companies are to date doing successful business with RF-MEMS, and on a case-by-case basis, important issues need yet to be addressed in order to maximize yield and performance stability and hence, outperform alternative competitive technologies (e.g. ferroelectric, SoS, SOI,…). Namely the behavior instability associated to: 1) internal stresses of the free standing thin layers (metal and/or dielectric) and 2) the mechanical contact degradation, be it ohmic or capacitive, which may occur due to low forces, on small areas, and while handling severe current densities.The investigation and understanding of these complex scenario, has been the core of theoretical and experimental investigations carried out in the framework of the research activity that will be presented here. The reported results encompass activities which go from coupled physics (multiphysics) modeling, to the development of experimental platforms intended to tackles the underlying physics of failure. Several original findings on RF-MEMS reliability in particular with respect to the major failure mechanisms such as dielectric charging, metal contact degradation and thermal induced phenomena have been obtained. The original use of advanced experimental setup (surface scanning microscopy, light interferometer profilometry) has allowed the definition of innovative methodology capable to isolate and separately tackle the different degradation phenomena under arbitrary working conditions. This has finally permitted on the one hand to shed some light on possible optimization (e.g. packaging) conditions, and on the other to explore the limits of microsystem technology down to the nanoscale. At nanoscale indeed many phenomena take place and can be exploited to either enhance conventional functionalities and performances (e.g. miniaturization, speed or frequency) or introduce new ones (e.g. ballistic transport). At nanoscale, moreover, many phenomena exhibit their most interesting properties in the RF spectrum (e.g. micromechanical resonances). Owing to the fact that today’s minimum manufacturable features have sizes comparable with the fundamental technological limits (e.g. surface roughness, metal grain size, …), the next generation of smart systems requires a switching paradigm on how new miniaturized components are conceived and fabricated. In fact endowed by superior electrical and mechanical performances, novel nanostructured materials (e.g. carbon based, as carbon nanotube (CNT) and graphene) may provide an answer to this endeavor. Extensively studied in the DC and in the optical range, the studies engaged in LAAS have been among the first to target microwave and millimiterwave transport properties in carbon-based material paving the way toward RF nanodevices. Preliminary modeling study performed on original test structures have highlighted the possibility to implement novel functionalities such as the coupling between the electromagnetic (RF) and microelectromechanical energy in vibrating CNT (toward the nanoradio) or the high speed detection based on ballistic transport in graphene three-terminal junction (TTJ). At the same time these study have contributed to identify the several challenges still laying ahead such as the development of adequate design and modeling tools (ballistic/diffusive, multiphysics and large scale factor) and practical implementation issues such as the effects of material quality and graphene-metal contact on the electrical transport. These subjects are the focus of presently on-going and future research activities and may represent a cornerstone of future wireless applications from microwave up to the THz range

    VLSI Design

    Get PDF
    This book provides some recent advances in design nanometer VLSI chips. The selected topics try to present some open problems and challenges with important topics ranging from design tools, new post-silicon devices, GPU-based parallel computing, emerging 3D integration, and antenna design. The book consists of two parts, with chapters such as: VLSI design for multi-sensor smart systems on a chip, Three-dimensional integrated circuits design for thousand-core processors, Parallel symbolic analysis of large analog circuits on GPU platforms, Algorithms for CAD tools VLSI design, A multilevel memetic algorithm for large SAT-encoded problems, etc

    Development of a 1D phased ultrasonic array for intravascular sonoporation

    Get PDF
    Error on title page – year of award is 2021.Sonoporation represents a promising approach to increase targeted drug delivery efficiency by facilitating transport of therapeutic agents to the target tissue with the use of ultrasound. However, most of the current research in sonoporation is performed with external ultrasonic transducers, which hinders the applicability of the therapeutic procedure for treatment of conditions situated deeper into the patient’s body, such as liver or intestinal tumours. This Thesis presents the development process of a miniature-sized 1-3 connectivity piezocomposite 1D phased array for intracorporeal sonoporation. The device was to be incorporated into a capsule or catheter and hence the primary design constraint was the reduced size of the piezoelectric element, which was limited to 2.5 mm in width and 12 mm in length. To meet the needs of the intended application, resonance frequencies of 1.5 MHz and 3.0 MHz were considered. A simulation framework was developed for optimization of the miniature array in relation to the peak negative pressure attained at the focus to mitigate the low power output associated with the limited device dimensions. This was implemented through a multiparametric sweep of the 1-3 piezocomposite geometry-related parameters. Devices made with PZT-5H and PMN-29%PT were evaluated. The optimization algorithm was used to determine specifications for phased array designs based on the two materials and the two resonance frequencies. The 1.5 MHz devices comprised 24 elements and the 3.0 MHz ones had 32 elements. The piezocomposites were manufactured using the dice and fill technique and electroded using a novel method of electrode deposition employing spin coating of Ag ink. Subsequently, the prototype devices were driven with a commercial array controller and characterized with a calibrated needle hydrophone in a scanning tank. Two simulation profiles based on finite element analysis and time extrapolation were developed to model the acoustic beams from the arrays, which were compared and calibrated with experimental data for focal distances between 5 mm and 10 mm and beam steering angles from 0° to 40°. The results showed that modelling could be employed reliably for therapeutic planning. Both the 1.5 MHz and the 3.0 MHz, PZT-5H arrays were tested in vitro and shown to induce and control sonoporation of a human epithelial colorectal adenocarcinoma cell layer. Finally, a 24 element, 1.5 MHz, PZT-5H array was implemented in a 40 mm long by 11 mm diameter tethered, biocompatible capsule intended for in vivo operation. The device was characterized in the scanning tank for steering angles in the range 0° to 56° and focal distances between 4.0 mm and 5.7 mm, and the measured beam profiles were correlated with the simulation framework. The capsule will be tested in future ex-vivo and in-vivo experiments on insulin absorption through porcine small bowel by means of sonoporation.Sonoporation represents a promising approach to increase targeted drug delivery efficiency by facilitating transport of therapeutic agents to the target tissue with the use of ultrasound. However, most of the current research in sonoporation is performed with external ultrasonic transducers, which hinders the applicability of the therapeutic procedure for treatment of conditions situated deeper into the patient’s body, such as liver or intestinal tumours. This Thesis presents the development process of a miniature-sized 1-3 connectivity piezocomposite 1D phased array for intracorporeal sonoporation. The device was to be incorporated into a capsule or catheter and hence the primary design constraint was the reduced size of the piezoelectric element, which was limited to 2.5 mm in width and 12 mm in length. To meet the needs of the intended application, resonance frequencies of 1.5 MHz and 3.0 MHz were considered. A simulation framework was developed for optimization of the miniature array in relation to the peak negative pressure attained at the focus to mitigate the low power output associated with the limited device dimensions. This was implemented through a multiparametric sweep of the 1-3 piezocomposite geometry-related parameters. Devices made with PZT-5H and PMN-29%PT were evaluated. The optimization algorithm was used to determine specifications for phased array designs based on the two materials and the two resonance frequencies. The 1.5 MHz devices comprised 24 elements and the 3.0 MHz ones had 32 elements. The piezocomposites were manufactured using the dice and fill technique and electroded using a novel method of electrode deposition employing spin coating of Ag ink. Subsequently, the prototype devices were driven with a commercial array controller and characterized with a calibrated needle hydrophone in a scanning tank. Two simulation profiles based on finite element analysis and time extrapolation were developed to model the acoustic beams from the arrays, which were compared and calibrated with experimental data for focal distances between 5 mm and 10 mm and beam steering angles from 0° to 40°. The results showed that modelling could be employed reliably for therapeutic planning. Both the 1.5 MHz and the 3.0 MHz, PZT-5H arrays were tested in vitro and shown to induce and control sonoporation of a human epithelial colorectal adenocarcinoma cell layer. Finally, a 24 element, 1.5 MHz, PZT-5H array was implemented in a 40 mm long by 11 mm diameter tethered, biocompatible capsule intended for in vivo operation. The device was characterized in the scanning tank for steering angles in the range 0° to 56° and focal distances between 4.0 mm and 5.7 mm, and the measured beam profiles were correlated with the simulation framework. The capsule will be tested in future ex-vivo and in-vivo experiments on insulin absorption through porcine small bowel by means of sonoporation

    Aerospace Medicine and Biology. an Annotated Bibliography. 1958-1961 Literature, Volumes VII-X, Part 2

    Get PDF
    Abstracts on aerospace medicine and biology - bibliography on environmental factors, safety and survival, personnel, pharmacology, toxicology, and life support system
    corecore