321 research outputs found

    Redundant disk arrays: Reliable, parallel secondary storage

    Get PDF
    During the past decade, advances in processor and memory technology have given rise to increases in computational performance that far outstrip increases in the performance of secondary storage technology. Coupled with emerging small-disk technology, disk arrays provide the cost, volume, and capacity of current disk subsystems, by leveraging parallelism, many times their performance. Unfortunately, arrays of small disks may have much higher failure rates than the single large disks they replace. Redundant arrays of inexpensive disks (RAID) use simple redundancy schemes to provide high data reliability. The data encoding, performance, and reliability of redundant disk arrays are investigated. Organizing redundant data into a disk array is treated as a coding problem. Among alternatives examined, codes as simple as parity are shown to effectively correct single, self-identifying disk failures

    Studies of disk arrays tolerating two disk failures and a proposal for a heterogeneous disk array

    Get PDF
    There has been an explosion in the amount of generated data in the past decade. Online access to these data is made possible by large disk arrays, especially in the RAID (Redundant Array of Independent Disks) paradigm. According to the RAID level a disk array can tolerate one or more disk failures, so that the storage subsystem can continue operating with disk failure(s). RAID 5 is a single disk failure tolerant array which dedicates the capacity of one disk to parity information. The content on the failed disk can be reconstructed on demand and written onto a spare disk. However, RAID5 does not provide enough protection for data since the data loss may occur when there is a media failure (unreadable sectors) or a second disk failure during the rebuild process. Due to the high cost of downtime in many applications, two disk failure tolerant arrays, such as RAID6 and EVENODD, have become popular. These schemes use 2/N of the capacity of the array for redundant information in order to tolerate two disk failures. RM2 is another scheme that can tolerate two disk failures, with slightly higher redundancy ratio. However, the performance of these two disk failure tolerant RAID schemes is impaired, since there are two check disks to be updated for each write request. Therefore, their performance, especially when there are disk failure(s), is of interest. In the first part of the dissertation, the operations for the RAID5, RAID6, EVENODD and RM2 schemes are described. A cost model is developed for these RAID schemes by analyzing the operations in various operating modes. This cost model offers a measure of the volume of data being transmitted, and provides adevice-independent comparison of the efficiency of these RAID schemes. Based on this cost model, the maximum throughput of a RAID scheme can be obtained given detailed disk characteristic and RAID configuration. Utilizing M/G/1 queuing model and other favorable modeling assumptions, a queuing analysis to obtain the mean read response time is described. Simulation is used to validate analytic results, as well as to evaluate the RAID systems in analytically intractable cases. The second part of this dissertation describes a new disk array architecture, namely Heterogeneous Disk Array (HDA). The HDA is motivated by a few observations of the trends in storage technology. The HDA architecture allows a disk array to have two forms of heterogeneity: (1) device heterogeneity, i.e., disks of different types can be incorporated in a single HDA; and (2) RAID level heterogeneity, i.e., various RAID schemes can coexist in the same array. The goal of this architecture is (1) utilizing the extra resource (i.e. bandwidth and capacity) introduced by new disk drives in an automated and efficient way; and (2) using appropriate RAID levels to meet the varying availability requirements for different applications. In HDA, each new object is associated with an appropriate RAID level and the allocation is carried out in a way to keep disk bandwidth and capacity utilizations balanced. Design considerations for the data structures of HDA metadata are described, followed by the actual design of the data structures and flowcharts for the most frequent operations. Then a data allocation algorithm is described in detail. Finally, the HDA architecture is prototyped based on the DASim simulation toolkit developed at NJIT and simulation results of an HDA with two RAID levels (RAID 1 and RAIDS) are presented

    A reliability model for dependent and distributed MDS disk array units

    Get PDF
    Archiving and systematic backup of large digital data generates a quick demand for multi-petabyte scale storage systems. As drive capacities continue to grow beyond the few terabytes range to address the demands of today’s cloud, the likelihood of having multiple/simultaneous disk failures became a reality. Among the main factors causing catastrophic system failures, correlated disk failures and the network bandwidth are reported to be the two common source of performance degradation. The emerging trend is to use efficient/sophisticated erasure codes (EC) equipped with multiple parities and efficient repairs in order to meet the reliability/bandwidth requirements. It is known that mean time to failure and repair rates reported by the disk manufacturers cannot capture life-cycle patterns of distributed storage systems. In this study, we develop failure models based on generalized Markov chains that can accurately capture correlated performance degradations with multiparity protection schemes based on modern maximum distance separable EC. Furthermore, we use the proposed model in a distributed storage scenario to quantify two example use cases: Primarily, the common sense that adding more parity disks are only meaningful if we have a decent decorrelation between the failure domains of storage systems and the reliability of generic multiple single-dimensional EC protected storage systems.WOS:000460728600008Scopus - Affiliation ID: 60105072Science Citation Index ExpandedQ1 - Q2ArticleUluslararası işbirliği ile yapılmayan - HAYIRMart2019YÖK - 2018-1

    RAID Organizations for Improved Reliability and Performance: A Not Entirely Unbiased Tutorial (1st revision)

    Full text link
    RAID proposal advocated replacing large disks with arrays of PC disks, but as the capacity of small disks increased 100-fold in 1990s the production of large disks was discontinued. Storage dependability is increased via replication or erasure coding. Cloud storage providers store multiple copies of data obviating for need for further redundancy. Varitaions of RAID based on local recovery codes, partial MDS reduce recovery cost. NAND flash Solid State Disks - SSDs have low latency and high bandwidth, are more reliable, consume less power and have a lower TCO than Hard Disk Drives, which are more viable for hyperscalers.Comment: Submitted to ACM Computing Surveys. arXiv admin note: substantial text overlap with arXiv:2306.0876

    Data allocation in disk arrays with multiple raid levels

    Get PDF
    There has been an explosion in the amount of generated data, which has to be stored reliably because it is not easily reproducible. Some datasets require frequent read and write access. like online transaction processing applications. Others just need to be stored safely and read once in a while, as in data mining. This different access requirements can be solved by using the RAID (redundant array of inexpensive disks) paradigm. i.e., RAIDi for the first situation and RAID5 for the second situation. Furthermore rather than providing two disk arrays with RAID 1 and RAID5 capabilities, a controller can be postulated to emulate both. It is referred as a heterogeneous disk array (HDA). Dedicating a subset of disks to RAID 1 results in poor disk utilization, since RAIDi vs RAID5 capacity and bandwidth requirements are not known a priori. Balancing disk loads when disk space is shared among allocation requests, referred to as virtual arrays - VAs poses a difficult problem. RAIDi disk arrays have a higher access rate per gigabyte than RAID5 disk arrays. Allocating more VAs while keeping disk utilizations balanced and within acceptable bounds is the goal of this study. Given its size and access rate a VA\u27s width or the number of its Virtual Disks -VDs is determined. VDs allocations on physical disks using vector-packing heuristics, with disk capacity and bandwidth as the two dimensions are shown to be the best. An allocation is acceptable if it does riot exceed the disk capacity and overload disks even in the presence of disk failures. When disk bandwidth rather than capacity is the bottleneck, the clustered RAID paradigm is applied, which offers a tradeoff between disk space and bandwidth. Another scenario is also considered where the RAID level is determined by a classification algorithm utilizing the access characteristics of the VA, i.e., fractions of small versus large access and the fraction of write versus read accesses. The effect of RAID 1 organization on its reliability and performance is studied too. The effect of disk failures on the X-code two disk failure tolerant array is analyzed and it is shown that the load across disks is highly unbalanced unless in an NxN array groups of N stripes are randomly rotated
    corecore