21 research outputs found

    Illumination Correction on Biomedical Images

    Get PDF
    RF-Inhomogeneity Correction (aka bias) artifact is an important research field in Magnetic Resonance Imaging (MRI). Bias corrupts MR images altering their illumination even though they are acquired with the most recent scanners. Homomorphic Unsharp Masking (HUM) is a filtering technique aimed at correcting illumination inhomogeneity, but it produces a halo around the edges as a side effect. In this paper a novel correction scheme based on HUM is proposed to correct the artifact mentioned above without introducing the halo. A wide experimentation has been performed on MR images. The method has been tuned and evaluated using the simulated Brainweb image database. In this framework, the approach has been compared successfully against the Guillemaud filter and the SPM2 method. Moreover, the method has been successfully applied on several real MR images of the brain (0.18 T, 1.5 T and 7 T). The description of the overall technique is reported along with the experimental results that show its effectiveness in different anatomical regions and its ability to compensate both underexposed and overexposed areas. Our approach is also effective on non-radiological images, like retinal ones

    Deep learning based correction of RF field induced inhomogeneities for T2w prostate imaging at 7 T

    Get PDF
    At ultrahigh field strengths images of the body are hampered by B1-field inhomogeneities. These present themselves as inhomogeneous signal intensity and contrast, which is regarded as a “bias field” to the ideal image. Current bias field correction methods, such as the N4 algorithm, assume a low frequency bias field, which is not sufficiently valid for T2w images at 7 T. In this work we propose a deep learning based bias field correction method to address this issue for T2w prostate images at 7 T. By combining simulated B1-field distributions of a multi-transmit setup at 7 T with T2w prostate images at 1.5 T, we generated artificial 7 T images for which the homogeneous counterpart was available. Using these paired data, we trained a neural network to correct the bias field. We predicted either a homogeneous image (t-Image neural network) or the bias field (t-Biasf neural network). In addition, we experimented with the single-channel images of the receive array and the corresponding sum of magnitudes of this array as the input image. Testing was carried out on four datasets: the test split of the synthetic training dataset, volunteer and patient images at 7 T, and patient images at 3 T. For the test split, the performance was evaluated using the structural similarity index measure, Wasserstein distance, and root mean squared error. For all other test data, the features Homogeneity and Energy derived from the gray level co-occurrence matrix (GLCM) were used to quantify the improvement. For each test dataset, the proposed method was compared with the current gold standard: the N4 algorithm. Additionally, a questionnaire was filled out by two clinical experts to assess the homogeneity and contrast preservation of the 7 T datasets. All four proposed neural networks were able to substantially reduce the B1-field induced inhomogeneities in T2w 7 T prostate images. By visual inspection, the images clearly look more homogeneous, which is confirmed by the increase in Homogeneity and Energy in the GLCM, and the questionnaire scores from two clinical experts. Occasionally, changes in contrast within the prostate were observed, although much less for the t-Biasf network than for the t-Image network. Further, results on the 3 T dataset demonstrate that the proposed learning based approach is on par with the N4 algorithm. The results demonstrate that the trained networks were capable of reducing the B1-field induced inhomogeneities for prostate imaging at 7 T. The quantitative evaluation showed that all proposed learning based correction techniques outperformed the N4 algorithm. Of the investigated methods, the single-channel t-Biasf neural network proves most reliable for bias field correction.</p

    Deep learning based correction of RF field induced inhomogeneities for T2w prostate imaging at 7 T

    Get PDF
    At ultrahigh field strengths images of the body are hampered by B1-field inhomogeneities. These present themselves as inhomogeneous signal intensity and contrast, which is regarded as a “bias field” to the ideal image. Current bias field correction methods, such as the N4 algorithm, assume a low frequency bias field, which is not sufficiently valid for T2w images at 7 T. In this work we propose a deep learning based bias field correction method to address this issue for T2w prostate images at 7 T. By combining simulated B1-field distributions of a multi-transmit setup at 7 T with T2w prostate images at 1.5 T, we generated artificial 7 T images for which the homogeneous counterpart was available. Using these paired data, we trained a neural network to correct the bias field. We predicted either a homogeneous image (t-Image neural network) or the bias field (t-Biasf neural network). In addition, we experimented with the single-channel images of the receive array and the corresponding sum of magnitudes of this array as the input image. Testing was carried out on four datasets: the test split of the synthetic training dataset, volunteer and patient images at 7 T, and patient images at 3 T. For the test split, the performance was evaluated using the structural similarity index measure, Wasserstein distance, and root mean squared error. For all other test data, the features Homogeneity and Energy derived from the gray level co-occurrence matrix (GLCM) were used to quantify the improvement. For each test dataset, the proposed method was compared with the current gold standard: the N4 algorithm. Additionally, a questionnaire was filled out by two clinical experts to assess the homogeneity and contrast preservation of the 7 T datasets. All four proposed neural networks were able to substantially reduce the B1-field induced inhomogeneities in T2w 7 T prostate images. By visual inspection, the images clearly look more homogeneous, which is confirmed by the increase in Homogeneity and Energy in the GLCM, and the questionnaire scores from two clinical experts. Occasionally, changes in contrast within the prostate were observed, although much less for the t-Biasf network than for the t-Image network. Further, results on the 3 T dataset demonstrate that the proposed learning based approach is on par with the N4 algorithm. The results demonstrate that the trained networks were capable of reducing the B1-field induced inhomogeneities for prostate imaging at 7 T. The quantitative evaluation showed that all proposed learning based correction techniques outperformed the N4 algorithm. Of the investigated methods, the single-channel t-Biasf neural network proves most reliable for bias field correction.</p

    Deep learning based correction of RF field induced inhomogeneities for T2w prostate imaging at 7 T

    Get PDF
    At ultrahigh field strengths images of the body are hampered by B 1 -field inhomogeneities. These present themselves as inhomogeneous signal intensity and contrast, which is regarded as a "bias field" to the ideal image. Current bias field correction methods, such as the N4 algorithm, assume a low frequency bias field, which is not sufficiently valid for T2w images at 7 T. In this work we propose a deep learning based bias field correction method to address this issue for T2w prostate images at 7 T. By combining simulated B 1 -field distributions of a multi-transmit setup at 7 T with T2w prostate images at 1.5 T, we generated artificial 7 T images for which the homogeneous counterpart was available. Using these paired data, we trained a neural network to correct the bias field. We predicted either a homogeneous image (t-Image neural network) or the bias field (t-Biasf neural network). In addition, we experimented with the single-channel images of the receive array and the corresponding sum of magnitudes of this array as the input image. Testing was carried out on four datasets: the test split of the synthetic training dataset, volunteer and patient images at 7 T, and patient images at 3 T. For the test split, the performance was evaluated using the structural similarity index measure, Wasserstein distance, and root mean squared error. For all other test data, the features Homogeneity and Energy derived from the gray level co-occurrence matrix (GLCM) were used to quantify the improvement. For each test dataset, the proposed method was compared with the current gold standard: the N4 algorithm. Additionally, a questionnaire was filled out by two clinical experts to assess the homogeneity and contrast preservation of the 7 T datasets. All four proposed neural networks were able to substantially reduce the B 1 -field induced inhomogeneities in T2w 7 T prostate images. By visual inspection, the images clearly look more homogeneous, which is confirmed by the increase in Homogeneity and Energy in the GLCM, and the questionnaire scores from two clinical experts. Occasionally, changes in contrast within the prostate were observed, although much less for the t-Biasf network than for the t-Image network. Further, results on the 3 T dataset demonstrate that the proposed learning based approach is on par with the N4 algorithm. The results demonstrate that the trained networks were capable of reducing the B 1 -field induced inhomogeneities for prostate imaging at 7 T. The quantitative evaluation showed that all proposed learning based correction techniques outperformed the N4 algorithm. Of the investigated methods, the single-channel t-Biasf neural network proves most reliable for bias field correction

    Advances in Groupwise Image Registration

    Get PDF

    Advances in Groupwise Image Registration

    Get PDF

    Computer aided analysis of inflammatory muscle disease using magnetic resonance imaging

    Get PDF
    Inflammatory muscle disease (myositis) is characterised by inflammation and a gradual increase in muscle weakness. Diagnosis typically requires a range of clinical tests, including magnetic resonance imaging of the thigh muscles to assess the disease severity. In the past, this has been measured by manually counting the number of muscles affected. In this work, a computer-aided analysis of inflammatory muscle disease is presented to help doctors diagnose and monitor the disease. Methods to quantify the level of oedema and fat infiltration from magnetic resonance scans are proposed and the disease quantities determined are shown to have positive correlation against expert medical opinion. The methods have been designed and tested on a database of clinically acquired T1 and STIR sequences, and are proven to be robust despite suboptimal image quality. General background information is first introduced, giving an overview of the medical, technical, and theoretical topics necessary to understand the problem domain. Next, a detailed introduction to the physics of magnetic resonance imaging is given. A review of important literature from similar and related domains is presented, with valuable insights that are utilised at a later stage. Scans are carefully pre-processed to bring all slices in to a common frame of reference and the methods to quantify the level of oedema and fat infiltration are defined and shown to have good positive correlation with expert medical opinion. A number of validation tests are performed with re-scanned subjects to indicate the level of repeatability. The disease quantities, together with statistical features from the T1-STIR joint histogram, are used for automatic classification of the disease severity. Automatic classification is shown to be successful on out of sample data for both the oedema and fat infiltration problems

    Advancements and Breakthroughs in Ultrasound Imaging

    Get PDF
    Ultrasonic imaging is a powerful diagnostic tool available to medical practitioners, engineers and researchers today. Due to the relative safety, and the non-invasive nature, ultrasonic imaging has become one of the most rapidly advancing technologies. These rapid advances are directly related to the parallel advancements in electronics, computing, and transducer technology together with sophisticated signal processing techniques. This book focuses on state of the art developments in ultrasonic imaging applications and underlying technologies presented by leading practitioners and researchers from many parts of the world

    Computer integrated system: medical imaging & visualization

    Get PDF
    The intent of this book’s conception is to present research work using a user centered design approach. Due to space constraints, the story of the journey, included in this book is relatively brief. However we believe that it manages to adequately represent the story of the journey, from its humble beginnings in 2008 to the point where it visualizes future trends amongst both researchers and practitioners across the Computer Science and Medical disciplines. This book aims not only to present a representative sampling of real-world collaboration between said disciplines but also to provide insights into the different aspects related to the use of real-world Computer Assisted Medical applications. Readers and potential clients should find the information particularly useful in analyzing the benefits of collaboration between these two fields, the products in and of their institutions. The work discussed here is a compilation of the work of several PhD students under my supervision, who have since graduated and produced several publications either in journals or proceedings of conferences. As their work has been published, this book will be more focused on the research methodology based on medical technology used in their research. The research work presented in this book partially encompasses the work under the MOA for collaborative Research and Development in the field of Computer Assisted Surgery and Diagnostics pertaining to Thoracic and Cardiovascular Diseases between UPM, UKM and IJN, spanning five years beginning from 15 Feb 2013

    The Impact of Digital Technologies on Public Health in Developed and Developing Countries

    Get PDF
    This open access book constitutes the refereed proceedings of the 18th International Conference on String Processing and Information Retrieval, ICOST 2020, held in Hammamet, Tunisia, in June 2020.* The 17 full papers and 23 short papers presented in this volume were carefully reviewed and selected from 49 submissions. They cover topics such as: IoT and AI solutions for e-health; biomedical and health informatics; behavior and activity monitoring; behavior and activity monitoring; and wellbeing technology. *This conference was held virtually due to the COVID-19 pandemic
    corecore