2,862 research outputs found
Recommended from our members
An evaluation of energy expenditure estimation by three activity monitors
This is an Author's Accepted Manuscript of an article published in European Journal of Sport Science, 13(6), 681 - 688, 2013 [date of publication] [copyright Taylor & Francis], available online at: http://www.tandfonline.com/ 10.1080/17461391.2013.776639.A comparative evaluation of the ability of activity monitors to predict energy expenditure (EE) is necessary to aid in the investigation of the effect of EE on health. The purpose of this study was to validate and compare the RT3, the SWA and the IDEEA at measuring EE in adults and children. Twenty-six adults and 22 children completed a resting metabolic rate (RMR) test and performed four treadmill activities at 3 km.h−1, 6 km.h−1, 6 km.h−1 at a 10% incline, 9 km.h−1. EE was assessed throughout the protocol by the RT3, the SWA and the IDEEA. Indirect calorimetry (IC) was used as a criterion measure of EE against which each monitor was compared. Mean bias was assessed by subtracting EE from IC from EE from each monitor for each activity. Limit of agreement plots were used to assess the agreement between each monitor and IC. Limits of agreement for resting EE were narrowest for the RT3 for adults and children. Although the IDEEA displayed the smallest mean bias between measures at 3 km.h−1, 6 km.h−1 and 9 km.h−1 in adults and children, the SWA agreed closest with IC at 6 km.h−1, 6 km.h−1 at a 10% incline and 9 km.h−1. Limits of agreement were closest for the SWA at 9 km.h−1 in adults representing 42% of the overall mean EE. Although the RT3 provided the best estimate of resting EE in adults and children, the SWA provided the most accurate estimate of EE across a range of physical activity intensities
A Comparison of Video and Accelerometer Based Approaches Applied to Performance Monitoring in Swimming.
The aim of this paper is to present a comparison of video- and sensor based studies of swimming performance. The video-based approach is reviewed and contrasted to the newer sensor-based technology, specifically accelerometers based upon Micro-Electro-Mechanical Systems (MEMS) technology. Results from previously published swim performance studies using both the video and sensor technologies are summarised and evaluated against the conventional theory that upper arm
movements are of primary interest when quantifying free-style technique. The authors conclude that multiple sensor-based measurements of swimmers’ acceleration profiles have the potential to offer significant advances in coaching technique over the traditional video based approach
Detection of pediatric upper extremity motor activity and deficits with accelerometry
Importance: Affordable, quantitative methods to screen children for developmental delays are needed. Motor milestones can be an indicator of developmental delay and may be used to track developmental progress. Accelerometry offers a way to gather real-world information about pediatric motor behavior.
Objective: To develop a referent cohort of pediatric accelerometry from bilateral upper extremities (UEs) and determine whether movement can accurately distinguish those with and without motor deficits.
Design, Setting, and Participants: Children aged 0 to 17 years participated in a prospective cohort from December 8, 2014, to December 29, 2017. Children were recruited from Ranken Jordan Pediatric Bridge Hospital, Maryland Heights, Missouri, and Washington University School of Medicine in St Louis, St Louis, Missouri. Typically developing children were included as a referent cohort if they had no history of motor or neurological deficit; consecutive sampling and matching ensured equal representation of sex and age. Children with diagnosed asymmetric motor deficits were included in the motor impaired cohort.
Exposures: Bilateral UE motor activity was measured using wrist-worn accelerometers for a total of 100 hours in 25-hour increments.
Main Outcomes and Measures: To characterize bilateral UE motor activity in a referent cohort for the purpose of detecting irregularities in the future, total activity and the use ratio between UEs were used to describe typically developing children. Asymmetric impairment was classified using the mono-arm use index (MAUI) and bilateral-arm use index (BAUI) to quantify the acceleration of unilateral movements.
Results: A total of 216 children enrolled, and 185 children were included in analysis. Of these, 156 were typically developing, with mean (SD) age 9.1 (5.1) years and 81 boys (52.0%). There were 29 children in the motor impaired cohort, with mean (SD) age 7.4 (4.4) years and 16 boys (55.2%). The combined MAUI and BAUI (mean [SD], 0.86 [0.005] and use ratio (mean [SD], 0.90 [0.008]) had similar F1 values. The area under the curve was also similar between the combined MAUI and BAUI (mean [SD], 0.98 [0.004]) and the use ratio (mean [SD], 0.98 [0.004]).
Conclusions and Relevance: Bilateral UE movement as measured with accelerometry may provide a meaningful metric of real-world motor behavior across childhood. Screening in early childhood remains a challenge; MAUI may provide an effective method for clinicians to measure and visualize real-world motor behavior in children at risk for asymmetrical deficits
Recommended from our members
Validation of a consumer-grade activity monitor for continuous daily activity monitoring in individuals with multiple sclerosis.
Background:Technological advancements of remote-monitoring used in clinical-care and research require validation of model updates. Objectives:To compare the output of a newer consumer-grade accelerometer to a previous model in people with multiple sclerosis (MS) and to the ActiGraph, a waist-worn device widely used in MS research. Methods:Thirty-one individuals with MS participated in a 7-day validation by the Fitbit Flex (Flex), Fitbit Flex-2 (Flex2) and ActiGraph GT3X. Primary outcome was step count. Valid epochs of 5-min block increments, where there was overlap of ≥1 step/min for both devices were compared and summed to give a daily total for analysis. Results:Bland-Altman plots showed no systematic difference between the Flex and Flex2; mean step-count difference of 25 more steps-per-day more recorded by Flex2 (95% confidence intervals (CI) = 2, 48; p = 0.04),interclass correlation coefficient (ICC) = 1.00. Compared to the ActiGraph, Flex2 (and Flex) tended to record more steps (808 steps-per-day more than the ActiGraph (95% CI= -2380, 765; p < 0.01), although the ICC was high (0.98) indicating that the devices were likely measuring the same kind of activity. Conclusions:Steps from Flex and Flex2 can be used interchangeably. Differences in total step count between ActiGraph and Flex devices can make cross-device comparisons of numerical step-counts challenging particularly for faster walkers
Gender and school-level differences in students' moderate and vigorous physical activity levels when taught basketball through the tactical games model
The Tactical Games Model (TGM) prefaces the cognitive components of physical education (PE), which has implications for physical activity (PA) accumulation. PA recommendations suggest students reach 50% moderate-vigorous physical activity (MVPA). However, this criterion does not indicate the contribution from vigorous physical activity (VPA). Consequently, this study investigated: a) the effects of TGM delivery on MVPA/VPA and, b) gender/school level differences. Participants were 78 seventh and 96 fourth/fifth grade coeducational PE students from two different schools. Two teachers taught 24 (middle) and 30 (elementary) level one TGM basketball lessons. Students wore Actigraph GT3× triaxial accelerometers. Data were analyzed using four one-way ANOVAs. Middle school boys had significantly higher MVPA/VPA (34.04/22.37%) than girls (25.14/15.47%). Elementary school boys had significantly higher MVPA/VPA (29.73/18.33%) than girls (23.03/14.33%). While TGM lessons provide a context where students can accumulate VPA consistent with national PA recommendations, teachers need to modify lesson activities to enable equitable PA participation
Aerobic capacity, activity levels and daily energy expenditure in male and female adolescents of the kenyan nandi sub-group
The relative importance of genetic and socio-cultural influences contributing to the success of east Africans in endurance athletics remains unknown in part because the pre-training phenotype of this population remains incompletely assessed. Here cardiopulmonary fitness, physical activity levels, distance travelled to school and daily energy expenditure in 15 habitually active male (13.9±1.6 years) and 15 habitually active female (13.9±1.2) adolescents from a rural Nandi primary school are assessed. Aerobic capacity ([Formula: see text]) was evaluated during two maximal discontinuous incremental exercise tests; physical activity using accelerometry combined with a global positioning system; and energy expenditure using the doubly labelled water method. The [Formula: see text] of the male and female adolescents were 73.9±5.7 ml(.) kg(-1.) min(-1) and 61.5±6.3 ml(.) kg(-1.) min(-1), respectively. Total time spent in sedentary, light, moderate and vigorous physical activities per day was 406±63 min (50% of total monitored time), 244±56 min (30%), 75±18 min (9%) and 82±30 min (10%). Average total daily distance travelled to and from school was 7.5±3.0 km (0.8-13.4 km). Mean daily energy expenditure, activity-induced energy expenditure and physical activity level was 12.2±3.4 MJ(.) day(-1), 5.4±3.0 MJ(.) day(-1) and 2.2±0.6. 70.6% of the variation in [Formula: see text] was explained by sex (partial R(2) = 54.7%) and body mass index (partial R(2) = 15.9%). Energy expenditure and physical activity variables did not predict variation in [Formula: see text] once sex had been accounted for. The highly active and energy-demanding lifestyle of rural Kenyan adolescents may account for their exceptional aerobic fitness and collectively prime them for later training and athletic success
Real-time human ambulation, activity, and physiological monitoring:taxonomy of issues, techniques, applications, challenges and limitations
Automated methods of real-time, unobtrusive, human ambulation, activity, and wellness monitoring and data analysis using various algorithmic techniques have been subjects of intense research. The general aim is to devise effective means of addressing the demands of assisted living, rehabilitation, and clinical observation and assessment through sensor-based monitoring. The research studies have resulted in a large amount of literature. This paper presents a holistic articulation of the research studies and offers comprehensive insights along four main axes: distribution of existing studies; monitoring device framework and sensor types; data collection, processing and analysis; and applications, limitations and challenges. The aim is to present a systematic and most complete study of literature in the area in order to identify research gaps and prioritize future research directions
Recommended from our members
Comparison of hip and wrist accelerometers in a pre-adolescent population in free-living and semi-structured physical activity
PURPOSE: The primary aim of this study was to examine the accuracy of a hip (Evenson algorithm) and wrist-worn (Crouter algorithm) accelerometer in assessing time spent in different intensity categories in pre-adolescent girls during semi-structured dance classes using direct observation (D.O.) as the criterion measure. The secondary aim of this study was to examine the validity of a wrist-worn accelerometer for dichotomizing pre-adolescent girls as meeting or not meeting different preselected doses of moderate-to-vigorous PA compared to the hip-worn accelerometer. METHODS: Data were collected and analyzed on a total of 6 participants (age = 10.22 ± 2.38) for the primary aim. Additionally, data was collected and analyzed on a total of 20 participants (age = 8.6 ± 1.6) for the secondary aim. RESULTS: Compared to D.O., the wrist-worn accelerometer was inaccurate in measuring time spent in light PA, vigorous PA and MVPA. Additionally, the hip-worn accelerometer was inaccurate in measuring time spent in sedentary time, light PA, vigorous PA and total PA. Further, for the secondary aim, there was a significant difference between device location and meeting PA dosage for three days and five days. CONCLUSION: Traditional accelerometer algorithms rely on the activity count cut-point method which provides mixed to poor results of activity intensity classification regardless of wear location. Future research should move away from the activity count cut-point method and aim to develop algorithms that use more of the rich data available from the accelerometers’ acceleration signal
- …