29,653 research outputs found

    An Adaptive Overcurrent Coordination Scheme to Improve Relay Sensitivity and Overcome Drawbacks due to Distributed Generation in Smart Grids

    Get PDF
    Distributed Generation (DG) brought new challenges for protection engineers since standard relay settings of traditional system may no longer function properly under increasing presence of DG. The extreme case is coordination loss between primary and backup relays. The directional overcurrent relay (DOCR) which is the most implemented protective device in the electrical network also suffers performance degradation in presence of DG. Therefore, this paper proposes the mitigation of DG impact on DOCR coordination employing adaptive protection scheme (APS) using differential evolution algorithm (DE) while improving overall sensitivity of relays . The impacts of DG prior and after the application of APS are presented based on interconnected 6 bus and IEEE 14 bus system. As a consequence, general sensitivity improvement and mitigation scheme is proposed

    Fault detection and location in DC systems from initial di/dt measurement

    Get PDF
    The use of DC for primary power distribution has the potential to bring significant design, cost and efficiency benefits to a range of power transmission and distribution applications. The use of active converter technologies within these networks is a key enabler for these benefits to be realised, however their integration can lead to exceptionally demanding electrical fault protection requirements, both in terms of speed and fault discrimination. This paper describes a novel fault detection method which exceeds the capability of many current protection methods in order to meet these requirements. The method utilises fundamental characteristics of the converter filter capacitance’s response to electrical system faults to estimate fault location through a measurement of fault path inductance. Crucially, the method has the capability to detect and discriminate fault location within microseconds of the fault occurring, facilitating its rapid removal from the network

    Exploiting multi-agent system technology within an autonomous regional active network management system

    Get PDF
    This paper describes the proposed application of multi-agent system (MAS) technology within AuRA-NMS, an autonomous regional network management system currently being developed in the UK through a partnership between several UK universities, distribution network operators (DNO) and a major equipment manufacturer. The paper begins by describing the challenges facing utilities and why those challenges have led the utilities, a major manufacturer and the UK government to invest in the development of a flexible and extensible active network management system. The requirements the utilities have for a network automation system they wish to deploy on their distribution networks are discussed in detail. With those requirements in mind the rationale behind the use of multi-agent systems (MAS) within AuRA-NMS is presented and the inherent research and design challenges highlighted including: the issues associated with robustness of distributed MAS platforms; the arbitration of different control functions; and the relationship between the ontological requirements of Foundation for Intelligent Physical Agent (FIPA) compliant multi-agent systems, legacy protocols and standards such as IEC 61850 and the common information model (CIM)

    Demonstration of adaptive overcurrent protection using IEC 61850 communications

    Get PDF
    This paper contains a description of an adaptive protection scheme that has been implemented and demonstrated in a hardware in the loop simulation environment using commercially available protection hardware and IEC 61850 communications.The implementation is based on an actual 11kV system which includes distributed generation and network automation. IEC 61850 communications offers several benefits for the implementation of adaptive protection, but also presents some limitations which are discussed in the paper. An alternative approach to overcome a number of the limitations is also presented

    Line protection in inverter supplied networks

    Get PDF
    New protection methods are required to protect a distribution system when supplied by current limited converters. In this paper, a method of converter control is proposed to limit the current by reducing the voltage in the faulted phase or phases while keeping the voltage of the healthy phases unaltered. Unsymmetrical fault analysis is performed to calculate the sequence currents and voltages at the relay location, when system is supplied by a converter. Based on that converter control, distance relay performances have been evaluated in both grid-connected and islanded mode operations. Distance relay, combined with MHO and negative sequence impedance directional characteristics, is proposed as a protection scheme for the distribution system for different types of faults under the current limited environment. The results are validated through PSCAD/EMTDC simulation and MATLAB calculations

    An Intelligent Fuse-box for use with Renewable Energy Sources integrated within a Domestic Environment

    No full text
    This paper outlines a proposal for an intelligent fuse-box that can replace existing fuse-boxes in a domestic context such that a number of renewable energy sources can easily be integrated into the domestic power supply network, without the necessity for complex islanding and network protection. The approach allows intelligent control of both the generation of power and its supply to single or groups of electrical appliances. Energy storage can be implemented in such a scheme to even out the power supplied and simplify the control scheme required, and environmental monitoring and load analysis can help in automatically controlling the supply and demand profiles for optimum electrical and economic efficiency. Simulations of typical scenarios are carried out to illustrate the concept in operation

    International White Book on DER Protection : Review and Testing Procedures

    Get PDF
    This white book provides an insight into the issues surrounding the impact of increasing levels of DER on the generator and network protection and the resulting necessary improvements in protection testing practices. Particular focus is placed on ever increasing inverter-interfaced DER installations and the challenges of utility network integration. This white book should also serve as a starting point for specifying DER protection testing requirements and procedures. A comprehensive review of international DER protection practices, standards and recommendations is presented. This is accompanied by the identifi cation of the main performance challenges related to these protection schemes under varied network operational conditions and the nature of DER generator and interface technologies. Emphasis is placed on the importance of dynamic testing that can only be delivered through laboratory-based platforms such as real-time simulators, integrated substation automation infrastructure and fl exible, inverter-equipped testing microgrids. To this end, the combination of fl exible network operation and new DER technologies underlines the importance of utilising the laboratory testing facilities available within the DERlab Network of Excellence. This not only informs the shaping of new protection testing and network integration practices by end users but also enables the process of de-risking new DER protection technologies. In order to support the issues discussed in the white paper, a comparative case study between UK and German DER protection and scheme testing practices is presented. This also highlights the level of complexity associated with standardisation and approval mechanisms adopted by different countries
    corecore