    NONINVASIVE MULTIMODAL DIFFUSE OPTICAL IMAGING OF VULNERABLE TISSUE HEMODYNAMICS

    Get PDF
    Measurement of tissue hemodynamics provides vital information for the assessment of tissue viability. This thesis reports three noninvasive near-infrared diffuse optical systems for spectroscopic measurements and tomographic imaging of tissue hemodynamics in vulnerable tissues with the goal of disease diagnosis and treatment monitoring. A hybrid near-infrared spectroscopy/diffuse correlation spectroscopy (NIRS/DCS) instrument with a contact fiber-optic probe was developed and utilized for simultaneous and continuous monitoring of blood flow (BF), blood oxygenation, and oxidative metabolism in exercising gastrocnemius. Results measured by the hybrid NIRS/DCS instrument in 37 subjects (mean age: 67 ± 6) indicated that vitamin D supplement plus aerobic training improved muscle metabolic function in older population. To reduce the interference and potential infection risk on vulnerable tissues caused by the contact measurement, a noncontact diffuse correlation spectroscopy/tomography (ncDCS/ncDCT) system was then developed. The ncDCS/ncDCT system employed optical lenses to project limited numbers of sources and detectors on the tissue surface. A motor-driven noncontact probe scanned over a region of interest to collect boundary data for three dimensional (3D) tomographic imaging of blood flow distribution. The ncDCS was tested for BF measurements in mastectomy skin flaps. Nineteen (19) patients underwent mastectomy and implant-based breast reconstruction were measured before and immediately after mastectomy. The BF index after mastectomy in each patient was normalized to its baseline value before surgery to get relative BF (rBF). Since rBF values in the patients with necrosis (n = 4) were significantly lower than those without necrosis (n = 15), rBF levels can be used to predict mastectomy skin flap necrosis. The ncDCT was tested for 3D imaging of BF distributions in chronic wounds of 5 patients. Spatial variations in BF contrasts over the wounded tissues were observed, indicating the capability of ncDCT in detecting tissue hemodynamic heterogeneities. To improve temporal/spatial resolution and avoid motion artifacts due to a long mechanical scanning of ncDCT, an electron-multiplying charge-coupled device based noncontact speckle contrast diffuse correlation tomography (scDCT) was developed. Validation of scDCT was done by imaging both high and low BF contrasts in tissue-like phantoms and human forearms. In a wound imaging study using scDCT, significant lower BF values were observed in the burned areas/volumes compared to surrounding normal tissues in two patients with burn. One limitation in this study was the potential influence of other unknown tissue optical properties such as tissue absorption coefficient (”a) on BF measurements. A new algorithm was then developed to extract both ”a and BF using light intensities and speckle contrasts measured by scDCT at multiple source-detector distances. The new algorithm was validated using tissue-like liquid phantoms with varied values of ”a and BF index. In-vivo validation and application of the innovative scDCT technique with the new algorithm is the subject of future work

    Cardiovascular assessment by imaging photoplethysmography – a review

    Get PDF
    AbstractOver the last few years, the contactless acquisition of cardiovascular parameters using cameras has gained immense attention. The technique provides an optical means to acquire cardiovascular information in a very convenient way. This review provides an overview on the technique’s background and current realizations. Besides giving detailed information on the most widespread application of the technique, namely the contactless acquisition of heart rate, we outline further concepts and we critically discuss the current state.</jats:p

    Noninvasive Blood Flow and Oxygenation Measurements in Diseased Tissue

    Get PDF
    The research presented in this dissertation focused on the application of optical imaging techniques to establish blood flow and oxygen saturation as effective biomarkers for two disease cases, Autism Spectrum Disorder (ASD) and Huntington’s Disease (HD). The BTBR mouse model of ASD was utilized to validate measurements of cerebral blood flow and oxygenation as biomarkers for autism. The R6/2 mouse model of juvenile HD was utilized to validate measurements of skeletal muscle blood flow following tetanic muscle contractions induced by electrical nerve stimulation. Next, a noncontact, camera-based system to measure blood flow and oxygen saturation maps was implemented to improve upon the previous HD mouse results by providing spatial heterogeneity in a wild-type mouse model. Finally, translational research was performed to validate a research design conducting concurrent grip strength force and skeletal muscle blood flow and oxygenation measurements in a healthy human population that will be used to establish HD biomarkers in humans in future clinical applications

    Opto-physiological modeling applied to photoplethysmographic cardiovascular assessment

    Get PDF
    This paper presents opto-physiological (OP) modeling and its application in cardiovascular assessment techniques based on photoplethysmography (PPG). Existing contact point measurement techniques, i.e., pulse oximetry probes, are compared with the next generation noncontact and imaging implementations, i.e., non-contact reflection and camera-based PPG. The further development of effective physiological monitoring techniques relies on novel approaches to OP modeling that can better inform the design and development of sensing hardware and applicable signal processing procedures. With the help of finite-element optical simulation, fundamental research into OP modeling of photoplethysmography is being exploited towards the development of engineering solutions for practical biomedical systems. This paper reviews a body of research comprising two OP models that have led to significant progress in the design of transmission mode pulse oximetry probes, and approaches to 3D blood perfusion mapping for the interpretation of cardiovascular performance

    Measuring the Physiologic Properties of Oral Lesions Receiving Fractionated Photodynamic Therapy

    Full text link
    Photodynamic therapy (PDT) can treat superficial, early‐stage disease with minimal damage to underlying tissues and without cumulative dose‐limiting toxicity. Treatment efficacy is affected by disease physiologic properties, but these properties are not routinely measured. We assessed diffuse reflectance spectroscopy (DRS) for the noninvasive, contact measurement of tissue hemoglobin oxygen saturation (StO2) and total hemoglobin concentration ([tHb]) in the premalignant or superficial microinvasive oral lesions of patients treated with 5‐aminolevulinic acid (ALA)‐PDT. Patients were enrolled on a Phase 1 study of ALA‐PDT that evaluated fluences of 50, 100, 150 or 200 J cm−2 delivered at 100 mW cm−2. To test the feasibility of incorporating DRS measurements within the illumination period, studies were performed in patients who received fractionated (two‐part) illumination that included a dark interval of 90–180 s. Using DRS, tissue oxygenation at different depths within the lesion could also be assessed. DRS could be performed concurrently with contact measurements of photosensitizer levels by fluorescence spectroscopy, but a separate noncontact fluorescence spectroscopy system provided continuous assessment of photobleaching during illumination to greater tissue depths. Results establish that the integration of DRS into PDT of early‐stage oral disease is feasible, and motivates further studies to evaluate its predictive and dosimetric value.Diffuse reflectance spectroscopy with a contact probe was employed as part of a fluorescence and reflectance spectroscopy system to measure the tissue hemoglobin oxygen saturation and hemoglobin content of lesions of premalignant or early microinvasive cancer of the oral cavity. Studies demonstrate the feasibility of incorporating these measurements into treatment with fractionated (two‐part) photodynamic therapy (PDT) using 5‐aminolevulinic acid. Patient‐specific differences in physiologic parameters were detectable at baseline and at times during and after PDT. Photobleaching of photosensitizer was measured by its fluorescence. Results establish the utility of rationally designed spectroscopy probes toward personalized dosimetry in PDT of oral disease.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/113767/1/php12475.pd

    Scanning, non-contact, hybrid broadband diffuse optical spectroscopy and diffuse correlation spectroscopy system

    Get PDF
    A scanning system for small animal imaging using non-contact, hybrid broadband diffuse optical spectroscopy (ncDOS) and diffuse correlation spectroscopy (ncDCS) is presented. The ncDOS uses a two-dimensional spectrophotometer retrieving broadband (610-900 nm) spectral information from up to fifty-seven source-detector distances between 2 and 5 mm. The ncDCS data is simultaneously acquired from four source-detector pairs. The sample is scanned in two dimensions while tracking variations in height. The system has been validated with liquid phantoms, demonstrated in vivo on a human fingertip during an arm cuff occlusion and on a group of mice with xenoimplanted renal cell carcinoma. (C) 2016 Optical Society of Americ

    Detection of psychological stress using a hyperspectral imaging technique

    Get PDF
    The detection of stress at early stages is beneficial to both individuals and communities. However, traditional stress detection methods that use physiological signals are contact-based and require sensors to be in contact with test subjects for measurement. In this paper, we present a method to detect psychological stress in a non-contact manner using a human physiological response. In particular, we utilize a hyperspectral imaging (HSI) technique to extract the tissue oxygen saturation (StO2) value as a physiological feature for stress detection. Our experimental results indicate that this new feature may be independent from perspiration and ambient temperature. Trier Social Stress Tests (TSSTs) on 21 volunteers demonstrated a significant difference p\< 0.005 and a large practical discrimination (d 1/4 1.37) between normalized baseline and stress StO2 levels. The accuracy for stress recognition from baseline using a binary classifier was 76.19 and 88.1 percent for the automatic and manual selections of the classifier threshold, respectively. These results suggest that the StO2 level could serve as a new modality to recognize stress at standoff distances

    Imaging photoplethysmography: towards effective physiological measurements

    Get PDF
    Since its conception decades ago, Photoplethysmography (PPG) the non-invasive opto-electronic technique that measures arterial pulsations in-vivo has proven its worth by achieving and maintaining its rank as a compulsory standard of patient monitoring. However successful, conventional contact monitoring mode is not suitable in certain clinical and biomedical situations, e.g., in the case of skin damage, or when unconstrained movement is required. With the advance of computer and photonics technologies, there has been a resurgence of interest in PPG and one potential route to overcome the abovementioned issues has been increasingly explored, i.e., imaging photoplethysmography (iPPG). The emerging field of iPPG offers some nascent opportunities in effective and comprehensive interpretation of the physiological phenomena, indicating a promising alternative to conventional PPG. Heart and respiration rate, perfusion mapping, and pulse rate variability have been accessed using iPPG. To effectively and remotely access physiological information through this emerging technique, a number of key issues are still to be addressed. The engineering issues of iPPG, particularly the influence of motion artefacts on signal quality, are addressed in this thesis, where an engineering model based on the revised Beer-Lambert law was developed and used to describe opto-physiological phenomena relevant to iPPG. An iPPG setup consisting of both hardware and software elements was developed to investigate its reliability and reproducibility in the context of effective remote physiological assessment. Specifically, a first study was conducted for the acquisition of vital physiological signs under various exercise conditions, i.e. resting, light and heavy cardiovascular exercise, in ten healthy subjects. The physiological parameters derived from the images captured by the iPPG system exhibited functional characteristics comparable to conventional contact PPG, i.e., maximum heart rate difference was <3 bpm and a significant (p < 0.05) correlation between both measurements were also revealed. Using a method for attenuation of motion artefacts, the heart rate and respiration rate information was successfully assessed from different anatomical locations even in high-intensity physical exercise situations. This study thereby leads to a new avenue for noncontact sensing of vital signs and remote physiological assessment, showing clear and promising applications in clinical triage and sports training. A second study was conducted to remotely assess pulse rate variability (PRV), which has been considered a valuable indicator of autonomic nervous system (ANS) status. The PRV information was obtained using the iPPG setup to appraise the ANS in ten normal subjects. The performance of the iPPG system in accessing PRV was evaluated via comparison with the readings from a contact PPG sensor. Strong correlation and good agreement between these two techniques verify the effectiveness of iPPG in the remote monitoring of PRV, thereby promoting iPPG as a potential alternative to the interpretation of physiological dynamics related to the ANS. The outcomes revealed in the thesis could present the trend of a robust non-contact technique for cardiovascular monitoring and evaluation

    Camera-Based Remote Photoplethysmography for Estimation of Heart Rate using Single Board Computers

    Get PDF
    The objective of this project was to develop a wireless, noncontact monitoring system that measures multiple physiological parameters in human faces from a distance using a camera. Compared to traditional sensors, this monitoring system does not use wires or adhesives, providing a safer, more user-friendly application. The goal of the monitoring systems was to estimate heart rate (HR). The current practices of measuring HR involve collecting electrocardiogram (ECG) signals from adhesive electrodes placed on various parts of the body and using a pulse oximeter (PO) typically placed on the ear lobe or finger. We were able to successfully create 2 monitoring systems and compare their results to the PO. Both monitoring systems are low-cost at less than $200. Neither system has been shown to exist in literature thus making them novel implementations. After analysis, we found the estimated HR from one of the systems to be not significantly different from the PO readings. In conclusion, we were able to estimate HR from a distance using a camera-based system which can have many useful applications, potentially in the Neonatal ICU and in other home health settings
    • 