    Screen-Printed Chipless Wireless Temperature Sensor

    Get PDF
    A chipless wireless sensor for temperature monitoring is described in this work. The sensor is fabricated by screen printing of an RLC circuit on a flexible substrate. The sensing element is a resistive carbon paste with positive temperature coefficient placed in a small area in the interconnection between the inductor and the capacitor. This sensing layer modifies the resonance frequency of the circuit when the temperature varies. We also show the influence of the sensor sensitivity with respect to the reading distance

    Generalized Parity-Time Symmetry Condition for Enhanced Sensor Telemetry

    Full text link
    Wireless sensors based on micro-machined tunable resonators are important in a variety of applications, ranging from medical diagnosis to industrial and environmental monitoring.The sensitivity of these devices is, however, often limited by their low quality (Q) factor.Here, we introduce the concept of isospectral party time reciprocal scaling (PTX) symmetry and show that it can be used to build a new family of radiofrequency wireless microsensors exhibiting ultrasensitive responses and ultrahigh resolution, which are well beyond the limitations of conventional passive sensors. We show theoretically, and demonstrate experimentally using microelectromechanical based wireless pressure sensors, that PTXsymmetric electronic systems share the same eigenfrequencies as their parity time (PT)-symmetric counterparts, but crucially have different circuit profiles and eigenmodes. This simplifies the electronic circuit design and enables further enhancements to the extrinsic Q factor of the sensors

    A Harsh Environment-Oriented Wireless Passive Temperature Sensor Realized by LTCC Technology

    No full text
    To meet measurement needs in harsh environments, such as high temperature and rotating applications, a wireless passive Low Temperature Co-fired Ceramics (LTCC) temperature sensor based on ferroelectric dielectric material is presented in this paper. As a LC circuit which consists of electrically connected temperature sensitive capacitor and invariable planar spiral inductor, the sensor has its resonant frequency shift with the variation in temperature. Within near-filed coupling distance, the variation in resonant frequency of the sensor can be detected contactlessly by extracting the impedance parameters of an external antenna. Ferroelectric ceramic, which has temperature sensitive permittivity, is used as the dielectric. The fabrication process of the sensor, which differs from conventional LTCC technology, is described in detail. The sensor is tested three times from room temperature to 700 °C, and considerable repeatability and sensitivity are shown, thus the feasibility of high performance wireless passive temperature sensor realized by LTCC technology is demonstrated

    Passive Wireless Temperature Sensing in Extreme Harsh Environments

    Get PDF
    As the technology in the elds of aerospace and the US power generation industry advances, there is a critical need for new extreme high temperature sensing / monitoring technologies to replace the current out-of-date sensing systems. As the operating temperatures of these jet and turbine engines continue to rise over 1000 C, it is vitally important to monitor the extreme high temperatures in these engines for system health monitoring and to achieve greater engine eciencies. We propose a new passive wireless temperature sensor capable of sensing these extreme high temperatures. The sensor uses an LC resonance circuit to measure the temperature through passive wireless communications. A new novel method of capturing large quantities of frequency information from the sensor is proposed and allows for advanced signal processing methods form other applications areas like wireless communi- cations, radar, and radio astronomy to be implemented. The passive wireless LC resonance high temperature sensor was successfully able to sense temperatures up to 700 C

    Sensors for Wireless Body Monitoring Applications

    Get PDF
    Body monitoring systems have recently drawn great attention to modern electronic consumers due to their various health−care and security applications. However, most of the existing monitoring systems need wire connections that prevent free body movements. Complementary metal−oxide−semiconductor (CMOS) technology based wireless sensor systems need integration of different components that make the device volume and production cost high. In adition, their dependency on on−sensor power source limits the continuous monitoring capability. In the thesis, to demonstrate the feasibility of low cost and simple body monitoring systems, we propose a near−infrared (NIR) photodetector (PD) and a humidity sensor (HS) using low−temperature thin−film processes suitable for large−area electronics application. For NIR detection, a novel lateral metal−semiconductor−metal (MSM) PD architecture is proposed using low−temperature nanocrystalline silicon (nc−Si) as a NIR absorption layer and organic polyimide (PI) as a blocking layer. Experimental results show that addition of PI layer reduces the dark current (ID) up to 103−105 times compared with the PDs without PI layer. Fabricated devices exhibit a low ID of ~10−10 A, a response time of <1.5 ms, and an external quantum efficiency (EQE) of 35−15% for the 740−850 nm wavelengths of light under 100−150 V biasing conditions. Unlike the standard p−i−n PD, our high−performance lateral PD does not require doped p+ and n+ layers. Thus, the reported device is compatible with industry standard amorphous silicon (a−Si) thin−film transistor (TFT) fabrication process, which makes it promising for large−area full hand biometric imagers suitable for various non−invasive body monitoring applications. For humidity detection, a 30 mm diameter passive LC (p−LC) HS is formed by joining an octagonal planer inductor and a moisture sensitive interdigital zinc oxide (ZnO) capacitor in series. A PCB reader coil is also designed, which is able to sense the HS from <25 mm distance. The HS reads 30−90% of relative humidity (RH) by interrogating change of the resonance frequency (fR) of the reader−sensor system. The reading resolution is ±2.38%RH and the sensitivity is 53.33−93.33 kHz/1%RH for the above 45% RH measurements. Experimental results show that the proposed HS is operational in a range of 0−75 oC as long as recalibration is performed for a temperature drift of above ±3 oC, which makes it suitable for various promising applications operated at different temperatures. Above all, the presented results are promising for the continuous body monitoring applications to observe the humidity wirelessly without any power source on the sensor

    The design and development of a planar coil sensor for angular displacements

    Get PDF
    The increased prevalence of wearable sensing devices is accelerating the development of personalised medical devices for monitoring the human condition. The measurement of joint posture and kinematics is particularly relevant in areas of physiotherapy and in the management of diseases. Existing sensors for performing these tasks are however, either inaccurate or too technically complex and obtrusive. A novel approach has been taken to develop a new type of sensor for angular displacement sensing. This thesis describes the development of a series of novel inductive planar coil sensors for measuring angular displacement. The small profile of these sensors makes them ideal for integration into garments as part of wearable devices. The main objective of this work was to design a planar coil topology, based on an inductive methodology, suitable for measuring angular displacements typically observed in finger articulation. Finite Element Method software was initially employed to determine the feasibility of various coil topologies. The planar coils were subsequently manufactured on several types of substrate including rigid printed circuit boards and flexible polyester films incorporating an iron-based amorphous ribbon as the inductive element. A series of experimental investigations involving inductance and stray field measurements, were performed on a range of coil topologies and layered configurations. The resulting data provided information relating sensor performance to positioning of the amorphous element and its overall angular displacement. The main findings showed that inductance change was not frequency dependent in the range (20 – 100) kHz but decreased by up to 15% for large angular displacements when utilising a figure-of-eight coil design. The sensors developed in this work provide significantly better accuracy than current resistive-based flexible sensors. Further refinements to coil design and optimisation of the inductive element’s magnetic properties is expected to yield further improvements in sensor performance providing an excellent platform for future wearable technologies