    Suction Detection And Feedback Control For The Rotary Left Ventricular Assist Device

    Get PDF
    The Left Ventricular Assist Device (LVAD) is a rotary mechanical pump that is implanted in patients with congestive heart failure to help the left ventricle in pumping blood in the circulatory system. The rotary type pumps are controlled by varying the pump motor current to adjust the amount of blood flowing through the LVAD. One important challenge in using such a device is the desire to provide the patient with as close to a normal lifestyle as possible until a donor heart becomes available. The development of an appropriate feedback controller that is capable of automatically adjusting the pump current is therefore a crucial step in meeting this challenge. In addition to being able to adapt to changes in the patient\u27s daily activities, the controller must be able to prevent the occurrence of excessive pumping of blood from the left ventricle (a phenomenon known as ventricular suction) that may cause collapse of the left ventricle and damage to the heart muscle and tissues. In this dissertation, we present a new suction detection system that can precisely classify pump flow patterns, based on a Lagrangian Support Vector Machine (LSVM) model that combines six suction indices extracted from the pump flow signal to make a decision about whether the pump is not in suction, approaching suction, or in suction. The proposed method has been tested using in vivo experimental data based on two different LVAD pumps. The results show that the system can produce superior performance in terms of classification accuracy, stability, learning speed, iv and good robustness compared to three other existing suction detection methods and the original SVM-based algorithm. The ability of the proposed algorithm to detect suction provides a reliable platform for the development of a feedback control system to control the current of the pump (input variable) while at the same time ensuring that suction is avoided. Based on the proposed suction detector, a new control system for the rotary LVAD was developed to automatically regulate the pump current of the device to avoid ventricular suction. The control system consists of an LSVM suction detector and a feedback controller. The LSVM suction detector is activated first so as to correctly classify the pump status as No Suction (NS) or Suction (S). When the detection is “No Suction”, the feedback controller is activated so as to automatically adjust the pump current in order that the blood flow requirements of the patient’s body at different physiological states are met according to the patient’s activity level. When the detection is “Suction”, the pump current is immediately decreased in order to drive the pump back to a normal No Suction operating condition. The performance of the control system was tested in simulations over a wide range of physiological conditions

    Modeling andsimulationofspeedselectiononleftventricular assist devices

    Get PDF
    The control problem for LVADs is to set pump speed such that cardiac output and pressure perfusion are within acceptable physiological ranges. However, current technology of LVADs cannot provide for a closed-loop control scheme that can make adjustments based on the patient\u27s level of activity. In this context, the SensorART Speed Selection Module (SSM) integrates various hardware and software components in order to improve the quality of the patients\u27 treatment and the workflow of the specialists. It enables specialists to better understand the patient-device interactions, and improve their knowledge. The SensorART SSM includes two tools of the Specialist Decision Support System (SDSS); namely the Suction Detection Tool and the Speed Selection Tool. A VAD Heart Simulation Platform (VHSP) is also part of the system. The VHSP enables specialists to simulate the behavior of a patient?s circulatory system, using different LVAD types and functional parameters. The SDSS is a web-based application that offers specialists with a plethora of tools for monitoring, designing the best therapy plan, analyzing data, extracting new knowledge and making informative decisions. In this paper, two of these tools, the Suction Detection Tool and Speed Selection Tool are presented. The former allows the analysis of the simulations sessions from the VHSP and the identification of issues related to suction phenomenon with high accuracy 93%. The latter provides the specialists with a powerful support in their attempt to effectively plan the treatment strategy. It allows them to draw conclusions about the most appropriate pump speed settings. Preliminary assessments connecting the Suction Detection Tool to the VHSP are presented in this paper

    A New Development Of Feedback Controller For Left Ventricular Assist Device

    Get PDF
    The rotary Left Ventricular Assist Device (LVAD) is a mechanical pump surgically implanted in patients with end-stage congestive heart failure to help maintain the flow of blood from the sick heart. The rotary type pumps are controlled by varying the impeller speed to control the amount of blood flowing through the LVAD. One important challenge in using these devices is to prevent the occurrence of excessive pumping of blood from the left ventricle (known as suction) that may cause it to collapse due to the high pump speed. The development of a proper feedback controller for the pump speed is therefore crucial to meet this challenge. In this thesis, some theoretical and practical issues related to the development of such a controller are discussed. First, a basic nonlinear, time-varying cardiovascular-LVAD circuit model that will be used to develop the controller is reviewed. Using this model, a suction index is tested to detect suction. Finally we propose a feedback controller that uses the pump flow signal to regulate the pump speed based on the suction index and an associated threshold. The objective of this controller is to continuously update the pump speed to adapt to the physiological changes of the patient while at the same time avoiding suction. Simulation results are presented under different conditions of the patient activities. Robustness of the controller to measurement noise is also discussed

    Left Ventricular Assist Devices: Engineering Design Considerations

    Get PDF
    Patients with end-stage congestive heart failure awaiting heart transplantation often wait long periods of time (300 days or more on the average) before a suitable donor heart becomes available. The medical community has placed increased emphasis on the use of Left Ventricular Assist Devices or LVADs that can substitute for, or enhance, the function of the natural heart while the patient is waiting for the heart transplant (Poirier, 1997; Frazier & Myers, 1999). Essentially, a rotary LVAD is a pump that operates continuously directing blood from the left ventricle into the aorta by avoiding the aortic valve. Generally speaking, the goal of the LVAD is to assist the native heart in pumping blood through the circulatory system so as to provide the patient with as close to a normal lifestyle as possible until a donor heart becomes available or, in some cases, until the patient’s heart recovers. In many situations, this means allowing the patient to return home and/or to the workforce

    Left Ventricular Assist Devices: Engineering Design Considerations

    Get PDF
    Patients with end-stage congestive heart failure awaiting heart transplantation often wait long periods of time (300 days or more on the average) before a suitable donor heart becomes available. The medical community has placed increased emphasis on the use of Left Ventricular Assist Devices or LVADs that can substitute for, or enhance, the function of the natural heart while the patient is waiting for the heart transplant (Poirier, 1997; Frazier & Myers, 1999). Essentially, a rotary LVAD is a pump that operates continuously directing blood from the left ventricle into the aorta by avoiding the aortic valve. Generally speaking, the goal of the LVAD is to assist the native heart in pumping blood through the circulatory system so as to provide the patient with as close to a normal lifestyle as possible until a donor heart becomes available or, in some cases, until the patient’s heart recovers. In many situations, this means allowing the patient to return home and/or to the workforce

    Treatment-Specific Approaches for Analysis and Control of Left Ventricular Assist Devices

    Get PDF
    A Left Ventricular Assist Device (LVAD) is a mechanical pump that helps patients with heart failure conditions. This rotary pump works in parallel to the ailing heart and provides an alternative path for blood flow from the weak left ventricle to the aorta. The LVAD is controlled by the power supplied to the pump motor. An increase in the pump motor power increases the pump speed and the pump flow. The LVAD is typically controlled at a fixed setting of pump power. This basically means that the controller does not react to any change in the activity level of the patient. An important engineering challenge is to develop an LVAD feedback controller that can automatically adjusts its pump motor power so that the resulting pump flow matches the physiological demand of the patient. To this end, the development of a mathematical model that can be used to accurately simulate the interaction between the cardiovascular system of the patient and the LVAD is essential for the controller design. The use of such a dynamic model helps engineers and physicians in testing their theories, assessing the effectiveness of prescribed treatments, and understanding in depth the characteristics of this coupled bio-mechanical system. The first contribution of this dissertation is the development of a pump power-based model for the cardiovascular-LVAD system. Previously, the mathematical models in the literature assume availability of the pump speed as an independent control variable. In reality, however, the device is controlled by pump motor power which, in turn, produces the rotational pump speed. The nonlinear relationship between the supplied power and the speed is derived, and interesting observations about the pump speed signal are documented. The second contribution is the development of a feedback controller for patients using an LVAD as either a destination therapy or a bridge to transplant device. The main objective of designing this controller is to provide a physiological demand of the patient equivalent of that of a healthy individual. Since the device is implanted for a long period of time, this objective is chosen to allow the patient to live a life as close to normal as possible. The third contribution is an analysis of the aortic valve dynamics under the support of an LVAD. The aortic valve may experiences a permanent closure when the LVAD pump power is increased too much. The permanent closure of the aortic valve can be very harmful to the patients using the device as a bridge to recovery treatments. The analysis illustrates the various changes in the hemodynamic variables of the patient as a result of aortic valve closing. The results establish the relationship between the activity level and the heart failure severity with respect to the duration of the aortic valve opening

    Development and applications of in-vitro and in-silico models of the cardiovascular system to study the effects of mechanical circulatory support.

    Get PDF
    Cardiovascular diseases (CVDs) are the leading cause of mortality globally. With ongoing interest in CVDs treatment, preclinical models for drug/therapeutic development that allow for fast iterative research are needed. Owing to the inherent complexity of the cardiovascular system, current in-vitro models of the cardiovascular system fail to replicate many of the physiological aspects of the cardiovascular system. In this dissertation, the main concern is with heart failure (HF). In advanced HF, patients may receive Left Ventricular Assist Devices (LVADs) as a bridge to transplant or destination therapy. However, LVADs have many limitations, including inability to adapt to varying tissue demand conditions, risk of ventricular suction, and diminished arterial pulsatility. To address these issues, this dissertation aims to use and develop computer, cellular, and tissue models of the cardiovascular system. 1) Use an in-silico model of the cardiovascular system to develop a novel control algorithm for LVADs. The control system was rigorously tested and showed adequate perfusion during rest and exercise, protect against ventricular suction under reduced heart preload, and augment arterial pulsatility through pulse modulation without requiring sensor implantation or model-based estimations. 2) While pulsatility augmentation was feasible through the developed control algorithm, the pulse waveform that could normalize the vascular phenotype is unknown. To address this, an endothelial cell-smooth muscle cell microfluidic coculture model was developed to recreate the physiological mechanical stimulants in the vascular wall. The results demonstrated different effects of pulsatile shear stress and stretch on endothelial cells and may indicate that a pulse pressure of at least 30 mmHg is needed to maintain normal endothelial morphology. 3) In order to study the effects of mechanical unloading on the native ventricle, a novel cardiac tissue culture model (CTCM) was developed. CTCM provided physiological electromechanical and humoral stimulation with 25% preload stretch and thyroid and glucocorticoid treatment maintained the cardiac phenotype for 12 days. The device was thoroughly characterized and tested. Results demonstrated improved viability, energy utilization, fibrotic remodeling, and structural integrity compared to available culture systems. The system was also used to reproduce ventricular volume-overload and the results demonstrated hypertrophic and fibrotic remodeling, typical of volume-overload pathology
    • …