38 research outputs found

    Performance analysis of Ultra-wideband RF switch using discrete PIN diode in SC-79 package for medical application of microwave imaging

    Get PDF
    Microwave imaging is an emerging technology in the medical application which have similar functions as X-ray, Magnetic Resonance Imaging (MRI), and Computed Tomography scan (CT scan). In designing a microwave imaging system for medical application, it can use a monostatic radar approach by transmitting a Gaussian pulse (with an ultra-wideband (UWB) frequency). In this system, eight antennas are required with the support of RF switches. Thus, it is important to get the best performance of UWB RF switch in this application. Therefore, this paper presents the performance analysis of four different RF switch topologies (Design 1, 2, 3 and 4) using discrete PIN diode in SC-79 package. The design was based on single pole double throw (SPDT) switch. As result, Design 2 is the best topology after considering the tradeoff between isolation and return loss performances. Based on the three cascaded SPDT switches of Design 2, the insertion loss was less than -2 dB and return loss was more than -10 dB. Meanwhile, the isolation bandwidth (at the minimum isolation of -20 dB) was from 0.5 to 3.7 GHz (with 3.2 GHz bandwidth), hence, it could be used in the UWB frequency for medical application of microwave imaging

    Microwave Imaging Using CMOS Integrated Circuits with Rotating 4 × 4 Antenna Array on a Breast Phantom

    Get PDF
    A digital breast cancer detection system using 65 nm technology complementary metal oxide semiconductor (CMOS) integrated circuits with rotating 4 × 4 antenna array is presented. Gaussian monocycle pulses are generated by CMOS logic circuits and transmitted by a 4 × 4 matrix antenna array via two CMOS single-pole-eight-throw (SP8T) switching matrices. Radar signals are received and converted to digital signals by CMOS equivalent time sampling circuits. By rotating the 4 × 4 antenna array, the reference signal is obtained by averaging the waveforms from various positions to extract the breast phantom target response. A signal alignment algorithm is proposed to compensate the phase shift of the signals caused by the system jitter. After extracting the scattered signal from the target, a bandpass filter is applied to reduce the noise caused by imperfect subtraction between original and the reference signals. The confocal imaging algorithm for rotating antennas is utilized to reconstruct the breast image. A 1 cm3 bacon block as a cancer phantom target in a rubber substrate as a breast fat phantom can be detected with reduced artifacts

    Simulation and Design of an UWB Imaging System for Breast Cancer Detection

    Get PDF
    Breast cancer is the most frequently diagnosed cancer among women. In recent years, the mortality rate due to this disease is greatly decreased thanks to both enormous progress in cancer research, and screening campaigns which have allowed the increase in the number of early diagnoses of the disease. In fact, if the tumor is identied in its early stage, e.g. when it has a diameter of less than one centimeter, the possibility of a cure can reach 93%. However, statistics show that more young aged women are suered breast cancer. The goal of screening exams for early breast cancer detection is to nd cancers before they start to cause symptoms. Regular mass screening of all women at risk is a good option to achieve that. Instead of meeting very high diagnostic standards, it is expected to yield an early warning, not a denitive diagnosis. In the last decades, X-ray mammography is the most ecient screening technique. However, it uses ionizing radiation and, therefore, should not be used for frequent check-ups. Besides, it requires signicant breast compression, which is often painful. In this scenario many alternative technologies were developed to overcome the limitations of mammography. Among these possibilities, Magnetic Resonance Imaging (MRI) is too expensive and time-consuming, Ultrasound is considered to be too operatordependent and low specicity, which are not suitable for mass screening. Microwave imaging techniques, especially Ultra WideBand (UWB) radar imaging, is the most interesting one. The reason of this interest relies on the fact that microwaves are non-ionizing thus permitting frequent examinations. Moreover, it is potentially lowcost and more ecient for young women. Since it has been demonstrated in the literatures that the dielectric constants between cancerous and healthy tissues are quite dierent, the technique consists in illuminating these biological tissues with microwave radiations by one or more antennas and analyzing the re ected signals. An UWB imaging system consists of transmitters, receivers and antennas for the RF part, the transmission channel and of a digital backend imaging unit for processing the received signals. When an UWB pulse strikes the breast, the pulse is re ected due to the dielectric discontinuity in tissues, the bigger the dierence, the bigger the backscatter. The re ected signals are acquired and processed to create the energy maps. This thesis aims to develop an UWB system at high resolution for the detection of carcinoma breast already in its initial phase. To favor the adoption of this method in screening campaigns, it is necessary to replace the expensive and bulky RF instrumentation used so far with ad-hoc designed circuits and systems. In order to realize that, at the very beginning, the overall system environment must be built and veried, which mainly consists of the transmission channel{the breast model and the imaging unit. The used transmission channel data come from MRI of the prone patient. In order to correctly use this numerical model, a simulator was built, which was implemented in Matlab, according to the Finite-Dierence-Time- Domain (FDTD) method. FDTD algorithm solves the electric and magnetic eld both in time and in space, thus, simulates the propagation of electromagnetic waves in the breast model. To better understand the eect of the system non-idealities, two 2D breast models are investigated, one is homogeneous, the other is heterogeneous. Moreover, the modeling takes into account all critical aspects, including stability and medium dispersion. Given the types of tissues under examination, the frequency dependence of tissue dielectric properties is incorporated into wideband FDTD simulations using Debye dispersion parameters. A performed further study is in the implementation of the boundary conditions. The Convolution Perfectly Matched Layer (CPML) is used to implement the absorbing boundaries. The objective of the imaging unit is to obtain an energy map representing the amount of energy re ected from each point of the breast, by recombining the sampled backscattered signals. For this purpose, the study has been carried out on various beamforming in the literature. The basic idea is called as "delay and sum", which is to align the received signals in such a way as to focus a given point in space and then add up all the contributions, so as to obtain a constructive interference at that point if this is a diseased tissue. In this work, Microwave Imaging via Space Time (MIST) Beamforming algorithm is applied, which is based on the above principle and add more elaborations of the signals in order to make the algorithm less sensitive to propagation phenomena in the medium and to the non-idealities of the system. It is divided into two distinct steps: the rst step, called SKin Artifact Removal (SKAR), takes care of removing the contributions from the signal caused by the direct path between the transmitter and receiver, the re ection of skin, as they are orders of magnitude higher compared to the re ections caused by cancers; the second step, which is BEAmForming (BEAF), performs the algorithm of reconstruction by forming a weighted combination of time delayed version of the calibrated re ected signals. As discussed above, more attention must be paid on the implementation of the ad-hoc integration circuits. In this scenario, due to the strict requirements on the RF receiver component, two dierent approaches of the implementation of the RF front-end, Direct Conversion (DC) receiver and Coherent Equivalent Time Sampling (CETS) receiver are compared. They are modeled behaviorally and the eects of various impairments, such as thermal, jitter, and phase noise, as well as phase inaccuracies, non-linearity, ADC quantization noise and distortion, on energy maps and on quantitative metrics such as SCR and SMR are evaluated. Dierential Gaussian pulse is chosen as the exciting source. Results show that DC receiver performs higher sensitivity to phase inaccuracies, which makes it less robust than the CETS receiver. Another advantage of the CETS receiver is that it can work in time domain with UWB pulses, other than in frequency domain with stepped frequency continuous waves like the DC one, which reduces the acquisition time without impacting the performance. Based on the results of the behavioral simulations, low noise amplier (LNA) and Track and Hold Amplier (THA) can be regarded as the most critical parts for the proposed CETS receiver, as well as the UWB antenna. This work therefore focuses on their hardware implementations. The LNA, which shows critical performance limitation at bandwidth and noise gure of receiver, has been developed based on common-gate conguration. And the THA based on Switched Source Follower (SSF) scheme has been presented and improved to obtain high input bandwidth, high sampling rate, high linearity and low power consumption. LNA and THA are implemented in CMOS 130nm technology and the circuit performance evaluation has been taken place separately and together. The small size UWB wide-slot antenna is designed and simulated in HFSS. Finally, in order to evaluate the eect of the implemented transistor level components on system performance, a multi-resolution top-down system methodology is applied. Therfore, the entire ow is analyzed for dierent levels of the RF frontend. Initially the system components are described behaviorally as ideal elements. The main activity consists in the analysis and development of the entire frontend system, observing and complementing each other blocks in a single ow simulation, clear and well-dened in its various interfaces. To achieve that the receiver is modeled and analyzed using VHDL-AMS language block by block, moreover, the impact of quantization, noise, jitter, and non-linearity is also evaluated. At last, the behavioral description of antenna, LNA and THA is replaced with a circuit-level one without changing the rest of the system, which permits a system-level assessment of low-level issues

    Analysis and Design of Radio Frequency Integrated Circuits for Breast Cancer Radar Imaging in CMOS Technology

    Get PDF
    Breast cancer is by far the most incident tumor among female population. Early stage prevention is a key factor in delivering long term survival of breast cancer patients. X-ray mammography is the most commonly used diagnostic technique to detect non-palpable tumors. However, 10-30% of tumors are missed by mammography and ionizing radiations together with breast compression do not lead to comfort in patient treatment. In this context, ultrawideband microwave radar technology is an attractive alternative. It relies on the dielectric contrast of normal and malignant tissues at microwave frequencies to detect and locate tumors inside the breast. This work presents the analysis and design of radio frequency integrated circuits for breast cancer imaging in CMOS technology. The first part of the thesis concerns the system analysis. A behavioral model of two different transceiver architectures for UWB breast cancer imaging employing a SFCW radar system are presented. A mathematical model of the direct conversion and super heterodyne architectures together with a numerical breast phantom are developed. FDTD simulations data are used to on the behavioral model to investigate the limits of both architectures from a circuit-level point of view. Insight is given into I/Q phase inaccuracies and their impact on the quality of the final reconstructed images. The result is that the simplicity of the direct conversion architecture makes the receiver more robust toward the critical impairments for this application. The second part of the thesis is dedicated to the circuit design. The main achievement is a 65nm CMOS 2-16GHz stepped frequency radar transceiver for medical imaging. The RX features 36dB conversion gain, >29dBm compression point, 7dB noise figure, and 30Hz 1/f noise corner. The TX outputs 14dBm with >40dBc harmonic rejection and <109dBc/Hz phase noise at 1MHz offset. Overall power dissipation is 204mW from 1.2V supply. The radar achieves 3mm resolution within the body, and 107dB dynamic range, a performance enabling the use for breast cancer diagnostic imaging. To further assess the capabilities of the proposed radar, a physical breast phantom was synthesized and two targets mimicking two tumors were buried inside the breast. The targets are clearly identified and correctly located, effectively proving the performance of the designed radar as a possible tool for breast cancer detection

    GigaHertz Symposium 2010

    Get PDF

    Design of Fully-Integrated High-Resolution Radars in CMOS and BiCMOS Technologies

    Get PDF
    The RADAR, acronym that stands for RAdio Detection And ranging, is a device that uses electromagnetic waves to detect the presence and the distance of an illuminated target. The idea of such a system was presented in the early 1900s to determine the presence of ships. Later on, with the approach of World War II, the radar gained the interest of the army who decided to use it for defense purposes, in order to detect the presence, the distance and the speed of ships, planes and even tanks. Nowadays, the use of similar systems is extended outside the military area. Common applications span from weather surveillance to Earth composition mapping and from flight control to vehicle speed monitoring. Moreover, the introduction of new ultrawideband (UWB) technologies makes it possible to perform radar imaging which can be successfully used in the automotive or medical field. The existence of a plenty of known applications is the reason behind the choice of the topic of this thesis, which is the design of fully-integrated high-resolution radars. The first part of this work gives a brief introduction on high resolution radars and describes its working principle in a mathematical way. Then it gives a comparison between the existing radar types and motivates the choice of an integrated solution instead of a discrete one. The second part concerns the analysis and design of two CMOS high-resolution radar prototypes tailored for the early detection of the breast cancer. This part begins with an explanation of the motivations behind this project. Then it gives a thorough system analysis which indicates the best radar architecture in presence of impairments and dictates all the electrical system specifications. Afterwards, it describes in depth each block of the transceivers with particular emphasis on the local oscillator (LO) generation system which is the most critical block of the designs. Finally, the last section of this part presents the measurement results. In particular, it shows that the designed radar operates over 3 octaves from 2 to 16GHz, has a conversion gain of 36dB, a flicker-noise-corner of 30Hz and a dynamic range of 107dB. These characteristics turn into a resolution of 3mm inside the body, more than enough to detect even the smallest tumor. The third and last part of this thesis focuses on the analysis and design of some important building blocks for phased-array radars, including phase shifter (PHS), true time delay (TTD) and power combiner. This part begins with an exhaustive introduction on phased array systems followed by a detailed description of each proposed lumped-element block. The main features of each block is the very low insertion loss, the wideband characteristic and the low area consumption. Finally, the major effects of circuit parasitics are described followed by simulation and measurement results

    Advanced Microwave Circuits and Systems

    Get PDF

    Design and analysis of wideband passive microwave devices using planar structures

    Get PDF
    A selected volume of work consisting of 84 published journal papers is presented to demonstrate the contributions made by the author in the last seven years of his work at the University of Queensland in the area of Microwave Engineering. The over-arching theme in the author’s works included in this volume is the engineering of novel passive microwave devices that are key components in the building of any microwave system. The author’s contribution covers innovative designs, design methods and analyses for the following key devices and associated systems: Wideband antennas and associated systems Band-notched and multiband antennas Directional couplers and associated systems Power dividers and associated systems Microwave filters Phase shifters Much of the motivation for the work arose from the desire to contribute to the engineering o
    corecore