992 research outputs found
Four-dimensional tomographic reconstruction by time domain decomposition
Since the beginnings of tomography, the requirement that the sample does not
change during the acquisition of one tomographic rotation is unchanged. We
derived and successfully implemented a tomographic reconstruction method which
relaxes this decades-old requirement of static samples. In the presented
method, dynamic tomographic data sets are decomposed in the temporal domain
using basis functions and deploying an L1 regularization technique where the
penalty factor is taken for spatial and temporal derivatives. We implemented
the iterative algorithm for solving the regularization problem on modern GPU
systems to demonstrate its practical use
Four-dimensional Cone Beam CT Reconstruction and Enhancement using a Temporal Non-Local Means Method
Four-dimensional Cone Beam Computed Tomography (4D-CBCT) has been developed
to provide respiratory phase resolved volumetric imaging in image guided
radiation therapy (IGRT). Inadequate number of projections in each phase bin
results in low quality 4D-CBCT images with obvious streaking artifacts. In this
work, we propose two novel 4D-CBCT algorithms: an iterative reconstruction
algorithm and an enhancement algorithm, utilizing a temporal nonlocal means
(TNLM) method. We define a TNLM energy term for a given set of 4D-CBCT images.
Minimization of this term favors those 4D-CBCT images such that any anatomical
features at one spatial point at one phase can be found in a nearby spatial
point at neighboring phases. 4D-CBCT reconstruction is achieved by minimizing a
total energy containing a data fidelity term and the TNLM energy term. As for
the image enhancement, 4D-CBCT images generated by the FDK algorithm are
enhanced by minimizing the TNLM function while keeping the enhanced images
close to the FDK results. A forward-backward splitting algorithm and a
Gauss-Jacobi iteration method are employed to solve the problems. The
algorithms are implemented on GPU to achieve a high computational efficiency.
The reconstruction algorithm and the enhancement algorithm generate visually
similar 4D-CBCT images, both better than the FDK results. Quantitative
evaluations indicate that, compared with the FDK results, our reconstruction
method improves contrast-to-noise-ratio (CNR) by a factor of 2.56~3.13 and our
enhancement method increases the CNR by 2.75~3.33 times. The enhancement method
also removes over 80% of the streak artifacts from the FDK results. The total
computation time is ~460 sec for the reconstruction algorithm and ~610 sec for
the enhancement algorithm on an NVIDIA Tesla C1060 GPU card.Comment: 20 pages, 3 figures, 2 table
Enhancing Compressed Sensing 4D Photoacoustic Tomography by Simultaneous Motion Estimation
A crucial limitation of current high-resolution 3D photoacoustic tomography
(PAT) devices that employ sequential scanning is their long acquisition time.
In previous work, we demonstrated how to use compressed sensing techniques to
improve upon this: images with good spatial resolution and contrast can be
obtained from suitably sub-sampled PAT data acquired by novel acoustic scanning
systems if sparsity-constrained image reconstruction techniques such as total
variation regularization are used. Now, we show how a further increase of image
quality can be achieved for imaging dynamic processes in living tissue (4D
PAT). The key idea is to exploit the additional temporal redundancy of the data
by coupling the previously used spatial image reconstruction models with
sparsity-constrained motion estimation models. While simulated data from a
two-dimensional numerical phantom will be used to illustrate the main
properties of this recently developed
joint-image-reconstruction-and-motion-estimation framework, measured data from
a dynamic experimental phantom will also be used to demonstrate their potential
for challenging, large-scale, real-world, three-dimensional scenarios. The
latter only becomes feasible if a carefully designed combination of tailored
optimization schemes is employed, which we describe and examine in more detail
Accelerated High-Resolution Photoacoustic Tomography via Compressed Sensing
Current 3D photoacoustic tomography (PAT) systems offer either high image
quality or high frame rates but are not able to deliver high spatial and
temporal resolution simultaneously, which limits their ability to image dynamic
processes in living tissue. A particular example is the planar Fabry-Perot (FP)
scanner, which yields high-resolution images but takes several minutes to
sequentially map the photoacoustic field on the sensor plane, point-by-point.
However, as the spatio-temporal complexity of many absorbing tissue structures
is rather low, the data recorded in such a conventional, regularly sampled
fashion is often highly redundant. We demonstrate that combining variational
image reconstruction methods using spatial sparsity constraints with the
development of novel PAT acquisition systems capable of sub-sampling the
acoustic wave field can dramatically increase the acquisition speed while
maintaining a good spatial resolution: First, we describe and model two general
spatial sub-sampling schemes. Then, we discuss how to implement them using the
FP scanner and demonstrate the potential of these novel compressed sensing PAT
devices through simulated data from a realistic numerical phantom and through
measured data from a dynamic experimental phantom as well as from in-vivo
experiments. Our results show that images with good spatial resolution and
contrast can be obtained from highly sub-sampled PAT data if variational image
reconstruction methods that describe the tissues structures with suitable
sparsity-constraints are used. In particular, we examine the use of total
variation regularization enhanced by Bregman iterations. These novel
reconstruction strategies offer new opportunities to dramatically increase the
acquisition speed of PAT scanners that employ point-by-point sequential
scanning as well as reducing the channel count of parallelized schemes that use
detector arrays.Comment: submitted to "Physics in Medicine and Biology
Distributed optimization for nonrigid nano-tomography
Resolution level and reconstruction quality in nano-computed tomography
(nano-CT) are in part limited by the stability of microscopes, because the
magnitude of mechanical vibrations during scanning becomes comparable to the
imaging resolution, and the ability of the samples to resist beam damage during
data acquisition. In such cases, there is no incentive in recovering the sample
state at different time steps like in time-resolved reconstruction methods, but
instead the goal is to retrieve a single reconstruction at the highest possible
spatial resolution and without any imaging artifacts. Here we propose a joint
solver for imaging samples at the nanoscale with projection alignment,
unwarping and regularization. Projection data consistency is regulated by dense
optical flow estimated by Farneback's algorithm, leading to sharp sample
reconstructions with less artifacts. Synthetic data tests show robustness of
the method to Poisson and low-frequency background noise. Applicability of the
method is demonstrated on two large-scale nano-imaging experimental data sets.Comment: Manuscript and supplementary materia
Fast 4D tensile test monitored via X-CT: Single projection based Digital Volume Correlation dedicated to slender samples
International audienceThe measurement of 4D (i.e., 3D space and time) displacement fields of in situ tests within X-ray Computed Tomography scanners (i.e., lab-scale X-CT) is considered herein using projection-based Digital Volume Correlation. With one single projection per loading (i.e. time) step, the developed method allows for loading not to be interrupted and to vary continuously during the scan rotation. As a result, huge gains in acquisition time (i.e., more than two orders of magnitudes) to be reached. The kinematic analysis is carried out using predefined space and time bases combined with model reduction techniques (i.e., Proper Generalized Decomposition with space-time decomposition). The accuracy of the measured kinematic basis is assessed via gray level residual fields. An application to an in situ tensile test composed of 127 time steps is performed. Because of the slender geometry of the sample, a specific beam space regularization is used, which is composed of a stack of rigid sections. Large improvements on the residual, whose SNR evolves from 9.9 dB to 26.7 dB, validate the procedure
- …