7,225 research outputs found

    The Local Field Potential Reflects Surplus Spike Synchrony

    Get PDF
    The oscillatory nature of the cortical local field potential (LFP) is commonly interpreted as a reflection of synchronized network activity, but its relationship to observed transient coincident firing of neurons on the millisecond time-scale remains unclear. Here we present experimental evidence to reconcile the notions of synchrony at the level of neuronal spiking and at the mesoscopic scale. We demonstrate that only in time intervals of excess spike synchrony, coincident spikes are better entrained to the LFP than predicted by the locking of the individual spikes. This effect is enhanced in periods of large LFP amplitudes. A quantitative model explains the LFP dynamics by the orchestrated spiking activity in neuronal groups that contribute the observed surplus synchrony. From the correlation analysis, we infer that neurons participate in different constellations but contribute only a fraction of their spikes to temporally precise spike configurations, suggesting a dual coding scheme of rate and synchrony. This finding provides direct evidence for the hypothesized relation that precise spike synchrony constitutes a major temporally and spatially organized component of the LFP. Revealing that transient spike synchronization correlates not only with behavior, but with a mesoscopic brain signal corroborates its relevance in cortical processing.Comment: 45 pages, 8 figures, 3 supplemental figure

    Active C4 electrodes for local field potential recording applications

    Get PDF
    Extracellular neural recording, with multi-electrode arrays (MEAs), is a powerful method used to study neural function at the network level. However, in a high density array, it can be costly and time consuming to integrate the active circuit with the expensive electrodes. In this paper, we present a 4 mm × 4 mm neural recording integrated circuit (IC) chip, utilizing IBM C4 bumps as recording electrodes, which enable a seamless active chip and electrode integration. The IC chip was designed and fabricated in a 0.13 μm BiCMOS process for both in vitro and in vivo applications. It has an input-referred noise of 4.6 μV rms for the bandwidth of 10 Hz to 10 kHz and a power dissipation of 11.25 mW at 2.5 V, or 43.9 μW per input channel. This prototype is scalable for implementing larger number and higher density electrode arrays. To validate the functionality of the chip, electrical testing results and acute in vivo recordings from a rat barrel cortex are presented.R01 NS072385 - NINDS NIH HHS; 1R01 NS072385 - NINDS NIH HH

    Frequency dependence of signal power and spatial reach of the local field potential

    Get PDF
    The first recording of electrical potential from brain activity was reported already in 1875, but still the interpretation of the signal is debated. To take full advantage of the new generation of microelectrodes with hundreds or even thousands of electrode contacts, an accurate quantitative link between what is measured and the underlying neural circuit activity is needed. Here we address the question of how the observed frequency dependence of recorded local field potentials (LFPs) should be interpreted. By use of a well-established biophysical modeling scheme, combined with detailed reconstructed neuronal morphologies, we find that correlations in the synaptic inputs onto a population of pyramidal cells may significantly boost the low-frequency components of the generated LFP. We further find that these low-frequency components may be less `local' than the high-frequency LFP components in the sense that (1) the size of signal-generation region of the LFP recorded at an electrode is larger and (2) that the LFP generated by a synaptically activated population spreads further outside the population edge due to volume conduction

    Local field potential measurement with low-power analog integrated circuit

    Get PDF
    Journal ArticleLocal field potentials (LFPs) in the brain are an important source of information for basic research and clinical (i.e., neuroprosthetic) applications. The energy contained in certain bands of LFPs in the 10-100 Hz range has been shown to correlate with specific arm movement parameters in nonhuman primates. In the near future, implantable devices will need to transmit neural information from hundreds of microelectrodes, and transcutaneous data transfer will become a significant bottleneck. Here we present a low-power, fully integrated circuit that performs on-site data reduction by isolating LFPs and measuring their signal energy. The resulting analog VLSI circuit consumes 586 μm × 79 μm of silicon area and dissipates only 5 nanowatts of power. We show that the chip performs similarly to state-of-the-art signal processing algorithms

    Spatial Resolution of Local Field Potential Signals in Macaque V4

    Full text link
    A main challenge for the development of cortical visual prostheses is to spatially localize individual spots of light, called phosphenes, by assigning appropriate stimulating parameters to implanted electrodes. Imitating the natural responses to phosphene-like stimuli at different positions can help in designing a systematic procedure to determine these parameters. The key characteristic of such a system is the ability to discriminate between responses to different positions in the visual field. While most previous prosthetic devices have targeted the primary visual cortex, the extrastriate cortex has the advantage of covering a large part of the visual field with a smaller amount of cortical tissue, providing the possibility of a more compact implant. Here, we studied how well ensembles of Multiunit activity (MUA) and Local Field Potentials (LFPs) responses from extrastriate cortical visual area V4 of a behaving macaque monkey can discriminate between two-dimensional spatial positions. We found that despite the large receptive field sizes in V4, the combined responses from multiple sites, whether MUA or LFP, has the capability for fine and coarse discrimination of positions. We identified a selection procedure that could significantly increase the discrimination performance while reducing the required number of electrodes. Analysis of noise correlation in MUA and LFP responses showed that noise correlations in LFP responses carry more information about the spatial positions. Overall, these findings suggest that spatial positions could be localized with patterned stimulation in extrastriate area V4

    Chronic neural probe for simultaneous recording of single-unit, multi-unit, and local field potential activity from multiple brain sites

    Get PDF
    Drug resistant focal epilepsy can be treated by resecting the epileptic focus requiring a precise focus localization using stereoelectroencephalography (SEEG) probes. As commercial SEEG probes offer only a limited spatial resolution, probes of higher channel count and design freedom enabling the incorporation of macro and microelectrodes would help increasing spatial resolution and thus open new perspectives for investigating mechanisms underlying focal epilepsy and its treatment. This work describes a new fabrication process for SEEG probes with materials and dimensions similar to clinical probes enabling recording single neuron activity at high spatial resolution. Polyimide is used as a biocompatible flexible substrate into which platinum electrodes and leads are... The resulting probe features match those of clinically approved devices. Tests in saline solution confirmed the probe stability and functionality. Probes were implanted into the brain of one monkey (Macaca mulatta), trained to perform different motor tasks. Suitable configurations including up to 128 electrode sites allow the recording of task-related neuronal signals. Probes with 32 and 64 electrode sites were implanted in the posterior parietal cortex. Local field potentials and multi-unit activity were recorded as early as one hour after implantation. Stable single-unit activity was achieved for up to 26 days after implantation of a 64-channel probe. All recorded signals showed modulation during task execution. With the novel probes it is possible to record stable biologically relevant data over a time span exceeding the usual time needed for epileptic focus localization in human patients. This is the first time that single units are recorded along cylindrical polyimide probes chronically implanted 22 mm deep into the brain of a monkey, which suggests the potential usefulness of this probe for human applications
    corecore