    Spectral matrix methods for partitioning power grids: Applications to the Italian and Floridian high-voltage networks

    Get PDF
    Intentional islanding is used to limit cascading power failures by isolating highly connected "islands" with local generating capacity. To efficiently isolate an island, one should break as few power lines as possible. This is a graph partitioning problem, and here we give preliminary results on islanding of the Italian and Floridian high-voltage grids by spectral matrix methods.Comment: 4 pages, 2 figures

    A Policy Switching Approach to Consolidating Load Shedding and Islanding Protection Schemes

    Full text link
    In recent years there have been many improvements in the reliability of critical infrastructure systems. Despite these improvements, the power systems industry has seen relatively small advances in this regard. For instance, power quality deficiencies, a high number of localized contingencies, and large cascading outages are still too widespread. Though progress has been made in improving generation, transmission, and distribution infrastructure, remedial action schemes (RAS) remain non-standardized and are often not uniformly implemented across different utilities, ISOs, and RTOs. Traditionally, load shedding and islanding have been successful protection measures in restraining propagation of contingencies and large cascading outages. This paper proposes a novel, algorithmic approach to selecting RAS policies to optimize the operation of the power network during and after a contingency. Specifically, we use policy-switching to consolidate traditional load shedding and islanding schemes. In order to model and simulate the functionality of the proposed power systems protection algorithm, we conduct Monte-Carlo, time-domain simulations using Siemens PSS/E. The algorithm is tested via experiments on the IEEE-39 topology to demonstrate that the proposed approach achieves optimal power system performance during emergency situations, given a specific set of RAS policies.Comment: Full Paper Accepted to PSCC 2014 - IEEE Co-Sponsored Conference. 7 Pages, 2 Figures, 2 Table

    Assessment of unintentional islanding operations in distribution networks with large induction motors

    Get PDF
    This paper is aimed at assessing the impact of unintentional islanding operations (IOs) in the presence of large induction motors (IMs) within distribution networks (DNs). When a fault occurs,followingthecircuitbreaker(CB)faultclearing,theIMsacttransientlyasgenerators,duetoits inertia, until the CB reclosing takes place. The present work is the outcome of a project carried out in a small DN, where ¿eld measurements were recorded over two years. This paper provides a detailed description of the test system, a selected list of ¿eld measurements, and a discussion on modeling guidelinesusedtocreatethemodeloftheactualpowersystem. Themaingoalistovalidatethesystem model by comparing ¿eld measurements with simulation results. The comparison of simulations and ¿eld measurements prove the appropriateness of the modeling guidelines used in this work and highlight the high accuracy achieved in the implemented three-phase Matlab/Simulink modelPostprint (published version

    The effect of inrush transients on pv inverter's grid impedance measurement based on inter-harmonic injection

    Get PDF
    This paper addresses a cause for false tripping of photovoltaic inverters with antiislanding protection based on impedance measurement with inter-harmonic injection. Earlier discussions about tripping problems happening when several devices are doing the measurement at the same time are supplemented with a problem caused by inrush transients of nearby devices. A series of experiments was conducted in the Power Quality laboratory of the TU/e, on a PV inverter which complies with the DIN VDE 0126 standard. Impedance measurement was done in parallel with the inverter and measurement results are presented. A criterion for false tripping caused by transients is explored. Also, influences of network impedance and grid harmonic pollution on false tripping were analyzed. In the end, some signal processing techniques are proposed to avoid this problem
    corecore