8,501 research outputs found

    Impacts of Radar Echoes on Internal Calibration Signals in the TerraSAR-X Instrument

    Get PDF
    For calibrating and monitoring the required radiometric stability, the radar instrument of TerraSAR-X features an internal calibration facility coupling into an additional port of the TRMs. Calibration pulses are routed through the front-end to characterise critical elements and parameters of the transmit (TX) and receive (RX) path. Changes in the signal path appear due to thermal effects, degradation, or extreme conditions in space. Especially the front-end TRMs controlling the phased array antenna are of crucial significance for the instrument reliability. There are many indications that the interference of the RX-Calibration signals is caused by an echo from a transmitted TerraSAR-X chirp pulse of the same data take. As consequently implemented in the TerraSAR-X system, different approaches solve these effects of signal interference. In orbit, the commanding sequence can be optimised for avoiding interference. At processing level, averaging techniques minimise the noise effects inside the calibration signals. This paper presents the effects of the radar echoes on the whole internal calibration process and how they can be detected and minimised

    Effect of Temperature on PH Meter Based on Arduino Uno with Internal Calibration

    Full text link
    PH Meter is a device used to express the level of acidity or basicity possessed by a substance or solution. Normal pH has a value of 7 while the pH value> 7 indicates that the substance has alkaline properties while the pH value <7 indicates acidic properties. pH 0 shows a high degree of acidity, and pH 14 shows the highest degree of alkalinity. pH Meter reads the pH and temperature values ​​in a sample. The author uses glass electrodes as a pH sensor, DS18B20 as a temperature sensor and LCD to make pH and temperature values. This module is equipped with an internal calibration that is used to set the module to read the pH value properly and correctly using a pH buffer and equipped with internal storage and this module facilitates battery usage. Based on pH measurements on the module the error value in buffer 4 calibration is 5.39%, in buffer 7 is 1.76%, in buffer 10 is 1.04%. The highest error value in the measurement sample is 3.54% and the lowest error value is 0.03%. The temperature of the sample is very influential on the reading of the pH value because the higher the temperature the pH value also increases even though it is not so significant

    Pulse-based internal calibration of polarimetric SAR

    Get PDF

    Spectroradiometric calibration of the Thematic Mapper and multispectral scanner system

    Get PDF
    The eleventh quarterly report on Spectroradiometric Calibration of the Thematic Mapper (Contract NAS5-27832) discusses calibrations made at White Sands on 24 May 1985. An attempt is made to standardize test results. Critical values used in the final steps of the data reduction and the comparison of the results of the pre-flight and internal calibration (IC) data are summarized

    A Radio--Optical Reference Frame VIII. CCD observations from KPNO and CTIO: internal calibration and first results

    Full text link
    In this pilot investigation, precise optical positions in the FK5 system are presented for a set of 16 compact extragalactic radio sources, which will be part of the future radio--optical reference frame. The 0.9 m KPNO and CTIO telescopes equipped with 2K CCD's have been used for this project. The astrometric properties of these instruments are investigated in detail. New techniques of using wide field CCD observations for astrometry in general are developed. An internal precision of 5 to 31 mas in position per single exposure is found, depending on the brightness of the object. The tie to the primary optical reference system is established by photographic astrometry using dedicated astrographs on both hemispheres. An accuracy of ≈30\approx 30 mas per source is estimated for the multi--step reduction procedure when based on the future Hipparcos catalog, while the FK5--based positions suffer from system errors of 100 to 200 mas as compared to the radio positions. This work provides a contribution to the international effort to link the Hipparcos instrumental coordinate system to the quasi--inertial VLBI radio reference frame. Precise radio and optical astrometry of a large sample of compact extragalactic sources will also contribute to the astrophysics of these objects by comparing the respective centers of emission at the optical and radio wavelengths.Comment: AAS v.4 LaTeX, 2 parts on 1 file (main text + deluxetable), accepted by AJ, Dec.95, fig. with reprint
    • …
    corecore