2,066 research outputs found

    Knowledge, attitude and perception on radiation imaging among children's caregivers in the pediatric dental clinic

    Full text link
    OBJECTIVE: Nuclear medicine provides important clinical information for diagnostic and therapeutic purposes. Use of medical imaging has gradually increased in the United States and this has raised health concerns about the potential future risks associated with radiation exposure in children. While studies have evaluated the adverse effects of imaging procedures, there is insufficient evidence about communicating radiation risks. The overall purpose of this paper is to review radiation risks in pediatric imaging using published evidence by the World Health Organization and to evaluate the knowledge and attitude of caregivers towards radiation risks in pediatric imaging. Specifically, we aim to determine whether an educational brochure improves parental knowledge of radiation and/or changes in attitude and perception to allow their children to undergo dental radiographs. METHODS: A prospective sample survey was performed of caregivers who presented with their child to the Boston University Pediatric Oral Healthcare Center. Parents or legal guardians (18 years or older) who accompanied a child were eligible for inclusion and approached for enrollment. Pre- and post-survey questionnaires were used to evaluate parents’ or guardians’ level of knowledge and attitude about the risks and benefits of dental radiographs. Parents were also asked their comfort level to allow their child to undergo dental radiographs. After completing the pre-survey questionnaire, parents were asked to read the English-language informational handout. Statistical analysis was performed through Microsoft Excel 2013. Descriptive analysis was conducted to summarize the survey responses. RESULTS: Among 30 parents who were surveyed, a small proportion (30%) of parents were very comfortable with dentist using dental radiographs on their child, versus 57% after reading the handout. Results showed that the informational handout improved the parental knowledge of risks and benefits of ionizing radiation. Most parents indicated that the handout was helpful and they reported increased level of comfort and willingness in their children receiving radiation imaging during dental treatment procedures. DISCUSSION: Educating parents or caregivers through an informational handout is a helpful resource in improving their knowledge and in relieving their concerns. Informing parents about the risks of ionizing radiation does not change parental willingness for their children to undergo dental radiographs

    Measuring the dose�width product and proposing the local diagnostic reference level in panoramic dental radiography: a multi-center study from Iran

    Get PDF
    Objective: Although radiation exposure associated with dental radiography is relatively low, patient exposure must be kept practically low. Therefore, it is necessary for each country to establish its own diagnostic reference levels (DRLs) suitable for its equipment and practice. In the present study, dose-width product (DWP) values for panoramic dental radiography were measured and a local DRL was established. Methods: Five panoramic devices from five radiology clinics of Kashan, Iran were selected to measure the DWP values of panoramic dental radiography. To investigate the DWP values, the parameters of each patient�s exposure (e.g., tube voltage, tube current, and exposure time) at these five radiology clinics were extracted. Then, the dose value received by each patient was measured based on a CT pencil chamber. Finally, the overall median DWP values for the patients with small, medium, and large sizes were obtained, and these values were considered as the local DRLs for panoramic dental radiography. Results: A total of 99 adult patients were included in the present study. The findings demonstrated that the median and third-quartile DWP values for these five radiology clinics ranged from 42.3 to 94.3 and 49.7 to 142.8 mGy mm, respectively. The local DRL values, which were established as the overall median DWP values, were 43.4, 52.0, and 80.3 mGy mm for the adults with small, medium, and large sizes, respectively. Conclusion: The local DRL proposed in this study for the adult with standard/medium size was lower than those proposed by other reports and seemed acceptable for panoramic radiography in Kashan, Iran. © 2020, Japanese Society for Oral and Maxillofacial Radiology and Springer Nature Singapore Pte Ltd

    Dental radiography: Embarrassing foreign objects

    Get PDF

    Lead X-Ray Vests: Pros and Cons in Dental Radiography and Patient Education on Radiographic Technology

    Get PDF
    Problem: There is a greater need to emphasize and educate patients and providers about radiologic advancements and patient exposure. The tradition of placing lead x-ray vests on patients for all radiographs is no longer a necessity. Without the explanation of why lead aprons are no longer needed, unnecessary steps for the provider and potential harm to the patient could be caused. Methods: This review of literature was assembled by analyzing data from primary and secondary sources through online databases. The most recent research on the risks and benefits of the use of lead x-ray vests towards patients in the dental office was examined. Articles included in this review were published within the last five years. Major Findings: Studies show the use of lead x-ray vests is widely obsolete with most new types of radiographic technology. Conclusions: Collimation and new digital radiographic devices have dramatically decreased patient radiation exposure by limiting the beam to a confined space on the patient\u27s oral cavity. There is also a risk that vests may pose a lead exposure hazard if not taken care of properly. The general patient population is widely unaware of these advancements in x-ray technology and of the ineffectiveness of lead aprons.https://scholarscompass.vcu.edu/denh_student/1020/thumbnail.jp

    The Importance of Dental Radiography

    Get PDF

    Medical image denoising using convolutional denoising autoencoders

    Full text link
    Image denoising is an important pre-processing step in medical image analysis. Different algorithms have been proposed in past three decades with varying denoising performances. More recently, having outperformed all conventional methods, deep learning based models have shown a great promise. These methods are however limited for requirement of large training sample size and high computational costs. In this paper we show that using small sample size, denoising autoencoders constructed using convolutional layers can be used for efficient denoising of medical images. Heterogeneous images can be combined to boost sample size for increased denoising performance. Simplest of networks can reconstruct images with corruption levels so high that noise and signal are not differentiable to human eye.Comment: To appear: 6 pages, paper to be published at the Fourth Workshop on Data Mining in Biomedical Informatics and Healthcare at ICDM, 201
    corecore